Industrial Air IPA1882054 Operator's Manual

Single stage, belt drive, electric air compressors

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPA1882054 and is the answer not in the manual?

Questions and answers

Summary of Contents for Industrial Air IPA1882054

  • Page 2 TABLE OF CONTENTS SAFETY GUIDELINES ......3 Daily Startup ......16 OVERVIEW .
  • Page 3: Safety Guidelines

    SAFETY GUIDELINES The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the following symbols. Please read the manual and pay attention to these sections. – A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE. DANGER: WARNING: –...
  • Page 7: Typical Installation

    TYPICAL INSTALLATION / INSTALLATION TYPIQUE / INSTALACION TIPICA TYPICAL INSTALLATION INSTALACION TIPICA Secadores de aire y post–enfriadores Air dryers and after coolers El secador de aire o el radiador de alida se instalan An air dryer or aftercooler is installed directly in the air line. directamente en la línea de aire.
  • Page 8: Compressor Controls

    COMPRESSOR CONTROLS / COMMANDES DU COMPRESSEUR / CONTROLES DEL COMPRESOR COMPRESSOR CONTROLS AVERTISSEMENT: Ne dépassez jamais la pression Refer to Fig. 3. maximum nominale de l'outil. PRESSURE switch (see A) Tournez le bouton dans le sens des aiguilles d'une montre This switch turns on the compressor.
  • Page 16: Maintenance \ Entretien \ Mantenimiento

    MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO BELT TENSION AND PULLEY ALIGNMENT WARNING: To avoid personal injury, always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor. NOTE: Drive belt tensioning and pulley alignment are done at the same time.
  • Page 18 MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO CLEANING THE AIR FILTER ENTREPOSAGE Avant d'entreposer le compresseur pour une période A dirty air filter will reduce the compressor’s performance prolongée, utilisez une soufflette pour nettoyer toute la and life. To avoid any internal contamination of the pump, the poussière et tous les débris du compresseur.
  • Page 19: Service Interval

    SERVICE INTERVAL Perform the following maintenance at the intervals indicated below. Inspect and clean air filter ..........Daily Check pump oil level .
  • Page 20: Troubleshooting Chart

    TROUBLESHOOTING CHART Note: Troubleshooting problems may have similar causes and solutions. PROBLEM POSSIBLE CAUSE SOLUTION Excessive current draw Low voltage/motor overload Check that power supply is adequate and that compressor is on a trips circuit breaker of dedicated circuit. If using extension cord, try using without. If motor reset switch compressor is connected to a circut protected by a fuse, use dual element time delay fuses (Buss Fusetron type “T”...
  • Page 21: Glossary Of Terms

    GLOSSARY OF TERMS ASME Cubic feet per minute; a unit of measure of air flow. American Society of Mechanical Engineers. Indicates that the components are manufactured, tested and inspected to the specifications set by ASME. Pounds per square inch; a unit of measure of air pressure. Kick-in pressure Factory set low pressure point that starts the compressor to Canadian Standards Association...
  • Page 22: Notes / Remarques / Notas

    NOTES / REMARQUES / NOTAS 200-2381...
  • Page 23 Made in USA with domestic and foreign components Fabriqué aux États Unis à l’aide de composants de l’intérieur et de l’étranger Hecho en EE.UU.con componentes domésticos y extranjeros © 2008 Sanborn Mfg. Division of MAT Industries, LLC. Springfield, MN 56087 1-888-895-4549 All Rights Reserved.