Hide thumbs Also See for SINTESI:

Advertisement

Quick Links

Installation Instructions
These instructions must be read
prior to installation
and use!
Pergola SINTESI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINTESI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hella SINTESI

  • Page 1 Installation Instructions These instructions must be read prior to installation and use! Pergola SINTESI...
  • Page 2: Table Of Contents

    Overview: Tools for the installation ..................5 Overview SINTESI........................ 6 Installation of the wall/ceiling brackets.................. 7 Installing the lateral/ceiling/wall bracket SINTESI FREE ............8 Installation on concrete ......................9 Installation on concrete 60-200 mm ETICS ................ 10 Installation on brickwork ..................... 11 Installation on brickwork 60-170 mm ETICS ...............
  • Page 3: Preliminary Remarks Hella Pergola Sintesi

    Preliminary remarks HELLA Pergola SINTESI With this HELLA product you have opted for a high-quality product with a most up-to-date technology that can nevertheless be easily installed and operated. In these instructions we describe the basic installation, commissioning and use.
  • Page 4: Before Installation

    Installation Instructions Before installation Check the product immediately for possible shipping damage and for com- pliance with the delivery receipt. If parts are missing or damaged, please consult your supplier immediately. Check the mounting base and ensure that the mounting material to be used complies with the given conditions to guarantee proper installation.
  • Page 5: Overview: Tools For The Installation

    Installation Instructions Overview: Tools for the installation Battery-powered drill Drilling bit Depending on the mounting Drill set base (Bit AW 10, AW 20) acc. to Mounting base Bit extension Level Measuring tape Pencil Screwdriver Spanners Allen key or ratchet Combination pliers or Side cutter long-nosed pliers Subject to technical modifications –...
  • Page 6: Overview Sintesi

    Installation Instructions Overview SINTESI SINTESI SINTESI Wall installation Ceiling installation SINTESI SINTESI self-supporting single self-supporting double SINTESI FREE SINTESI FREE SINTESI FREE Ceiling installation Lateral installation In-between installation Subject to technical modifications – Date of Issue August/2024...
  • Page 7: Installation Of The Wall/Ceiling Brackets

    Installation Instructions Installation of the wall/ceiling brackets Wall/ceiling brackets In accordance with the illus- tration, hold the brackets to the mounting base and mark the positions for the screw- ing. Depending on the width, cen- tred brackets are enclosed in the delivery.
  • Page 8: Installing The Lateral/Ceiling/Wall Bracket Sintesi Free

    Installation Instructions Installing the lateral/ceiling/wall bracket SINTESI FREE Lateral / ceiling / wall bracket FREE Hold the brackets to the mounting base and adjust them. Provide the boreholes in accordance with the mounting material to be used, and fix the brackets to...
  • Page 9: Installation On Concrete

    Installation Instructions Installation on concrete Installation of the anchor bolts as per approval ETA-05/0069: - Drilled hole preparation ø12 mm Installation of the attachment: - Tightening torque as per ETA- 05/0069 Legend Concrete Installation set 1; anchor bolt FAZ II M12 Bracket Minimum anchoring depth - 70 mm Subject to technical modifications –...
  • Page 10: Installation On Concrete 60-200 Mm Etics

    Installation Instructions Installation on concrete 60-200 mm ETICS Installation of the anchor rod as per ap- proval ETA-02/0024: - Drilled hole preparation ø18 mm - Observe the anchoring depth and the minimum edge distance! - Drilled hole cleaning - Fill drilled hole with mortar FIS V - Slide the anchoring element into the drilled hole - Wait for the curing time...
  • Page 11: Installation On Brickwork

    Installation Instructions Installation on brickwork Installation of the anchor rod as per ap- proval ETA-10/0383: Depending on the type of stone, the in- jection anchor sleeve must be used! - Drilled hole preparation ø12 mm without sleeve ø16 mm with sleeve (16x130) - Drilled hole cleaning - Fill drilled hole (anchor sleeve) with mortar FIS V...
  • Page 12: Installation On Brickwork 60-170 Mm Etics

    Installation Instructions Installation on brickwork 60-170 mm ETICS Installation of the anchor rod as per ap- proval ETA-10/0383: Depending on the type of stone, the in- jection anchor sleeve must be used! - Drilled hole preparation ø18 mm without sleeve ø20 mm with sleeve (20x200) - Drilled hole cleaning - Fill drilled hole (anchor sleeve) with...
  • Page 13: Installation On Wood

    Installation Instructions Installation on wood Installation of the attachment: - Drilled hole preparation ø9 mm - Secure bracket with wood screw and washer Legend Wood Installation set 5; wood screw ø12x120 Bracket Drilled hole depth 125 mm No wind protection class can be given in case of installation on wood due to the variance of the building material.
  • Page 14: Installation On Wood 60-170 Mm Etics

    Installation Instructions Installation on wood 60-170 mm ETICS Installation of the anchor rods: - Drilled hole preparation ø14 mm - Observe the anchoring depth and the minimum edge distance of 100 - Drilled hole cleaning - Lubricate threaded rod - Screw threaded rod into the wood Installation of the Thermax following ap- proval Z-21.8-1837: - Milling open the thermal insulation...
  • Page 15: Installation On Concrete Ceiling Face, Heavy-Duty Bracket

    Installation Instructions Installation on concrete ceiling face, heavy-duty bracket Register constructional situation: - Thickness of the concrete ceiling - Determination of the theoretical posi- tion of the concrete ceiling (consider differences is in the ground) - Determination of the non-bearing layer ETICS (adhesive, insulation, plaster) Legend...
  • Page 16 Installation Instructions Installation on concrete ceiling face, heavy-duty bracket Installation of the anchor rod as per approval ETA-12/0258: - Drilled hole preparation - Observe the anchoring depth and the minimum edge distance! - Drilled hole cleaning - Fill drilled hole with mortar - Slide the anchoring element into the drilled hole - Wait for the curing time...
  • Page 17 Installation Instructions Installation on concrete ceiling face, heavy-duty bracket Inserting the intermediate plate: Fasten with countersunk screws to the heavy-duty bracket. Legend Intermediate plate Countersunk screw M10x25 End plate and spacer plates: The heavy-duty bracket can still be finely adjusted with the aid of two spacer plates of 5 mm each.
  • Page 18 Installation Instructions Installation on concrete ceiling face, heavy-duty bracket Affixing the wall bracket type I: Fasten the end plate and wall bracket type I with hexagon head screws. The end plate must be sealed all around (Fischer Multi adhesive and sealant). Legend Wall bracket type I End plate...
  • Page 19: Installation

    Installation Instructions Installation Rain gutter on columns Screw the rain gutter to the front columns according to the illustration. Place the rain gutter and the columns at the provided positions and pre- vent them from tipping over with the help of ladders. When combining, screw the adjacent bracket of the rain gutter to the slot nuts and...
  • Page 20 Installation Instructions Installation Rain gutter on consoles (SINTESI FREE) Screw the rain gutter to the wall brackets FREE accord- ing to the illustration. The screwing is carried out from below using the slot nuts that are pushed into the rain gut- ter.
  • Page 21 Installation Instructions Installation Rain gutter on consoles (SINTESI FREE with water drainage outlet) Screw the rain gutter to the wall brackets FREE accord- ing to the illustration. The screw connection is made from above through the rain gutter. Legend Rain gutter...
  • Page 22 Installation Instructions Installation Design self-supporting Screw the rear column to the transverse profile according to the illustration. Then screw the end cap (2) onto the transverse profile. Then tighten the strut fastener (4) onto the transverse profile and screw the strut (5) to the strut fastener.
  • Page 23 Installation Instructions Installation Design self-supporting Combination Screw the rear column to the transverse profile according to the illustration. Place the transverse profile and the columns at the provided po- sitions and prevent them from tipping over with the help of ladders or something similar.
  • Page 24 Installation Instructions Installation Wall installation version with transverse profile The wall mounting bracket (1) is fixed to the mounting plate (5) with four M10x20 countersunk screws. The transverse profile is screwed with this wall mounting bracket by means of two countersunk screws (2).
  • Page 25 Installation Instructions Installation Guide rail package Single guide rail Push the guide rail package lat- erally into the wall respective ceiling bracket; adjust it on the outside in such a way that it is flush with the bracket, and clamp it from below with the threaded pins.
  • Page 26 Installation Instructions Installation Guide rail package Double guide rail Push the guide rail package laterally (1) into the wall or ceiling bracket; adjust it in the centre of the the bracket, and clamp it from below with the threaded pins (2). Fixing the rain gutters to the column: Push the rain gutter 2 (7)
  • Page 27 Installation Instructions Installation Mounting direction and screwing Adjust and position the col- umns and guide rails using a spirit level and tape meas- ure. Check the dimensions for width and height as well as the diagonal dimensions. By loosing the lateral locking screws, it is possible to ad- just the height of the bed- plates of the columns.
  • Page 28 Installation Instructions Installation Box unit Before mounting the box unit, the glider (2) must be positioned equally on the right and left side of the guide rail (3). Then the driving square bar (4) must have the same position on the right and left (direction of the splint).
  • Page 29 Installation Instructions Installation Blind package Place the blind package onto the guide rails and screw it to the plastic gliders that are placed in the guide rail. Hook the holding profile for the cover into the box profile and clamp it to the upper side of the box using screws.
  • Page 30 Installation Instructions Installation Telescopic column laterally (optional) Hold the telescopic column beneath the guide rail to the desired position and adjust it. Pull the profiled pipe at the top out of the column, mark the fixing points for the adja- cent bracket on the guide rail and fix with drilling screws.
  • Page 31 Installation Instructions Installation Side closures (optional) Screw the side closures with cylinder head screws to the slot nut, which is placed in the frontal rain gutter. Screw the rear side of the rain gut- ter to the mounting base or, in the case of the self-sup- porting design, to the rear column.
  • Page 32 Cable guiding TERRA SIDE To facilitate the wiring of front- mounted blinds, which are used as lateral closure of the SINTESI, the drive is always provided on the wall side. The cable guiding of the TERRA SIDE beneath the frontal rain gutter is carried out according to the working steps below.
  • Page 33 Installation Instructions Installation Trapezoid kit (optional) The trapezoid kit is the lat- eral upper closure of the per- gola SINTESI. Either a lat- eral Cable routing within the guide rail or a lateral closure is required for the installa- tion.
  • Page 34 Installation Instructions Installation Guide rail covering Place the guide rail cov- erings from the top onto the guide rails and push them laterally outwards. Secure with self-drilling head screws as shown in the illustration. Then place the cover plug into the guide rail cover.
  • Page 35 Installation Instructions Installation Important if designed with rain shelter made of alu- minium: Before the covering profile (1) can be screwed onto the guide rail (2), the hammer- head screws (3) must be pushed into the groove of the covering profile. 5 pieces are supplied per covering profile.
  • Page 36 Installation Instructions Installation Covering caps Mount the covering caps as shown in the illustrations. Legend Screwing to the guide rail end Hinging above the water outlet pipe Bonding with silicone on the wall con- nection bracket Self-supporting: screwing to the end caps of the transverse profile Subject to technical modifications –...
  • Page 37: Installation Of The Rain Shelter Made Of Pvc

    Installation Instructions Installation of the rain shelter made of PVC Rain shelter made of PVC (optional) Hinge the rain shelter profile on the side of the wall into the Z-shaped lugs. Push the locking screws and the Z- shaped lugs towards the wall until the sealing profile is flush with the mounting base.
  • Page 38 Installation Instructions Installation of the rain shelter made of PVC Rain shelter made of PVC (optional) Place the front rain shelter profile on top of the unit and screw it slightly to the slot nuts provided for it. Swivel the distance rods beneath the rain shelter in the rod holders;...
  • Page 39 Installation Instructions Installation of the rain shelter made of PVC Rain shelter made of PVC (optional) Fix the flat aluminium to the left and right of the rain pro- tection canopy using drilling screws. Legend Flat aluminium 25x2 mm Self-drilling head screw 3.9x13 Subject to technical modifications –...
  • Page 40 Installation Instructions Installation of the rain shelter made of PVC Rain shelter made of PVC for combination (optional) Seal the space between the guide rail covers with silicone. (This step only has to be carried out for sys- tem combinations without double guide rail.) Then fasten the flat alu- minium over the entire length of the guide rail using self-screwing drill-...
  • Page 41 Installation Instructions Installation of the rain shelter made of PVC Rain shelter made of PVC Sealing For wall mounting with con- sole plate and transverse profile, the sealing plates shown must be mounted. The sealing plates must be anchored to the wall of the mounting base.
  • Page 42: Installation Of The Rain Shelter Made Of Aluminium

    Installation Instructions Installation of the rain shelter made of aluminium Screw the base frame together. Screw the the side plates (1) to the integrating profile (4) and the rain shelter pro- file (3). For this purpose, use the tapping screws with coun- tersunk head 3.9x19 mm (2).
  • Page 43 Installation Instructions Installation of the rain shelter made of aluminium Fitting the trapezoid steel plates Place the trapezoid steel plates (1) onto the base frame and arrange them ap- propriately. Possibly it is necessary that several grooves overlap. When arrang- ing the trapezoid steel plates, make sure that they are turned correctly.
  • Page 44 Installation Instructions Installation of the rain shelter made of aluminium Riveting the trapezoid steel plates After fitting the trapezoid steel plates (1) into the base frame, it is necessary to rivet them together at the butt joints. For this purpose use the blind rivets ø3x8 mm (2) supplied.
  • Page 45 Installation Instructions Installation of the rain shelter made of aluminium Adjust the base frame on the unit Arrange the hammer-head screws (1) (already pre- mounted, see chapter: As- sembly guide rail cover) and pass them through the re- cesses of the side parts (4). After passing all screws through the recesses, the side part is flush with the ad-...
  • Page 46 Installation Instructions Installation of the rain shelter made of aluminium Fix the base frame on the unit Using the hexagon screws M8x10 (2), fix the mounting bracket (1) made of stainless steel to the L-bracket (3) al- ready fixed to the motor box. (Tighten the screws) Check, if the nuts at the side parts as well as the...
  • Page 47 Installation Instructions Installation of the rain shelter made of aluminium Glue the sealing tape Glue the sealing tape 20 mm x 10 mm (1) along the com- plete length on the inside of the integrating profile. In do- ing so, the self-tapping pan- head screws (2) may be pasted over.
  • Page 48 Installation Instructions Installation of the rain shelter made of aluminium Screw the trapezoid steel plates to the frame Screw the trapezoid steel plates (1) to the base frame, as shown in the illustration. The distances drawn in must be observed. At the front side the trapezoid steel plates must be positioned in such a way that they touch...
  • Page 49 Installation Instructions Installation of the rain shelter made of aluminium Recessing and mounting the wall connection profile (not required for units with ceiling installation) Place the wall connection profile (1) onto the base frame (2) and push it against the wall. Mark the wall thick- ness on the side part and provide a recess with the correct length.
  • Page 50 Installation Instructions Installation of the rain shelter made of aluminium Recessing and mounting the wall connection profile (not required for units with ceiling installation) Then screw the wall connec- tion profile to the base frame. In doing so, observe the maximum distance of 400 mm between the screws and use the supplied screws...
  • Page 51 Installation Instructions Installation of the rain shelter made of aluminium Recessing and mounting the wall connection profile (not required for units with ceiling installation) Important note regarding the screw connections: A screw connection is only possibly within the hatched area of the integration profile (2).
  • Page 52 Installation Instructions Installation of the rain shelter made of aluminium Fix the end caps on the sides Finally rivet the lateral end caps (1) to the brackets us- ing 2 blind rivets 05x08 (2). Differences in alignments between mounting bracket and guide rail may be lev- elled out with glued rubber washers (3) to getting a visu-...
  • Page 53 Installation Instructions Installation of the rain shelter made of aluminium Installation of a rain shelter with unit combinations If a unit combination is in- stalled, separate rain shel- ters are mounted side by side. One rain shelter is fixed on top of each unit element (start element, middle ele- ment, end element).
  • Page 54 Installation Instructions Installation of the rain shelter made of aluminium Installation of a rain shelter with unit combinations Wall connection profile As described above, recess the wall connection profile (1) accordingly and fix it to the base frame. Profession- ally seal the butt joints be- tween the profiles.
  • Page 55: Assembly Top Board Profile Rear Side

    Installation Instructions Assembly top board profile rear side only for self-supporting systems Push the rear top board pro- file (1) over the leg of the wall connection profile (2). Then rivet the top board pro- file (1) in the upper area to the wall connection profile (2) and in the lower area to the transverse profile (3).
  • Page 56: Mounting Cover Profile For Ceiling Brackets

    Installation Instructions Mounting cover profile for ceiling brackets only for ceiling installation The cover profile (2) is fixed to the ceiling brackets (1). Use the filister head screw (4) and washer (3) supplied for screw- ing. Depending on the width, the units are delivered with centre brackets.
  • Page 57: Mounting Rain And Wind Sensor Onyx

    Installation Instructions Mounting rain and wind sensor ONYX Precipitation sensor The 230V power supply (4) for the ONYX control unit (3) can be provided via the 230V junction box (2), or externally if placed remotely from the sys- tem. After connecting the lines, place the ONYX control unit in the retaining bracket (1).
  • Page 58 Installation Instructions Mounting rain and wind sensor ONYX Legend Holding device Junction box 230 V ONYX control unit 230 V supply line for precipitation sensor or ONYX.WEATHER alternative power supply for ONYX.WEATHER Weather sensor ONYX.WEATHER Rain sensor Somfy Ondeis 230 V Control lines for precipitation sensor Ondeis Subject to technical modifications –...
  • Page 59: Notes On Toothed Belt Connection/Tension

    Installation Instructions Notes on toothed belt connection/tension The filister head screw (1) is already marked red at the factory. This screw may only be loosened during repair work (toothed belt replacement, re- placement of idler pulleys). Attention: The toothed belt is tensioned! Before the filister head screw (1) can be loosened or unscrewed, the toothed belt must be slackened by loosening...
  • Page 60: Electric Plug-In Connections

    Installation Instructions Electric plug-in connections Legend Junction box (230 V) Version with Somfy io: 230 V cables with Hirschmann plug connection STAS 3/STAK 3 Version with ONYX: 230 V cables with Hirschmann plug connection STAS 3/STAK 3 ONYX.CONNECTOR LED control unit 24 V cables with Hirschmann plug connection STAS 2/STAK 2 Subject to technical modifications –...
  • Page 61 Installation Instructions Electric plug-in connections Motors for SINTESI cover and TERRA SIDE All 230 V cables via Hirschmann plug connection STAS 3/STAK 3. There is no special wiring diagram for terminal connections in the area of the junction box. All connections are provided with 230 V.
  • Page 62: Adjusting The Motor

    Radio motors: With these drives the adjustment of the end position is done via the corre- sponding hand-held radio transmitter. End position adjustment for SINTESI cover Inner end position (cover retracted) Must be programmed as a fixed end po- sition.
  • Page 63: Wiring Diagram For The Motors

    Installation Instructions Wiring diagram for the motors SINTESI cover and TERRA SIDE with ONYX.CONNECTOR Legend Hirschmann Junction box STAK 3 ONYX.CONNECTOR Motor Hirschmann STAS 3 for power STAS 3 supply 1 Neutral conductor 2 Phase L 3 Connection 3 not...
  • Page 64 Installation Instructions Wiring diagram for the motors SINTESI cover and TERRA SIDE with Somfy io Legend Junction box Hirschmann plug connection Somfy io motor Hirschmann STAK 3 Hirschmann STAS 3 For more details concerning the electrical connections, powers, operating instructions and programming, please refer to the enclosed documents of the manufacturer or the HELLA installation instructions.
  • Page 65: Wiring Diagram For The Led Lighting

    Installation Instructions Wiring diagram for the LED lighting ONYX / Somfy io Legend Junction box Hirschmann Hirschmann plug connection STAK 3 Control unit LED ONYX / Somfy io Hirschmann plug connection Connection of LED strips Hirschmann STAS 3 230 V AC 24 V DC Hirschmann STAK 2...
  • Page 66: Operation And Configuration Pergola Plus With Onyx

    Operation and configuration Pergola PLUS with ONYX General Before configuring Pergola PLUS with ONYX, download HELLA’s free app ONYX from the App store/Google Play to your smart phone. Before you can use Pergola PLUS together with ONYX.CENTER or ONYX.CLICK, it must be added in the ONYX app. You will find everything about the configuration in the instructions for ONYX.CENTER /...
  • Page 67 Installation Instructions Operation and configuration Pergola PLUS with ONYX Canopy drive The pergola can be extended or retracted by activating a hand-held radio transmitter or an automatic device. Pergola PLUS is displayed as ONYX.CONNECTOR when it is taught in the ONYX App.
  • Page 68 Installation Instructions Operation and configuration Pergola PLUS with ONYX TERRA SIDE drive Pergola PLUS TERRA SIDE is displayed as ONYX.CONNECTOR when it is taught in the ONYX App. Stand alone configuration with ONYX.CLICK To configure Pergola PLUS TERRA SIDE, you first have to connect to the ONYX.CLICK hand-held radio transmitter via the ONYX app.
  • Page 69 Installation Instructions Operation and configuration Pergola PLUS with ONYX Lighting Stand alone configuration with ONYX.CLICK To configure the Pergola PLUS lighting, you first have to connect to the ONYX.CLICK hand-held radio transmitter via the ONYX app. The lighting is configured and added under “Configure devices” and “+”. Smart home configuration with ONYX.CENTER To configure the Pergola PLUS lighting, you simply have to connect to ONYX.CENTER in the ONYX app.
  • Page 70 Installation Instructions Operation and configuration Pergola PLUS with ONYX Frost sensor (included with Pergola PLUS) A temperature threshold can be set via the ONYX app, so that the product is protected. The canopy and the TERRA SIDE shades retract when the value falls be- low the set threshold and remain blocked.
  • Page 71 Installation Instructions Operation and configuration Pergola PLUS with ONYX Wind sensor (included with Pergola PLUS) A wind threshold can be set via the ONYX app to protect the product in strong winds. The canopy and the TERRA SIDE shades retract when the value falls be- low the set threshold and remain blocked.
  • Page 72 Precipitation sensor for rain/snow detection If the suitable sensor technology is used, the Pergola PLUS can be addi- tionally provided with a rain and snow sensor. HELLA article number ONYX control unit wit rain sensor 05200114 Rain: When rain is detected, the canopy and the TERRA SIDE shades move to a predefined position (open or closed).
  • Page 73 Installation Instructions Operation and configuration Pergola PLUS with ONYX General When using several different sensors, the following prioritisation applies in the ONYX.HOME Smart Home System. Higher prioritised functions override functions with a lower prioritisation. Snow (precipitation sensor) Frost (frost sensor) Wind (wind sensor) Rain (precipitation sensor) Sun (sun sensor)
  • Page 74: Operation And Configuration Pergola With Somfy Io

    Installation Instructions Operation and configuration Pergola with Somfy io The pergola can be extended or retracted by activating a hand-held radio transmitter or an automatic device. Please refer to the enclosed instructions of the manufacturer for operating possibilities via control devices. Hand-held radio transmitter with scroll wheel Setting the scroll wheel function with hand-held radio transmitter “Somfy Situo 5 Variation A/M io”:...
  • Page 75: Sensors Somfy Io

    Sun sensor Connecting a sun sensor to the SINTESI as well as to the TERRA SIDE is possible, too. Sensor required: Somfy SunisWireFree II - Art.-No. 05200104 (battery-powered). The sun sensor is only possible with the control components Somfy TaHoma Premium Box io or Connexoon io.
  • Page 76: Commissioning/Functional Check

    Installation Instructions Commissioning/functional check Extend and retract the unit in and out completely. When extending the unit for the first time, make sure no one is in the operating radius or standing be- low the unit. Make sure that during the later operation the units can be extended freely and without blockings.
  • Page 77: Removal

    Installation Instructions Removal Switch the unit dead and take safety precautions against unintentional switching on. The removal is carried out in reverse order to the installation. Subject to technical modifications – Date of Issue August/2024...
  • Page 78 Installation Instructions For questions, wishes and ideas: HELLA Infoline +43/(0)4846/6555-0 HELLA Sonnen- und Wetterschutztechnik GmbH A-9913 Abfaltersbach, No. 125 Phone: +43/(0)4846/6555-0 Fax: +43/(0)4846/6555-134 e-mail: office@hella.info Internet: http://www.hella.info...
  • Page 79: Schematic Wiring Diagram

    Drive for TERRA SIDE (230V) ONYX.CONNECTOR with Hirschmann plug connection STAS 3/STAK 3 for TERRA SIDE drive (230V) ONYX.CONNECTOR with Hirschmann plug connection STAS 3/STAK 3 for SINTESI drive (230V) Cable connector IP68 for TERRA SIDE drive (230V), 4-pole Adapter plug for the control ONYX.CONNECTOR...
  • Page 80 Installation Instructions and Instructions for Use Schematic wiring diagram SINTESI self-supporting with ONYX Front part identical to wall/ceiling installation; supply line via rear column Legend 24V LED lighting 2-pole (+/-) 230V Voltage supply 3-pole (L/N/PE) 230V Voltage supply 4-pole (L/L/N/PE)
  • Page 81 Drive for TERRA SIDE (230V) Hirschmann plug connection STAS 3/STAK 3 for TERRA SIDE drive (230V) Hirschmann plug connection STAS 3/STAK 3 for SINTESI drive (230V) Cable connector IP68 for TERRA SIDE drive (230V), 3-pole Subject to technical modifications – Date of Issue September/2022...
  • Page 82 Installation Instructions and Instructions for Use Schematic wiring diagram SINTESI self-supporting with Somfy io Front part identical to wall/ceiling installation; supply line via rear column Legend 24V LED lighting 2-pole (+/-) 230V Voltage supply 3-pole (L/N/PE) Junction box (230V) Main connector (230V)
  • Page 83: Detailed Wiring Diagram

    Installation Instructions and Instructions for Use Detailed wiring diagram SINTESI with ONYX Legend Mains connection LED in cover profiles Potential equalisation Flat plug Additional module SINTESI 2 Quick connector On the left side At the front Brown On the right side Blue Cable connector...
  • Page 84 Installation Instructions and Instructions for Use Detailed wiring diagram SINTESI with Somfy io Legend Mains connection LED in cover profiles Potential equalisation Flat plug Additional module SINTESI 2 Quick connector On the left side At the front Brown On the right side...

Table of Contents