Page 1
Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com Zierikzee, the Netherlands Tel. +31 111 413656 DC POWER SUPPLIES SM3300 - Interfaces • INT MOD M/S • INT MOD SIM • INT MOD CON • INT MOD SER • INT MOD DIG • INT MOD ANA •...
Page 2
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections. Delta Elektronika shall not be liable for user’s failure to comply with these requirements.
Page 3
Warning! High currents can run through the DC power terminals. These currents cause strong magnetic fields. Do not come near if you have an electro medical device such as a pacemaker. 1.15 Environmental Conditions • The Delta Elektronika power supplies safety approval applies to the following operating conditions: • Usage : Indoor use only.
Page 4
Die Nichteinhaltung der Sicherheitsvorkehrungen oder Warnungen in diesem Dokument verstößt gegen die Sicherheitsstandards im Hinblick auf Bauart, Produktion und vorgesehene Nutzung dieses Geräts und kann die eingebauten Schutzvorrichtungen beschädigen. Delta Elektronika haftet nicht dafür, wenn der Nutzer diesen Anforderungen nicht nachkommt.
Page 5
Warnung! Hohe Ströme können durch die DC-Anschlussklemmen laufen. Diese Ströme verursachen starke Magnet- felder. Kommen Sie nicht in die Nähe, wenn Sie ein elektromedizinisches Gerät wie einen Herzschrittmacher haben. 2.15 Umgebungsbedingungen Die Stromversorgungssicherheitszulassung von Delta Elektronika gilt für die folgenden Betriebsbedingungen: • Gebrauch : Nur Innengebrauch.
Page 6
Connectez-vous en permanence au réseau d’alimentation ou via une connexion de prise industrielle conformément à la norme CEI 60309. ‘Équipement connecté en permanence’ ou ‘Équipement enfichable de type B’. Fusibles Les fusibles ne peuvent être remplacés que par le personnel de service autorisé de Delta Elektronika afin d’éliminer définitivement le risque d’incendie. Alimentation d’entrée CA N’utilisez pas une alimentation CA qui dépasse la tension d’entrée CA et la puissance de fréquence de cet appareil.
Page 7
Attention! Des courants élevés peuvent traverser les bornes CC. Ces courants provoquent de forts champs magnétiques. Ne vous approchez pas si vous avez un appareil électromédical comme un stimulateur cardiaque. 3.15 Conditions ambiantes L’approbation de sécurité de l’alimentation de Delta Elektronika s’applique aux conditions de fonctionnement suivantes : •...
Page 8
4 - 1 outlet of the power supply are unobstructed and the All positions are valid for the INT MOD M/S. temperature of the air-intake is not higher than +50°C. • When the power supply is mounted in a cabinet, please note that the temperature of the air-intake should be kept low and avoid a short circuit in the airflow i.e.
• Check the web interface for errors in one of the devices. • Use Ethernet commands to check for errors in the master slave system. CALIBRATION • Calibration of the interface is not applicable. 9 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 10
Position of the interface icon in the unit display. program the CV-settings via this interface, via the front menu go to CONFIGURATION -> SOURCE -> Vsettings and set it to Slot2. 10 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
‘Load’. When you accept the following dialog, the parameters table 5 - 3 from the simulation module are filled in the application. 11 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 12
• All these operating modes are limited by the maximum configurable resistance as specified. • The settings for the leadless sensing simulation can be configured trough the web interface. Within the interfaces page. 12 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 13
5.12.3 INTERFACE DOES NOT CORRECT THE OUTPUT VOLTAGE OR CURRENT • Check if the simulation type is enabled. • Check the simulation interface settings. 13 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 14
• The unit will automatically detect the new inserted interface. • The interface icon will be shown in the display, see fig 6 - 3. fig 6 - 3 Position of the interface icon in the unit display. 14 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 15
• Check Interlock / enable connection on CON K. CALIBRATION fig 6 - 7 • Calibration of the interface is not applicable. 15 - 30 V Enable. fig 6 - 8 Interlock contact (door switch). 15 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
• Connect the mains supply again and check all the safety Pin connections of the RS422 / RS485 connector. covers are installed. • Switch on the unit. • The LED should light up. 16 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
• Check that the communication is working; "*IDN?" must return Available serial programming commands. a value. Ensure to end the query with the termination character LF. • (LF = 0x0Ah in ASCII) 17 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 18
• Port settings on the PC. o Baudrate : bps 9600 o Data bits : 8 o Parity bits : None o Stop bits : 1 o Flow control : None 18 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 19
• The LED indicated in fig. 8 - 2 will light up. UNIT CONFIGURATION • The unit will automatically detect the new inserted interface. • The interface icon will be shown in the display, see fig 8 - 3. 19 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Sequencer to make the power supply act like a Power PLC. • Refer to the Delta Elektronika programming manual for Ethernet (section 6) & Sequencer (section 7) for commands. • The manual is stored inside every SM3300 unit and can be downloaded via the web interface.
Page 21
• The pinning of the INT MOD ANA is similar to other Delta Elektronika power supplies, see fig 9 - 2. • Connect the mains supply again and check all the safety covers are installed. • Switch on the unit. 21 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
• The table in the interface datasheet shows the impedance levels of the monitoring outputs. • The monitoring outputs can drive a meter directly (fig. 9 - fig 9 - 7 Remote control. 22 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
• The isolated analog interface is factory calibrated. • If desired, both the 5 V and 10 V range can be custom calibrated. See the ethernet programming manual for more details. 23 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
Page 24
• Unscrew the 2 ‘Torx T10 screws’ and remove the slot cover of the power supply. • Insert the INT MOD ANY, with the AnyBus module installed. • Use the two ‘Torx T10 screws’ to secure the INT MOD ANY. 24 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...
• Check the source of the power supply. • Check the web interface of the unit for errors. • Use Ethernet or web commands to check for errors. 10.11 CALIBRATION • Calibration of the interface is not applicable. 26 / 26 DELTA ELEKTRONIKA B.V. rev. April 2025...