ENGLISH Read these instructions for use carefully and keep them for later use. Make them accessible to other users and note the information they contain. Table of contents 1. Included in delivery ............3 7. Usage ................10 2. Signs and symbols ............4 8.
2. SIGNS AND SYMBOLS Battery disposal Do not dispose of batteries containing The following symbols are used on the device, in these in- harmful substances with household waste structions for use, on the packaging and on the type plate Marking to identify the packaging material. for the device: A = material abbreviation, B = material Warning...
measurements and can also output average values of previ- Medical device ous measurements. CE labelling 4. WARNINGS AND SAFETY NOTES This product satisfies the requirements of the applicable European and national directives. Contraindications Authorised representative in the European • Do not use the blood pressure monitor on newborns, chil- Community dren or pets.
• Do not perform measurements more frequently than nec- General warnings essary. Due to the restriction of blood flow, some bruising • The measurements taken by you are for your information may occur. only – they are no substitute for a medical examination! •...
• We recommend that the batteries be removed if the de- such as error messages or the failure of the display/de- vice will not be used for a prolonged period of time. vice. • Avoid using this device directly next to other devices or Measures for handling batteries stacked on top of other devices, as this could lead to •...
Information on the display: If the battery change symbol is flashing and appears, no further measurements are possible and you must The corresponding drawings are shown on page 3. replace all batteries. Once the batteries have been removed Time and date Calculated pulse rate from the device, the date and time must be set again.
Hour format The minutes flash on the display. • Select the desired minute using the M1 or M2 The hour format flashes on the display. memory button and confirm with the START/ • Select the desired hour format using the STOP button M1 or M2 memory button and confirm with the START/STOP button...
7. USAGE check the fit of the cu and, in doing so, ensure that their wrist circumference is within the range printed on the cu . General information about blood pressure • Uncover your wrist. Ensure that the circulation of the wrist is not hindered by tight clothing or similar.
Performing the blood pressure measurement Display Interpretation Position indicator You have not yet reached the recom- Measurement is coloured red mended position of the measuring Press the START/STOP button to start the blood pressure device at heart level – your wrist is monitor.
Page 12
1 minute. In this case too, the In the “beurer HealthManager Pro” app, add the value is stored in the selected or most recently used user BC 87 under Settings / Devices and follow the memory. instructions.
Page 13
Reliable assess- to your smartphone. ment is only possible when you perform the measure- • Ensure that the “beurer HealthManager Pro” app on your ment regularly under comparable conditions. smartphone is always activated and launched when you start the data transfer on the device.
to give you your personal target values for controlled blood Measured blood Colour of pressure – in particular if you receive medicinal therapy. pressure value range Classification the risk Systole Diastole Irregular heartbeat indicator (in mmHg) (in mmHg) This device can identify any irregular heartbeat disturbances High blood pressure as part of the analysis of your recorded pulse signal during ≥...
Page 15
This enables it to indicate whether the blood pressure was However, certain patients su ering from irregular heartbeat or taken when the user’s circulatory system was su ciently at chronic mental conditions may remain haemodynamically un- rest. stable even in the long-term, something which persists even after repeated periods of rest.
Average values Deleting measured values Press the M1 memory button. Then confirm • In order to delete a user memory, first select the user your selection by pressing the START/STOP memory to be deleted by pressing the M1 or M2 memory button button when the device is switched o and confirming •...
9. REMEDY Error Possible cause Solution mes- Error Possible cause Solution sage mes- The inflation pres- Please take another sage sure is higher than measurement to check Unable to record a Please wait one 300 mmHg. whether the cu can be pulse.
10. DISPOSAL 11. TECHNICAL SPECIFICATIONS Model no. BC 87 Repairing and disposing of the device Measurement method Oscillometric, non-invasive blood • Do not repair or adjust the device yourself. Proper opera- pressure measurement on the wrist tion can no longer be guaranteed in this case.
Conformity for this product can be found at: Compatible with Bluetooth ≥ 4.0 smartphones/tablets https://www.beurer.com/conformity The serial number is located on the device or in the battery 12. WARRANTY/SERVICE compartment. Further information on the warranty and warranty conditions Technical information is subject to change without notification...
flicker emissions antennas) should be used no closer than 30 cm IEC 61000-3-3 (12 inches) to any part of the equipment BC 87, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
Page 21
Table 2 Conduced RF Not applicable Not applicable IEC61000-4-6 Guidance and manufacturer’s declaration – electro- magnetic Immunity Radiated RF 10 V/m 10 V/m IEC61000-4-3 80 MHz – 2,7 GHz 80 MHz – 2,7 GHz Immunity test IEC 60601-1-2 Compliance 80 % AM at 1 kHz 80 % AM at 1 kHz Test level level...
Page 22
Table 3 Guidance and manufacturer’s declaration - electromagnetic Immunity Radiated RF Test Band Service Modulation Modulation Distance IMMUNITY IEC61000-4-3 Frequency (MHz) TEST LEVEL (Test speci- (MHz) (V/m) fications for 380-390 TETRA Pulse modula- ENCLOSURE tion b) 18Hz PORT IMMUNITY 430-470 GMRS 460, FM c) 5kHz to RF wireless...
Page 24
® The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Beurer GmbH is under license. Other trademarks and trade names are those of their respective owners. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S.
Need help?
Do you have a question about the BC 87 and is the answer not in the manual?
Questions and answers