■ Performance
Storage Capacity
Data Transfer Rate (TAPE)
Burst Data Transfer Rate
Bit Error Rate
■ Operating Environment
Operating
Non-operating
■ Power Supply & Miscellaneous
Rated Power Supply
Case Dimensions
Mass
Equipment
40 GB uncompressed (with 186 m AIT-1 Turbo data
cartridge)
104 GB compressed (with 186 m AIT-1 Turbo data
cartridge
6 MB/s uncompressed (with AIT-1 Turbo data cartridge)
480 Mbps maximum (USB)
400 Mbps maximum (i.LINK)
less than 10
Temperature: 10 °C to 35 °C (∆T<10 °C/h)
Humidity:
Temperature: –40 °C to 70 °C (∆T<20 °C/h)
Humidity:
100 to 240 V AC, 50/60 Hz, 1.2 A
198 × 64.5 × 246 mm (W × H × D) (excluding projections)
2.4 kg
Quick start guide
AIT data cartridge
Operating instructions CD-ROM
USB 2.0 cable
i.LINK cables
Power cable
Warranty card
Safety regulations
Specifications may be subject to change, in the interest of technological
improvement, without notice or obligation.
*1
Assuming a 2.6:1 hardware compression ratio.
The actual degree of data compression during recording depends on the system environment
and type of data.
*1
)
-17
(50 °F to 95 °F (∆T<18 °F/h))
30 to 80% (non-condensing)
Maximum wet bulb temperature: 26 °C (78.8 °F)
(–40 °F to 158 °F (∆T<36 °F/h))
10 to 90% (∆RH<30%/h)
Maximum wet bulb temperature: 45 °C (113 °F)
(6-pin to 6-pin, 6-pin to 4-pin, 1 each)
1
1
1
1
2
1
1
1
31