Industrial Air IL3106016 Operator's Manual

Single stage, belt drive, electric air compressors

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IL3106016 and is the answer not in the manual?

Questions and answers

Summary of Contents for Industrial Air IL3106016

  • Page 2 TABLE OF CONTENTS SAFETY GUIDELINES ......3 Shutdown ....... . .14 OVERVIEW .
  • Page 3: Safety Guidelines

    SAFETY GUIDELINES The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the following symbols. Please read the manual and pay attention to these sections. DANGER: – A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE. WARNING: –...
  • Page 12 MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO BELT TENSION AND PULLEY ALIGNMENT WARNING: To avoid personal injury, always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor. NOTE: Drive belt tensioning and pulley alignment are done at the same time.
  • Page 13: Pulley Alignment

    MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO PULLEY ALIGNMENT To check pulley alignment, remove the belt guard and place a straightedge (see A) against the pump flywheel (see B). Measure and record the distance from the straightedge to the edge of the drive belt at point C. Then measure the distance from the straightedge to the edge of the drive belt again at points D and E.
  • Page 14 MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO CLEANING THE AIR FILTER ENTREPOSAGE Avant d'entreposer le compresseur pour une période A dirty air filter will reduce the compressor’s performance prolongée, utilisez une soufflette pour nettoyer toute la and life. To avoid any internal contamination of the pump, the poussière et tous les débris du compresseur.
  • Page 15: Service Interval

    SERVICE INTERVAL Perform the following maintenance at the intervals indicated below. Inspect and clean air filter ..........Daily Check pump oil level .
  • Page 16: Troubleshooting Chart

    TROUBLESHOOTING CHART Note: Troubleshooting problems may have similar causes and solutions. PROBLEM POSSIBLE CAUSE SOLUTION Excessive current draw Low voltage/motor overload Check that power supply is adequate and that compressor is on a dedicated circuit. If using extension cord, try using without. If trips circuit breaker of motor reset switch compressor is connected to a circut protected by a fuse, use dual...
  • Page 17: Glossary Of Terms

    GLOSSARY OF TERMS ASME Cubic feet per minute; a unit of measure of air flow. American Society of Mechanical Engineers. Indicates that the components are manufactured, tested and inspected to the specifications set by ASME. Pounds per square inch; a unit of measure of air pressure. Kick-in pressure Factory set low pressure point that starts the compressor to Canadian Standards Association...

Table of Contents