Summary of Contents for Sun Microsystems Sun StorEdge 2 Gb FC
Page 1
Sun StorEdge 2 Gb FC ™ Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 819-1670-12 January 2007, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
Page 2
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la limitation, ces droits de propriété...
Contents Preface v Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide 1 System Requirements 2 Installing the HBA 2 ▼ To Verify the Packaging Contents 2 ▼ To Install the HBA Hardware 3 Installing the HBA Driver 6 Sun Solaris 10 Operating System for x86 Platforms 7 ▼...
Page 4
To Create a Boot Disk 13 Declaration of Conformity, Regulatory Compliance, and Safety Statements 15 Declaration of Conformity 17 Regulatory Compliance Statements 19 Safety Agency Compliance Statements 23 Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide • January 2007...
Preface This guide describes how to install the Sun StorEdge™ 2 Gb FC Entry-Level PCI-X Single Channel host bus adapter (HBA), and how to update the driver. How This Book Is Organized The single chapter describes how to install the HBA and update the driver. Appendix A provides the safety, regulatory, and compliance information for the product.
* The settings on your browser might differ from these settings. Related Documentation Application Title Part Number Latest information Sun StorEdge 2 Gb FC Entry Level PCI-X Single 819-1671 Channel Host Bus Adapter Release Notes Locating documents Accessing Documentation 819-1209...
Accessing Sun Documentation You can view, print, or purchase a broad selection of Sun documentation, including localized versions, at: http://www.sun.com/documentation Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources.
Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions. You can submit your comments by going to: http://www.sun.com/hwdocs/feedback Please include the title and part number of your document with your feedback: Sun StorEdge™ 2 Gb FC Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide, part number 819-1670-12 viii Sun StorEdge™...
This guide describes how to install and configure your new Sun StorEdge™ 2 Gb FC Entry-Level PCI-X Single Channel host bus adapter (HBA) in three simple steps. This guide also describes how to update the Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA drivers.
(see FIGURE 1 Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA ■ Extra PCI bracket ■ Accessing Documentation, 819-1209-xx ■ Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
PCI slot (32 or 64 bit). If necessary, consult your computer system manual for instructions to remove the computer cover. Note – If you are installing the Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA in a Windows system, see Step 4 “To Download and Install the...
Page 12
Position the new bracket over the transceiver housings. d. Align the screw holes of the HBA and the bracket, then insert and tighten the screws to a torque of 3.6 in-lbs. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Page 13
6. Refasten the retaining bracket of the HBA by using the existing screw or lever. 7. Close the computer cover. 8. Plug in the power cable and turn on the computer. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide...
“Red Hat Enterprise Linux 3 and SuSE Linux Enterprise Server 8 Systems” on ■ page 9 “Windows 2000 or Windows Server 2003” on page 11 ■ Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
7. Access the directory and unzip the patch. 8. Use the patchadd command to install the patch. Note – Refer to the product Release Notes, 819-1671-xx, for the latest information on software requirements. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide...
HBA is available beginning with SunVTS 6.0 software. Install SunVTS 6.0 software per instructions from your Solaris 10 distribution. Patch 119275 is required for the SunVTS 6.0 to support the Sun StorEdge 2 Gb FC Entry- Level PCI-X Single Channel HBA.
5. Click the Readme and locate the install steps for using the .tgz source package. 6. Follow the instructions and download the driver source by clicking the associated Download. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel Host Bus Adapter Installation Guide...
5. Click the Readme for the download and install instructions. To Create a Boot Disk ▼ 1. Connect the disk to the Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA. 2. Go to the QLogic download site for Sun Microsystems: www.qlogic.com/support/oem_detail_all.asp?oemid=124...
Make sure the operating system is installed, and that your system is configured ■ with the latest Service Pack and Windows Update. The driver is only installed once, even if you have multiple Sun StorEdge 2 Gb FC ■ Entry-Level PCI-X Single Channel HBAs in the system.
Be sure the HBA you selected for diagnostics is connected to an active fiber link (storage or switch fabric) or to a loop back cable. 8. Click Next to return to the SANsurfer HBA Install Wizard window (main). Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
4. Click Download in the right column. To Create a Boot Disk ▼ 1. Connect the disk to the Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA. 2. Go to the QLogic download site for Sun Microsystems: www.qlogic.com/support/oem_detail_all.asp?oemid=124 3.
Page 22
Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
A P P E N D I X Declaration of Conformity, Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorEdge 2 Gb FC Entry Level PCI-X Single Channel Host Bus Adapter: “Declaration of Conformity” on page 17 ■...
Page 24
Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
DATE Donald Cameron DATE Worldwide Compliance Office Quality Manager/Quality Systems Sun Microsystems, Inc. Sun Microsystems Scotland, Limited 4150 Network Circle, MPK15-102 Blackness Road, Phase I, Main Bldg. Santa Clara, CA 95054, U.S.A. Springfield, EH49 7LR Tel: 650-786-3255 Scotland, United Kingdom...
Page 26
Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
Page 28
ICES-003 Class B Notice - Avis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. T33012 D33012 CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A” on the product’s compliance label.
Page 30
Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Do not make mechanical or electrical modifications to the the equipment’s electrical rating label. equipment. Sun Microsystems is not responsible for Never push objects of any kind through openings in ■ regulatory compliance of a modified Sun product.
Do not connect the power cord when the power supply has been removed from the system chassis. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Rack System Warning CD and DVD Devices The following warnings apply to Racks and Rack Mounted The following caution applies to CD, DVD, and other systems. optical devices. Caution – For safety, equipment should Caution – Use of controls, adjustments, or the always be loaded from the bottom up.
Page 34
Conformité SELV cordons d'alimentation. Le niveau de sécurité des connexions E/S est conforme aux normes SELV. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Page 35
Mise en garde relative aux batteries Attention – Afin d'éviter que le rack ne penche pendant l'installation du matériel, tirez Attention – Les batteries risquent d’exploser la barre anti-basculement du rack. en cas de manipulation maladroite ou de remplacement incorrect. Pour les systèmes dont les batteries sont remplaçables, effectuez Attention –...
Page 36
70 dB(A). Achtung – Gefährliche Spannungen. Befolgen Sie die Anweisungen, um Stromschläge und Verletzungen zu vermeiden. SELV-Konformität Der Sicherheitsstatus der E/A-Verbindungen entspricht den SELV-Anforderungen. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Anschluss des Netzkabels Warnung bezüglich Batterien Achtung – Sun-Geräte sind für Achtung – Bei unsachgemäßer Handhabung Stromversorgungssysteme mit einem oder nicht fachgerechtem Austausch der geerdeten neutralen Leiter (geerdeter Batterien besteht Explosionsgefahr. Verwen- Rückleiter bei gleichstrombetriebenen den Sie bei Systemen mit austauschbaren Geräten) ausgelegt.
Page 38
Geräte: personales, siga las instrucciones. Achtung – Die hier nicht aufgeführte Verwendung von Steuerelementen, Anpassungen oder Ausführung von Vorgängen kann eine gefährliche Strahlenbelastung verursachen. Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Page 39
Precaución – No todos los cables de alimentación tienen la misma clasificación No realice modificaciones de tipo mecánico ni eléctrico en el equipo. Sun Microsystems no se hace responsable del eléctrica. Los alargadores de uso doméstico no cuentan con protección frente a sobrecargas y cumplimiento de normativas en caso de que un producto no están diseñados para su utilización con...
Page 40
Class 1 Laser Product cubierta. De lo contrario, puede sufrir lesiones Luokan 1 Laserlaite personales y ocasionar daños en el sistema. Klasse 1 Laser Apparat Laser Klasse 1 Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Page 41
Dispositivos de CD y DVD La siguiente medida se aplica a los dispositivos de CD y DVD, así como a otros dispositivos ópticos: Precaución – La utilización de controles, ajustes o procedimientos distintos a los aquí especificados puede dar lugar a niveles de radiación peligrosos.
Page 42
Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
Need help?
Do you have a question about the Sun StorEdge 2 Gb FC and is the answer not in the manual?
Questions and answers