SAFETY GUIDELINES The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the following symbols. Please read the manual and pay attention to these sections. – A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE. DANGER: WARNING: –...
TYPICAL INSTALLATION / INSTALLATION TYPIQUE / INSTALACION TIPICA TYPICAL INSTALLATION INSTALACION TIPICA Secadores de aire y post–enfriadores Air dryers and after coolers El secador de aire o el radiador de alida se instalan An air dryer or aftercooler is installed directly in the air line. directamente en la línea de aire.
COMPRESSOR CONTROLS / COMMANDES DU COMPRESSEUR / CONTROLES DEL COMPRESOR COMPRESSOR CONTROLS AVERTISSEMENT: Ne dépassez jamais la pression Refer to Fig. 3. maximum nominale de l'outil. PRESSURE switch (see A) Tournez le bouton dans le sens des aiguilles d'une montre This switch turns on the compressor.
MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO BELT TENSION AND PULLEY ALIGNMENT WARNING: To avoid personal injury, always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor. NOTE: Drive belt tensioning and pulley alignment are done at the same time.
Page 18
MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO CLEANING THE AIR FILTER ENTREPOSAGE Avant d'entreposer le compresseur pour une période A dirty air filter will reduce the compressor’s performance prolongée, utilisez une soufflette pour nettoyer toute la and life. To avoid any internal contamination of the pump, the poussière et tous les débris du compresseur.
SERVICE INTERVAL Perform the following maintenance at the intervals indicated below. Inspect and clean air filter ..........Daily Check pump oil level .
TROUBLESHOOTING CHART Note: Troubleshooting problems may have similar causes and solutions. PROBLEM POSSIBLE CAUSE SOLUTION Excessive current draw Low voltage/motor overload Check that power supply is adequate and that compressor is on a trips circuit breaker of dedicated circuit. If using extension cord, try using without. If motor reset switch compressor is connected to a circut protected by a fuse, use dual element time delay fuses (Buss Fusetron type “T”...
GLOSSARY OF TERMS ASME Cubic feet per minute; a unit of measure of air flow. American Society of Mechanical Engineers. Indicates that the components are manufactured, tested and inspected to the specifications set by ASME. Pounds per square inch; a unit of measure of air pressure. Kick-in pressure Factory set low pressure point that starts the compressor to Canadian Standards Association...