Download Print this page

CPS Pro-Set TRS500E Series Owner's Manual

Oilless refrigerant

Advertisement

Quick Links

Pro-Set
TRS500E SERIES
®
Oilless Refrigerant Recovery System
OWNER'S MANUAL (English)
Français, Español, Deutsch and latest updates: www.cpsproducts.be
Series: TRS500E
TO BE OPERATED BY QUALIFIED PERSONNEL ONLY
Ignition proof design that meets UL1963
Supplement SB test methods of UL/ANSI 12.12.1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Pro-Set TRS500E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for CPS Pro-Set TRS500E Series

  • Page 1 Pro-Set TRS500E SERIES ® Oilless Refrigerant Recovery System OWNER’S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.be Series: TRS500E TO BE OPERATED BY QUALIFIED PERSONNEL ONLY Ignition proof design that meets UL1963 Supplement SB test methods of UL/ANSI 12.12.1...
  • Page 2 INTRODUCTION Efficient Everywhere! The TRS500E offers dual 110-240V operation with zero 50Hz degradation, ensuring consistent operation across frequencies. The Brushless Direct Current (BLDC) motor, with innovative wobble piston design, ensures maximum efficiency.
  • Page 3 BOX CONTENTS TRS500E Refrigerant Recovery Unit • 3m Locking Power Cord • Operational Manual • TABLE OF CONTENTS Introduction ........................2 Key Features ........................3 General Safety Instructions ..................4-6 Specifications ......................7 Unit Layout ........................8 Direct Vapor or Liquid Recovery .................9 Push - Pull Liquid Recovery ..................10 Routine Maintenance ....................11 Warranty ........................11 KEY FEATURES...
  • Page 4 GENERAL SAFETY INSTRUCTIONS Please read, follow and understand the contents of this entire manual, with special attention given to Danger, Warning and Caution statements. FOR USE BY PROFESSIONALLY TRAINED AND CERTIFIED OPERATORS ONLY. MOST STATES, COUNTRIES, ETC., MAY REQUIRE USER TO BE LICENSED. PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY.
  • Page 5 GENERAL SAFETY INSTRUCTIONS HAZARDOUS LOCATION SAFETY INSTRUCTIONS following additional safety recommendations when servicing HVAC&R equipment Hazardous location. These instructions do not replace existing occupational hazardous procedures or other local, state and/or federal agency regulations. Technicians working HVAC&R systems should have detailed knowledge and skills in handling refrigerants, personal protective equipment, refrigerant leak prevention, handling of cylinders, leak detection &...
  • Page 6 GENERAL SAFETY INSTRUCTIONS REFRIGERANT STORAGE CYLINDER SAFETY Check with your federal and/or state regulations on the proper vessel to store refrigerant. In the USA DOT CFR 40 is required when filling and transporting refrigerant storage vessels. This unit is design to be used with 400 PSIG rated storage vessels. In the USA, this is denoted by a DOT rating of 4ABA400 or 4BW400.
  • Page 7 Operating Temperature Range 0C to 50C 35cm x 22cm x 30cm Dimensions 10.0 kg. Weight * See CPS website for updated refrigerant list ARHI740-2016 Performance Data certified by UL High Temp. Vapor Rate Direct Vapor Direct Liquid Push - Pull Liquid Refrigerant 3.87 lb/min...
  • Page 8 TRS500E SERIES UNIT LAYOUT MANIFOLD VALVES AND POSITIONS FOR OPERATION The unit is designed with a manifold containing 3 ball valves for Recovery, Liquid Push-Pull, and Purge (Self-Clearing or Pump Down) operations. The following table shows the proper position for each ball valve vs. the Operation. IN Valve OUT Valve RECOVER/PURGE...
  • Page 9 DIRECT VAPOR OR LIQUID RECOVERY 1. Clean IN FILTER regularly. Note: If liquid refrigerant is present, 2. Connect RECOVERY MACHINE per compressor will emit a hammering diagram. sound. Use IN valve to regulate Note: The recovery tank must be incoming refrigerant until hammering rated for 38 bar.
  • Page 10 PUSH-PULL LIQUID RECOVERY 1. Connect the unit as shown in diagramm above. Note: The recovery tank must be rated for 38 bar. 2. Open both valves on Recovery Tank. 3. Open OUT valve on the Recovery unit. 4. Rotate the center valve to the PURGE position. 5.
  • Page 11 Fig 2 WARRANTY CPS Products, Inc. guarantees that all products are free of manufacturing and material defects to the original owner for one year from the date of purchase. If the equipment should fail during the guarantee period it will be repaired or replaced (at our option) at no charge. This guarantee does not apply to equipment that has been altered, misused or solely in need of field service maintenance.
  • Page 12 CPS PRODUCTS N.V Entrepotstraat 3 9100 Sint-Niklaas Belgium Tel: (323) 281 30 40 E-mail: info@cpsproducts.be Website: www.cpsproducts.be For latest update to this Owner's Manual, go to www.cpsproducts.com...