MAJOR COMPONENTS

2-Stage Compressor
The 2-stage compressor contains motor windings that provide 2-pole
(3500 RPM) operation.
Compressor Internal Relief
The compressor is protected by an internal pressure relief (IPR) which
relieves discharge gas into compressor shell when differential between
suction and discharge pressures exceeds 550 - 625 psi. The compressor
is also protected by an internal overload attached to motor windings.
Compressor Control Contactor
The contactor has a 24 volt coil and is controlled by Y1 input from the
thermostat

CARE AND MAINTENANCE

For continuing high performance and to minimize possible equipment
failure, periodic maintenance must be performed on this equipment.
Frequency of maintenance may vary depending upon geographic areas,
such as coastal applications. See Users Manual for information.

TRAINING

My Learning Center is your central location for professional residential HVAC training resources that help strengthen careers and businesses. We
believe in providing high quality learning experiences both online and in the classroom.
Access My Learning Center with your HVAC Partners credentials at www.mlctraining.com. Please contact us a
mylearning@carrier.com
with
questions.
©
2024 Carrier. All rights reserved.
Edition Date: 11/24
Catalog No: 26TPA8-01SI
Replaces:New
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
12

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Performance 26TPA8 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF