Differential pressure and the hour meter indicates when the filters and main Wavebrite™ filter module need changing, see Section 1.4 Check with Wave International technical department if in doubt. General Model Selections Guide: WBlite – Tenders and day boats. / WBS – Boats up to 20M.
Angles and fittings in hoses all cause a reduction in pump efficiency. • The shorter the pipe runs to and from the WAVEBRITE™ FILTER MODULE with no extra fittings such as elbows and bends, the better the system will perform. Always check with the Wave International Technical Department if in doubt.
WB16.rev08 Section 2. Tools and Fasteners Wavebrite™ can be installed with the average DIY toolkit. Items you will need: WARNING See Whale Pipe • Fixings/bolts for filter, pump and tank brackets. Fitting Guide • regarding the Whale Electrical connections, switches, fuses and wire. See Section 1.4 and Fig.2 WX 15mm pipe.
Page 5
WB16.rev08 Section 4. Wavebrite™ WBS Grey Water Filter System Specifications FLOW RATE: 1-15 Liters per min. SYSTEM MAX. PRESSURE: 6.2 bar. PRE-FILTERS MAX. DIFF. PRESSURE: 2 bar. (@ 2 bar. change cartridge) WAVEBRITE MODULE MAX. DIFF. PRESSURE: 4 bar. (@ 4 bar. change cartridge) MAX.
Page 6
If you have any terminated at a level above the overboard waste water discharge from the Wavebrite system doubts at any time and all grey waste drains. about installing this equipment, please consult a qualified person or contact Wave International for advice.
Page 7
WB16.rev08 Wavebrite™ WB2010 Grey Water Filter System. Replacement Cartridges: FLOW RATE: 1-15 Liters per min. SYSTEM MAX. PRESSURE: 6.2 bar. PRE-FILTERS MAX. DIFF. PRESSURE: 2 bar. (@ 2 bar. change cartridge) WAVEBRITE MODULE MAX. DIFF. PRESSURE: 4 bar. (@ 4 bar. change cartridge) MAX.
Page 8
WB16.rev08 Wavebrite™ WB2020 Grey Water Filter System. Replacement Cartridges: FLOW RATE: 1-15 Liters per min. SYSTEM MAX. PRESSURE: 6.2 bar. PRE-FILTERS MAX. DIFF. PRESSURE: 2 bar. (@ 2 bar. change cartridge) WAVEBRITE MODULE MAX. DIFF. PRESSURE: 4 bar. (@ 4 bar. change cartridge) MAX.
WB16.rev08 Section 5. Installing the Components Fitting WBS, WBLite, WB2010 & WB2020. See Fig. 1, 2, 3 & 4. • Locate a suitable position, refer to Section 1.4 and Fig.1, 2, 3 & 4, Note the Wavebrite™ CAUTION systems are modular and each component can be fitted remotely. Fix the mounting brackets It is advisable to use and saddle clamps.
WB16.rev08 Section 6. Cartridge Replacement IMPORTANT. Before replacing the cartridges ensure the pump is switched off and there WARNING is no pressure in the system. Before replacing the cartridges ensure • the pump is FILTER/STRAINER 1 (100 MICRON) screen requires cleaning periodically and should be switched off and part of a regular maintenance schedule.
Wave International limited makes no representations or warranties with respect to the contents or use of this manual and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Further, Wave International Limited reserves the right to revise this publication and make changes to its content, at any time and to make...
Need help?
Do you have a question about the wavebrite WBS and is the answer not in the manual?
Questions and answers