UV2400U6000 AirBRIGHT® 6
Ultraviolet Air Purifier with Carbon
Installation Instructions
Before Installing this Product
Read these instructions carefully; failure to follow them could damage
the product and cause a hazardous situation.
Installer must be a trained, experienced service technician.
WARNING: UV Light Hazard.
Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at
lamps while illuminated.
• To prevent exposure to ultraviolet light, disconnect power to the ultraviolet air treatment system before servicing any part
of the heating/air conditioning system.
• View illumination only through lamp handle or sight glass.
• Do not attempt to bypass duct mount switch.
• Do not attempt to open housing; unit is sealed to prevent ultraviolet light exposure.
CAUTION: Personal Injury Hazard. HVAC power supply can cause electrical shock.
Disconnect HVAC power supply before installing, cleaning or replacing ultraviolet lamp(s).
CAUTION: Breakable Glass Hazard. Can cause personal injury.
• Be careful when inserting lamp(s) into lamp base.
• Wear protective gloves when handling lamp(s).
CAUTION: Personal Injury Hazard. Power supply can cause electrical shock.
• Disconnect power supply before cleaning or replacing ultraviolet lamp(s).
• Do not open base unit or lamp handle; there are no user-serviceable components inside.
CAUTION: UV Lamp Burn Hazard. Harmful to bare skin. Can cause severe burns.
• Disconnect power 15 minutes before removing ultraviolet lamp(s).
Included Inside Box
• Carbon air purifier system
• 24 VAC power supply
• Core
• UV-C lamp
• 40VA transformer
• Mounting plate
• Mounting hardware
• Installation instructions
• Sight glass
• UV warning stickers
M39524

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirBRIGHT 6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Honeywell Home AirBRIGHT 6

  • Page 1 UV2400U6000 AirBRIGHT® 6 Ultraviolet Air Purifier with Carbon Installation Instructions Before Installing this Product Read these instructions carefully; failure to follow them could damage the product and cause a hazardous situation. M39524 Installer must be a trained, experienced service technician. WARNING: UV Light Hazard.
  • Page 2: Specifications

    Ozone UL 2998 validated no ozone. UV Installation Notes We recommend the AirBRIGHT 6 UV Air Purifier be installed on the supply side duct 3-5 inches above • the A-coil. The germicidal UV light should be positioned to shine on the surfaces that are prone to mold growth like •...
  • Page 3: Metal Ductwork Installation

    Metal Ductwork Installation Locate a suitable area of the duct for • installation. Minimum 7” area. If needed, cut away insulation to expose metal • duct. Mark location for 5” opening using the included • mounting plate as a template. Cut opening for the device.
  • Page 4: Mercury Notice

    Golden Valley, MN 55422 www.resideo.com 33-00673EFS-01 SA Rev. 05-24 © 2024 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. 33-00673EFS-01 This product is manufactured by Resideo Technologies, Inc. and its affiliates.
  • Page 5: Avant D'installer Ce Produit

    UV2400U6000 AirBRIGHT® 6 Purificateur d'air ultraviolet avec du charbon Guide d'installation Avant d'installer ce produit Lisez attentivement ces instructions ; si vous ne les suivez pas, vous risquez le produit et aussi de provoquer une situation dangereuse. M39524 L'installateur doit être un technicien de service formé et expérimenté. AVERTISSEMENT : Risque lié...
  • Page 6: Spécifications

    Ozone Validée par UL 2998, sans ozone. Notes sur l'installation des UV Nous recommandons que le purificateur d'air AirBRIGHT 6 UV soit installé sur le conduit d'alimentation • 3-5" pouces au-dessus de la bobine d'évaporation. La lumière UV germicide doit être positionnée de manière à éclairer les surfaces qui sont sujettes à la •...
  • Page 7 Installation des conduits métalliques Localisez une zone appropriée pour linstallation du • conduit. Surface minimale de 8" pouces. Si nécessaire, coupez l'isolant pour exposer le • conduit métallique. Marquez l'emplacement de l'ouverture de 5" en • utilisant la plaque de montage fournie comme patron.
  • Page 8: Pièces De Rechange

    Valley, MN 55422 www.resideo.com 33-00673EFS-01 SA Rév. 05-24 2024 Resideo Technologies, Inc. Tous les droits réservés. La marque Honeywell Home est utilisée sous licence par Honeywell International, Inc. 33-00673EFS-01 Ce produit est fabriqué par Resideo Technologies, Inc. et ses filiales.
  • Page 9: Antes De Instalar Este Producto

    UV2400U6000 AirBRIGHT® 6 Purificador de aire ultravioleta con carbón Instrucciones de instalación Antes de instalar este producto Lea atentamente estas instrucciones; el incumplimiento de las mismas podría dañar el producto y provocar una situación de peligro. M39524 El instalador debe ser un técnico de servicio capacitado y experimentado. ADVERTENCIA: Peligro por luz ultravioleta.
  • Page 10: Especificaciones

    UL 2998 validado sin ozono. Notas sobre la instalación de UV Recomendamos que el purificador de aire UV AirBRIGHT 6 se instale en el conducto del lado de • suministro a una distancia de 3 a 5 pulgadas por encima del serpentin en forma de A.
  • Page 11 Instalación de conductos metálicos Localice una zona adecuada del conducto para la • instalación. Área mínima de 7”. Si es necesario, corte el aislamiento para exponer el • conducto metálico. Marque la ubicación para la abertura de 5" utilizando la •...
  • Page 12: Piezas De Repuesto

    Valley, MN 55422 www.resideo.com 33-00673EFS-01 SA Rev. 05-24 2024 Resideo Technologies, Inc. Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc. 33-00673EFS-01 Este producto está fabricado por Resideo Technologies, Inc. y sus filiales.