HP 5500-24G-4SFP HI Manual
HP 5500-24G-4SFP HI Manual

HP 5500-24G-4SFP HI Manual

Hide thumbs Also See for 5500-24G-4SFP HI:
Table of Contents

Advertisement

Quick Links

Contents
Product overview ······························································································································································ 1
5500-24G-4SFP HI (2 slots) panel views ······················································································································· 2
5500-48G-4SFP HI (2 slots) panel views ······················································································································· 3
5500-24G-SFP HI (2 slots)/5500-24G-SFP HI TAA (2 slots) panel views ·································································· 4
5500-24G-PoE+-4SFP HI (2 slots)/ 5500-24G-PoE+-4SFP HI TAA (2 slots) panel views ········································ 5
5500-48G-PoE+-4SFP HI (2 slots)/ 5500-48G-PoE+-4SFP HI TAA (2 slots) panel views ········································ 6
Preparing for installation ················································································································································· 7
Safety recommendations ·················································································································································· 7
Examining the installation site·········································································································································· 7
Temperature/humidity ············································································································································· 7
Cleanness ·································································································································································· 8
EMI ············································································································································································· 8
Laser safety ································································································································································ 8
Installing the switch ························································································································································ 10
Installing the switch in a 19-inch rack ·························································································································· 11
Rack-mounting restrictions and guidelines ·········································································································· 11
Mounting accessory kit ········································································································································· 11
Rack-mounting by using front mounting brackets ······························································································· 13
Rack-mounting by using front and rear mounting brackets··············································································· 14
Mounting the switch on a workbench ·························································································································· 16
Grounding the switch ···················································································································································· 17
Grounding the switch with a grounding strip ····································································································· 17
Grounding the switch with a grounding conductor buried in the earth ground ············································· 19
Grounding the switch by using the AC power cord ·························································································· 19
Installing/removing a power supply ···························································································································· 20
Installing a PSR150 series power supply ············································································································ 20
Removing a PSR150 series power supply ·········································································································· 22
Installing a PSR720-56A/PSR1110-56A power supply ··················································································· 22
Removing a PSR720-56A/PSR1110-56A power supply ·················································································· 23
Connecting the power cord ·········································································································································· 25
Connecting the PSR150-A/PSR150-A1 ·············································································································· 26
Connecting the PSR150-D/PSR150-D1 ·············································································································· 26
Connecting the PSR720-56A/PSR1110-56A ···································································································· 27
Installing/removing an interface card ························································································································· 28
Installing an interface card ··································································································································· 28
Removing an interface card ································································································································· 30
Installing/removing a CX4/SFP+ cable·············································································································· 30
Verifying the installation ················································································································································ 31
Accessing the switch for the first time ·························································································································· 32
Setting up the configuration environment ···················································································································· 32
Connecting the console cable······································································································································· 32
Console cable ························································································································································ 32
Connection procedure ·········································································································································· 32
Setting terminal parameters ·········································································································································· 33
Powering on the switch·················································································································································· 36
Setting up an IRF fabric ················································································································································· 37
IRF fabric setup flowchart ·············································································································································· 37
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5500-24G-4SFP HI and is the answer not in the manual?

Questions and answers

Summary of Contents for HP 5500-24G-4SFP HI

  • Page 1: Table Of Contents

    Contents Product overview ······························································································································································ 1 5500-24G-4SFP HI (2 slots) panel views ······················································································································· 2 5500-48G-4SFP HI (2 slots) panel views ······················································································································· 3 5500-24G-SFP HI (2 slots)/5500-24G-SFP HI TAA (2 slots) panel views ·································································· 4 5500-24G-PoE+-4SFP HI (2 slots)/ 5500-24G-PoE+-4SFP HI TAA (2 slots) panel views ········································ 5 5500-48G-PoE+-4SFP HI (2 slots)/ 5500-48G-PoE+-4SFP HI TAA (2 slots) panel views ········································...
  • Page 2 Interface card status LED ······································································································································· 62 Port LED on the interface card ······························································································································ 62 I/O status LED on the power supply ··················································································································· 63 Support and other resources ········································································································································· 64 Contacting HP ································································································································································ 64 Subscription service ·············································································································································· 64 Related information ························································································································································ 64 Documents ······························································································································································ 64 Websites ·································································································································································...
  • Page 3 Index ················································································································································································ 67...
  • Page 4: Product Overview

    IMPORTANT: For regulatory identification purposes, the HP 5500 HI switches are assigned regulatory model numbers (RMN). These regulatory numbers should not be confused with the marketing names HP 5500, or product numbers. This chapter describes the chassis panel views of the 5500 HI switches.
  • Page 5: 5500-24G-4Sfp Hi (2 Slots) Panel Views

    The 5500-24G-4SFP HI (2 slots) switch comes with two expansion interface card slots covered by filler panels. The 5500-24G-4SFP HI (2 slots) switch comes with power supply slot 1 covered by a filler panel and power supply slot 2 empty. In this figure, a PSR150-A (JD362A) power supply is installed in power...
  • Page 6: 5500-48G-4Sfp Hi (2 Slots) Panel Views

    5500-48G-4SFP HI (2 slots) panel views Figure 3 5500-48G-4SFP HI (2 slots) front panel 17 16 (1) 10/100/1000 Base-T auto-sensing Ethernet port (2) 10/100/1000 Base-T Ethernet port LED (3) SFP port LED (4) 100/1000Base-X SFP port (5) Management Ethernet port (Management) (6) Console port (7) Seven-segment LED (Unit) (8) Port LED mode switching button...
  • Page 7: 5500-24G-Sfp Hi (2 Slots)/5500-24G-Sfp Hi Taa (2 Slots) Panel Views

    5500-24G-SFP HI (2 slots)/5500-24G-SFP HI TAA (2 slots) panel views Figure 5 5500-24G-SFP HI (2 slots)/5500-24G-SFP HI TAA (2 slots) front panel (1) 100/1000 Base-X SFP port (2) SFP port LED (3) 10/100/1000 Base-T Ethernet port LED (4) SFP+ port LED (5) Management Ethernet port LED (ACT/LINK) (6) Seven-segment LED (Unit) (7) Port mode LED (Mode)
  • Page 8: 5500-24G-Poe+-4Sfp Hi (2 Slots)/ 5500-24G-Poe+-4Sfp Hi Taa (2 Slots) Panel Views

    5500-24G-PoE+-4SFP HI (2 slots)/ 5500-24G-PoE+-4SFP HI TAA (2 slots) panel views Figure 7 5500-24G-PoE+-4SFP HI (2 slots)/5500-24G-PoE+-4SFP HI TAA (2 slots) front panel (1) 10/100/1000 Base-T auto-sensing Ethernet port (2) 10/100/1000 Base-T Ethernet port LED (3) SFP port LED (4) SFP+ port LED (5) Management Ethernet port LED (ACT/LINK) (6) Seven-segment LED (Unit) (7) Port mode LED (Mode)
  • Page 9: 5500-48G-Poe+-4Sfp Hi (2 Slots)/ 5500-48G-Poe+-4Sfp Hi Taa (2 Slots) Panel Views

    5500-48G-PoE+-4SFP HI (2 slots)/ 5500-48G-PoE+-4SFP HI TAA (2 slots) panel views Figure 9 5500-48G-PoE+-4SFP HI (2 slots)/5500-48G-PoE+-4SFP HI TAA (2 slots) front panel 17 16 (1) 10/100/1000 Base-T auto-sensing Ethernet port (2) 10/100/1000 Base-T Ethernet port LED (3) SFP port LED (4) 100/1000 Base-X SFP port (5) Management Ethernet port (Management) (6) Console port...
  • Page 10: Preparing For Installation

    Preparing for installation Safety recommendations To avoid any equipment damage or bodily injury caused by improper use, read the following safety recommendations before installation. Note that the recommendations do not cover every possible hazardous condition. Before cleaning the switch, unplug all power cords from the switch. Do not clean the switch with wet cloth or liquid.
  • Page 11: Cleanness

    Lasting low relative humidity can cause washer contraction and ESD and bring problems including loose captive screws and circuit failure. High temperature can accelerate the aging of insulation materials and significantly lower the reliability and lifespan of the switch. For the temperature and humidity requirements, see "Appendix A Technical specifications."...
  • Page 12 WARNING! Do not stare into any fiber port when the switch has power. The laser light emitted from the optical fiber may hurt your eyes.
  • Page 13: Installing The Switch

    CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact HP for permission. Otherwise, HP shall not be liable for any consequence. Figure 11 Hardware installation flow...
  • Page 14: Installing The Switch In A 19-Inch Rack

    Table 4 Rack-mounting restrictions and guidelines Mounting method Restrictions and guidelines Only applicable to the 5500-24G-4SFP HI (2 slots), 5500-48G-4SFP HI (2 slots), 5500-24G-SFP HI (2 slots), and 5500-24G-SFP HI TAA (2 slots) switches. Install the front mounting brackets at the port-side or power-side mounting Rack-mounting by using front position as needed.
  • Page 15 5500-24G-PoE+-4SFP HI (2 slots) 5500-24G-4SFP HI (2 slots) 5500-24G-PoE+-4SFP HI TAA (2 5500-48G-4SFP HI (2 slots) slots) Accessories 5500-24G-SFP HI (2 slots) 5500-48G-PoE+-4SFP HI (2 slots) 5500-24G-SFP HI TAA (2 5500-48G-PoE+-4SFP HI TAA (2 slots) slots) One pair of 1U front mounting...
  • Page 16: Rack-Mounting By Using Front Mounting Brackets

    Rack-mounting by using front mounting brackets This mounting method is applicable to only the 5500-24G-4SFP HI (2 slots), 5500-48G-4SFP HI (2 slots), 5500-24G-SFP HI (2 slots), and 5500-24G-SFP HI TAA (2 slots) switches. This task requires two people. To install the switch in a 19-inch rack by using the front mounting brackets: Identify the mounting positions.
  • Page 17: Rack-Mounting By Using Front And Rear Mounting Brackets

    One person supports the chassis bottom with one hand, holds the front part of the chassis with the other hand, and pushes the chassis into the rack gently The other person uses M6 screws and cage nuts (user supplied) to attach the switch to the rack. Figure 18 Mounting the switch to the rack (front mounting brackets at the port side) Figure 19 Mounting the switch to the rack (front mounting brackets at the power side) Rack-mounting by using front and rear mounting brackets...
  • Page 18 Attach the front mounting brackets to the chassis: Unpack the front mounting brackets and the M4 screws for attaching the brackets to the switch chassis. Align the round holes in the wide flange of one front mounting bracket with the screw holes in the port-side mounting position on one side of the chassis (see Figure 20).
  • Page 19: Mounting The Switch On A Workbench

    Mount the switch chassis in the rack: One person supports the chassis bottom with one hand, holds the front part of the chassis with the other hand, and pushes the chassis into the rack gently. Make sure the load-bearing screws closely contact with the upper edges of the rear mounting brackets, as shown in Figure The other person aligns the oval holes in the front brackets with the mounting holes in the front...
  • Page 20: Grounding The Switch

    Grounding the switch WARNING! Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection. The power input end of the switch has a noise filter, whose central ground is directly connected to the chassis to form the chassis ground (commonly known as PGND). You must securely connect this chassis ground to the earth so the faradism and leakage electricity can be safely released to the earth to minimize EMI susceptibility of the switch.
  • Page 21 Figure 23 Connecting the grounding cable to the chassis (1) Grounding cable (2) Grounding sign (3) Grounding hole (4) Ring terminal (5) Grounding screw Check that the grounding cable has been securely connected to the rear grounding point. Remove the hex nut of a grounding post on the grounding strip. Cut the grounding cable as appropriate for connecting to the grounding strip.
  • Page 22: Grounding The Switch With A Grounding Conductor Buried In The Earth Ground

    Grounding the switch with a grounding conductor buried in the earth ground If the installation site has no grounding strips, but earth ground is available, hammer a 0.5 m (1.64 ft) or longer angle iron or steel tube into the earth ground to serve as a grounding conductor. The dimensions of the angle iron must be at least 50 ×...
  • Page 23: Installing/Removing A Power Supply

    Figure 27 Grounding through the PE wire of the AC power cord (1) Chassis rear panel (2) Three-wire AC power cord NOTE: To guarantee the grounding effect, use the grounding cable provided with the switch to connect to the grounding strip in the equipment room as long as possible. Installing/removing a power supply WARNING! In power redundancy mode, you can replace a power supply without powering off the switch but must...
  • Page 24 For the PSR150-A, PSR150-D, PSR150-A1, and PSR150-D1 power supplies, the installation and removal procedures are the same. The following takes the PSR150-A power supply as an example. To install a power supply: Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded.
  • Page 25: Removing A Psr150 Series Power Supply

    Figure 31 Removing the filler panel Removing a PSR150 series power supply To remove a power supply: Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. Disconnect the power cord. Loosen the captive screws of the power supply with a Phillips screwdriver until they are completely disengaged.
  • Page 26: Removing A Psr720-56A/Psr1110-56A Power Supply

    Correctly orient the power supply with the power supply slot (use the letters on the power supply faceplate for orientation), grasp the handle of the power supply with one hand and support its bottom with the other, and slide the power supply slowly along the guide rails into the slot until you hear that the latch of the power supply clicks into the slot.
  • Page 27 Put away the removed power supply in an antistatic bag or the power supply package bag for future use. Install the filler module to prevent dust and ensure proper ventilation if no power supply is installed in the slot. Figure 34 Removing the power supply The switch provides one filler module for the power supply slot.
  • Page 28: Connecting The Power Cord

    Figure 35 Installing a filler module If the power supply slot where you want to install a power supply is covered by a filler module, remove the filler module first. To do so, insert a flathead screwdriver through the handle and pull the filler module outward along the guide rails, as shown in Figure 36.
  • Page 29: Connecting The Psr150-A/Psr150-A1

    Power supply Connection procedure reference PSR150-D (JD366A) Connecting the PSR150-D/PSR150-D1 PSR150-D1 (JD366A) PSR720-56A (JG544A) Connecting the PSR720-56A/PSR1110-56A PSR1110-56A (JG545A) CAUTION: The AC power cord for the PSR150-A/PSR150-A1 uses C13 connector, while the AC power cord for the PSR720-56A/PSR1110-56A uses high-temperature C15 connector. Do not mix them. Connecting the PSR150-A/PSR150-A1 The following takes the PSR150-A as an example.
  • Page 30: Connecting The Psr720-56A/Psr1110-56A

    Connect the two wires at the other end of the power cord to a –48 VDC power source. NOTE: You can also connect the PSR150-D to an HP A-RPS800 (JD183A) or A-RPS1600 (JG136A) RPS, but you must purchase the power cord separately.
  • Page 31: Installing/Removing An Interface Card

    Installing an interface card IMPORTANT: On the 5500-24G-4SFP HI (2 slots), 5500-24G-SFP HI (2 slots), 5500-24G-SFP HI TAA (2 slots), 5500-24G-PoE+-4SFP HI (2 slots), and 5500-24G-PoE+-4SFP HI TAA (2 slots) switches, you can install the LSP5GP8P0 (JG314A) and LSP5GT8P (JG313A) cards only in SLOT1.
  • Page 32 Figure 40 Removing the filler panel over an interface card slot Hold the captive screws on the front panel of the interface card, and gently push the interface card in along the slot guide rails until the interface card is in close contact with the switch chassis (see callout 1 in Figure 41.)
  • Page 33: Removing An Interface Card

    NOTE: The LSP5GT8P (JG313A) interface card adds 34.75 mm (1.37 in) to the depth of the 5500 HI switch. Figure 43 LSP5GP8P0 in the chassis NOTE: The LSP5GP8P0 (JG314A) interface card adds 69.75 mm (2.75 in) to the depth of the 5500 HI switch. Removing an interface card CAUTION: Do not touch the surface-mounted components directly with your hands.
  • Page 34: Verifying The Installation

    Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. Then unpack the dedicated SFP+ cable. Hold the connector at one end of the cable, with the pull latch on top. Orient the connector with the port and insert it into the port. Removing a CX4/SFP+ cable To remove a CX4 or SFP+ cable from a port on a CX4/SFP+ interface card: Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well...
  • Page 35: Accessing The Switch For The First Time

    Accessing the switch for the first time Setting up the configuration environment The first time you access the switch you must use a console cable to connect a console terminal, for example, a PC, to the console port on the switch. Figure 44 Connecting the console port to a terminal Connecting the console cable Console cable...
  • Page 36: Setting Terminal Parameters

    Connect the RJ-45 connector to the console port of the switch. NOTE: Identify the mark on the console port and make sure that you are connecting to the correct port. The serial ports on PCs do not support hot swapping. If the switch has been powered on, connect the console cable to the PC before connecting to the switch, and when you disconnect the cable, first disconnect from the switch.
  • Page 37 Figure 47 Setting the serial port used by the HyperTerminal connection Set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to None, and click OK. Figure 48 Setting the serial port parameters Select File >...
  • Page 38 Figure 49 HyperTerminal window On the Settings tab, set the emulation to VT100 and click OK. Figure 50 Setting terminal emulation in Switch Properties dialog box...
  • Page 39: Powering On The Switch

    After the startup completes, you can access the CLI to configure the switch. NOTE: HP 5500 HI Switch Series For more information about the configuration commands and CLI, see Configuration Guides HP 5500 HI Switch Series Command References...
  • Page 40: Setting Up An Irf Fabric

    Setting up an IRF fabric You can use HP Intelligent Resilient Framework (IRF) technology to connect and virtualize HP 5500 HI switches into a virtual switch called an "IRF fabric" or "IRF virtual device" for flattened network topology, and high availability, scalability, and manageability.
  • Page 41: Planning Irf Fabric Setup

    Configure basic IRF settings See HP 5500 HI Switch Series IRF Configuration Guide. Connect the physical IRF ports on the switches. Use CX4 cables to connect CX4 ports over a short distance. Use XFP transceiver modules and fibers to connect XFP ports over a long distance.
  • Page 42: Identifying The Master Switch And Planning Irf Member Ids

    Figure 52 Figure 53 show the topologies for an IRF fabric made up of three 5500-24G-4SFP HI (2 slots) switches that have two 2-port 10 GE SFP+ interface cards for IRF connections. The IRF port connections in the two figures are for illustration only, and more connection methods are available.
  • Page 43: Identifying Physical Irf Ports On The Member Switches

    IRF connection. Table 6 Physical IRF port requirements Switch model Candidate physical IRF ports Requirements 5500-24G-4SFP HI (2 slots) 5500-24G-SFP HI (2 The two fixed SFP+ ports on slots) the front panel...
  • Page 44: Planning The Cabling Scheme

    "CX4 cables". The following subsections describe several HP recommended IRF connection schemes, and all these schemes use a ring topology. IMPORTANT: In these schemes, all physical IRF ports are located on the same side. If physical IRF ports are on different sides, you must measure the distance between them to select an appropriate cable.
  • Page 45 Figure 54 Connecting the switches in the same rack Figure 55 IRF fabric topology...
  • Page 46: Configuring Basic Irf Settings

    "Installing/removing an interface card." Execute the display irf configuration command to verify the basic IRF settings. For more information about configuring basic IRF settings, see HP 5500 HI Switch Series IRF Configuration Guide. Connecting the physical IRF ports Use CX4/SFP+ cables or XFP/SFP+ transceiver modules and fibers to connect the IRF member switches as planned.
  • Page 47 Use Telnet, web, or SNMP to access the IRF fabric from the network management station. (See HP 5500 HI Switch Series Fundamentals Configuration Guide.) Check that you can manage all member switches as if they were one node. Display the running status of the IRF fabric by using the commands in...
  • Page 48: Maintenance And Troubleshooting

    The LED displays a flashing F character. Seven-segment LED Unit The 5500 HI Switch Series uses fixed fans. If a fan failure occurs, promptly contact HP for help and do not attempt to fix the problem yourself or continue to run the switch. Configuration terminal problems If the configuration environment setup is correct, the configuration terminal displays booting information when the switch is powered on.
  • Page 49 The console cable is properly connected. The console cable has no problem and the terminal settings are correct. Garbled terminal display If terminal display is garbled, verify that the following settings are configured for the terminal, for example, HyperTerminal: Baud rate—9,600 Data bits—8 Parity—none Stop bits—1...
  • Page 50: Appendix A Technical Specifications

    Input voltage Max voltage range: –36 VDC to –72 VDC NOTE: You can use the site –48 VDC power supply or an HP A-RPS800 (JD183A) or A-RPS1600 (JG136A) RPS as the DC power source. AC: 62 W AC: 94 W...
  • Page 51 XFP-LH40-SM1550-F1 or XFP-LH80-SM1550 is used Relative humidity 5% to 95%, noncondensing Fire resistance UL60950-1, EN60950-1, IEC60950-1, GB4943 compliance Table 10 HP 5500 HI switches technical specifications (II) 5500-24G-PoE+-4SFP HI (2 slots)/ 5500-48G-PoE+-4SFP HI (2 slots)/ Item 5500-24G-PoE+-4SFP HI TAA (2 5500-48G-PoE+-4SFP HI TAA (2...
  • Page 52: Cooling System

    For different switch models, design the cooling system as follows: Model Cooling system design 5500-24G-4SFP HI (2 slots) 5500-48G-4SFP HI (2 slots Six fans at most, including three fans for the system, one fan for each power supply, and one for interface card slot SLOT1.
  • Page 53: Appendix B Frus And Compatibility Matrixes

    Appendix B FRUs and compatibility matrixes This appendix describes the field replaceable units (FRUs) available for the 5500 HI switches and their compatibility. All the FRUs in this appendix are hot swappable. FRUs and compatibility matrixes 5500-24G-PoE 5500-48G-P 5500-24G-SF +-4SFP HI (2 oE+-4SFP HI P HI (2 slots)/ 5500-24G-4S...
  • Page 54: Hot Swappable Power Supplies

    MAC address, and vendor of the power supply. For the 5500-24G-4SFP HI (2 slots), 5500-48G-4SFP HI (2 slots), 5500-24G-SFP HI (2 slots), or 5500-24G-SFP HI TAA (2 slots) switch, one power supply can satisfy the normal operation of the switch, and two power supplies can implement 1 + 1 redundant backup.
  • Page 55: Sfp/Sfp+/Xfp Transceiver Modules And Sfp+/Cx4 Cables

    For more information about the interface cards, see their user guides. SFP/SFP+/XFP transceiver modules and SFP+/CX4 cables This section describes the transceiver modules and transceiver module cables available for the HP 5500 HI Switch Series. IMPORTANT: The operating temperature is 0°C to 45°C (32°F to 113°F) for the JD121A and JD107A transceiver modules, and 0°C to 50°C (32°F to 122°F) for all other transceiver modules.
  • Page 56: 1000 Mbps Sfp Transceiver Modules

    Central wavelength Product code Module Description diameter transmission (nm) (μm) distance 50/125 2 km (1.24 miles) HP X115 100M SFP LC FX JD102B 1310 Transceiver 62.5/125 2 km (1.24 miles) HP X110 100M SFP LC LX 15 km (9.32 JD120B 1310...
  • Page 57: 10 Gbps Sfp+ Transceiver Modules/Sfp+ Cables

    HP X120 1G SFP LC 100 km (62.14 JD103A 1550 9/125 LH100 Transceiver miles) TX: 1310 HP X120 1G SFP LC BX 10 km (6.21 JD098B 9/125 10-U Transceiver miles) RX: 1490 TX: 1490 HP X120 1G SFP LC BX 10 km (6.21...
  • Page 58: 10 Gbps Xfp Transceiver Modules

    (μm) (nm) (MHz × km) 2000 300 m (984.25 ft) 50/125 82 m(269.03 ft) HP X130 10G XFP LC JD117B 66 m(216.54 ft) SR Transceiver 33 m (108.27 ft) 62.5/125 26 m (85.3 ft) HP X130 10G XFP LC...
  • Page 59 CX4 Cable HP X230 Local Connect 100cm JD364B 4X Infiniband 1 m (3.28 ft) CX4 Cable JD365A HP X230 CX4 to CX4 3m Cable 4X Infiniband 3 m (9.84 ft) Figure 58 CX4 cable assembly (1) Pull latch (2) Connector...
  • Page 60: Appendix C Ports And Leds

    Appendix C Ports and LEDs Fixed ports Console port Every 5500 HI switch has one console port. Table 11 Console port specifications Item Specification Connector type RJ-45 Compliant standard Asynchronous EIA/TIA-232 Transmission baud rate 9600 bps (default) to 115200 bps Provides connection to an ASCII terminal.
  • Page 61: 100/1000Base-X Sfp Port

    Item Specification Max transmission distance 100 m (328.08 ft) Transmission medium Category-5 (or above) twisted pair cable Standards IEEE 802.3i, 802.3u, 802.3ab 100/1000Base-X SFP port Every 5500 HI switch has four fixed 100/1000Base-X SFP ports. You can install the modules listed in "100 Mbps SFP transceiver modules"...
  • Page 62: Port Mode Led

    Port mode LED The port mode LED indicates the type of information that the network port LEDs are showing. You can use the port LED mode switching button to change the type of displayed port information. Table 16 Port mode LED description LED mark Status Description...
  • Page 63: Management Ethernet Port Led

    System status LED Seven-segment LED (Unit) status Description (SYS) status The LED displays a lowercase c character. The switch is a candidate switch for a cluster. The LED displays a number. The member ID of the switch. The seven-segment LED, the system status LED, and the port mode LED on the 5500-24G-PoE+-4SFP HI (2 slots), 5500-24G-PoE+-4SFP slots),...
  • Page 64: 10/100/1000Base-T Ethernet Port Led

    10/100/1000Base-T Ethernet port LED Each 10/100/1000Base-T auto-sensing Ethernet port has a status LED to show port operating status and activities. The port mode LED indicates the type of port status information (for example, port rate or duplex mode) that the port LEDs are showing. You can use the port LED mode switching button to change the type of displayed port information.
  • Page 65: Sfp+ Port Led

    Port mode LED (Mode) Port LED status Description status Flashing yellow (3 Hz) POST has failed on the port. No link is present on the port. The port is operating in full duplex mode. The port LED Steady green fast flashes when the port is sending or receiving data. Steady yellow (duplex mode) Flashing yellow (3 Hz)
  • Page 66: I/O Status Led On The Power Supply

    The LSPM2SP2P interface card, when used on a 5500 HI switch, supports not only 10 Gbps SFP+ transceiver modules and cables, but also 1000 Mbps SFP transceiver modules. Table 24 describes its LED behaviors. Table 24 Port LED description for the LSPM2SP2P interface card Port mode LED Port LEDs on the Description...
  • Page 67: Support And Other Resources

    Related information Documents To find related documents, browse to the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals For related documentation, navigate to the Networking section, and select a networking category. For a complete list of acronyms and their definitions, see HP FlexNetwork Technology Acronyms.
  • Page 68: Conventions

    Conventions This section describes the conventions used in this documentation set. Command conventions Convention Description Boldface Bold text represents commands and keywords that you enter literally as shown. Italic Italic text represents arguments that you replace with actual values. Square brackets enclose syntax choices (keywords or arguments) that are optional. Braces enclose a set of required syntax choices separated by vertical bars, from which { x | y | ...
  • Page 69 Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features. Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device.
  • Page 70 Configuring basic IRF settings,43 Connecting the console cable,32 Connecting the physical IRF ports,43 Mounting the switch on a workbench,16 Connecting the power cord,25 Contacting HP,64 Planning IRF fabric setup,38 Conventions,65 Power supply failure,45 Cooling system,49 Powering on the switch,36 Examining the installation...

Table of Contents