Requirements For Installation Environment; Installation Requirements - Fujitsu XG0224 Hardware Manual

Hardware guide
Hide thumbs Also See for XG0224:
Table of Contents

Advertisement

XG0224 Hardware Guide
2.1
Requirements for Installation
Environment
Before installing the switch, please check the following:
Make sure that the switch and all the other options shown in this document are available for installation.
All the cables comply with the specifications of the interface connectors.
Warning
Do not connect cables to interface connectors other than those adaptable to the connector's
specifications.
Reference "1.1.1 Parts List" (pg.18)
Install the product under the following environmental conditions
2.1.1

Installation Requirements

Caution
Install the product under the following conditions. Using the product outside the required
environment may cause failure of the product.
Temperature and Humidity Requirements
Operation
Non-operation
Power Requirements
Item
Voltage
Frequency
Ground
Electricity
Inrush Current
Temperature (degrees C)
0 to 40
0 to 50
AC90V-264V
50Hz / 60Hz +2%, -4%
Separate ground wire from air conditioners and building, and D-class grounding with
ground resistance of 100 Ω or less.
80W
Maximum30A
Ensure installation environment that avoids lowering voltage to power supply
equipment at the time of power-on due to the inrush current, although there's no
impact from the inrush current in normal use.
Humidity (%RH)
15 to 85
8 to 90
Requirements
28
Chapter 2 Installation

Requirements for Installation Environment

Advertisement

Table of Contents
loading

Table of Contents