v Restore defaults
v Restart MM
General settings
General settings include:
v Management module name
v Name of the person who is responsible for the management module
v Physical location of the management module
v Real-time clock settings
Login profiles
You can specify up to 12 login profiles. For each login profile, specify the following:
v Login ID.
v Password.
v Authority. You can specify either read only (R/O) or read/write (R/W). The default
Alerts
For alerts, you can configure the following settings:
v Which alerts are monitored (from lists of Critical, Warning, and System alerts)
v Where and to whom alerts are sent
v How alerts are sent (SNMP or e-mail)
v How often to retry alert notification and the delay between retries
v Whether to include the event log with notifications
Port assignments
The following management-modules ports can be configured:
v HTTP
v HTTPS
v Telnet
v SSH
v SNMP Agent
v SNMP Traps
Network interfaces
You can configure the following two Ethernet interfaces:
v External network interface, which is the interface for the remote management and
v Internal network interface, which is the interface to the I/O modules.
Note: For I/O-module communication with a remote management station, through
76
BladeCenter T Types 8720 and 8730: Planning and Installation Guide
is read only.
console port.
the management-module external Ethernet port, the I/O module internal
network interface and the management module internal and external
interfaces must be on the same subnet.