Eaton CROUSE-HINDS HRL3060 Series Instruction Manual
Eaton CROUSE-HINDS HRL3060 Series Instruction Manual

Eaton CROUSE-HINDS HRL3060 Series Instruction Manual

Hazardous recessed led lighting

Advertisement

Instruction manual
IM1465
Rev.6
Hazardous recessed
LED Lighting

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CROUSE-HINDS HRL3060 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton CROUSE-HINDS HRL3060 Series

  • Page 1 Instruction manual IM1465 Rev.6 Hazardous recessed LED Lighting...
  • Page 2: Safety Instructions

    II2 D Ex tb IIIC T80℃ Db(For all types) luminaire nameplate. The luminaires shall be operated as intended and only in undamaged and  ‐40ºC~+55 ºC‐‐‐ Normal Version Ambient  perfect conditions! And Keep tightly closed when in operation! temperature: ‐25ºC~+55 ºC‐‐‐ EM version The technical data indicated on the luminaire are to be observed! Temperature  Change of the design and modifications to the luminaire are not permitted! class: Multiple, short‐term switching must be observed!  ATEX/IECEx  SEV 19 ATEX 0101X/ Only genuine Eaton Crouse‐Hinds spare parts may be used for replacement! Certificate No.: IECEx SEV 19.0001X Repairs that affect the explosion protection, may only be carried out by  Degree of  Eaton Crouse‐Hinds or qualified electrician! IP 66 acc. to EN60529/IEC60529  Potential electrostatic risk clean only with a damp cloth protection: Enclosure specification 2. Conformity with standards Material of  Galvanized steel This explosion protection floodlight meet the requirements  of IEC/EN 60079‐ enclosure: SS316L 0, IEC/EN 60079‐1, IEC/EN 60079‐7,  IEC 60079‐11, IEC 60079‐18, IEC/EN ...
  • Page 3: Mounting Luminaire

    Open the cover with PC cover. And carry out the steps in reverse order to close  these must be replaced with factory specified parts.  the luminaire. Check all screws to ensure a secure fit during operation . No modifications should be made without the knowledge and approval of the  6.5 Electrical connection manufacturer. The electrical connection of the lamp must only be established by qualified  Cleaning the joint of housing assy. and pc cover use a damp cloth or a mild  electricians.  cleaning fluid. Make sure the supply voltage is the same as the luminaire voltage! Use proper  supply wiring as specified on the nameplate of the luminaire and in this  9. Repair/Overhaul/Modifications instructions! Excessive tightening may affect or damage the connection. 9.1 General 6.5.1 Wire connection  The national regulations EN/IEC60079‐19 have to be observed! Repairs and  The conductors shall be connected with special care in order to maintain the  overhaul may only be carried out with genuine Eaton Crouse‐Hinds spare  explosion category.   parts. The conductor itself shall not be damaged.  In the case of battery failure, the battery pack must be replaced as a  The connectible min. and max. conductor cross‐sections shall be observed (see  complete unit  from the manufacture. technical data).  All terminals, used and unused, shall be fully tightened to  Before replacing or disassembling individual parts, observe the following: prevent incorrect selection between 1.2Nm for Exe T 6P and 1.5~1.8Nm for  Disconnect the power supply to the equipment before maintenance/repair.  MBK. Main connection: See wiring diagram. See Fig.4 for details. Make sure that there is no explosive atmosphere when opening the  6.6 Emergency light attention: equipment. See section 8.4 for notes on opening and closing the lamp. In mains operation the light fitting is charged by means of constant current  Only use original spare parts. If the luminaire was previously in operation  output from inverter. Charging takes place via the un‐switched external phase  then wait to cool enough before opening. Repairs that affect the explosion  L to prevent an interruption, even when the luminaire is switched off.
  • Page 4 11.Dimension IM1465 Rev.6 2024/12 Cooper Electric (Changzhou) Co., Ltd. Page3/7...
  • Page 5 12.Wire diagram IM1465 Rev.6 2024/12 Cooper Electric (Changzhou) Co., Ltd. Page4/7...
  • Page 6 13.ILLUSTRATIONS FOR MOUNTING Continuous ceiling fig.1 fig.2 Gap Ceiling fig.3 IM1465 Rev.6 2024/12 Cooper Electric (Changzhou) Co., Ltd. Page5/7...
  • Page 7 fig.4 14. Type configuration and Max. Ambient and Temperature Ratings Color System LED  T Class T ℃ Voltage Tamb. Weight Enclosure  Std. Cat No. (ºC) (kg) Temp. Outline power Qty. (Gas) (Dust) ‐40~+55 HRL/3060/30w/*/*//*/* 275*605*121 ‐25~+55 10.4 HRL/3060/30w/*/*/EM*/*/* 3000K 100‐240Vac ‐40~+55 HRL/3012/60w/*/*//*/* 4000K 275*1215*121 50/60Hz ‐25~+55 5000K...
  • Page 8 IM1465 Rev.6 2024/12 Cooper Electric (Changzhou) Co., Ltd. Page7/7...

This manual is also suitable for:

Crouse-hinds hrl3012 seriesCrouse-hinds hrl6060 seriesCrouse-hinds hrl/3060/30w seriesCrouse-hinds hrl/3060/30w/em seriesCrouse-hinds hrl/3012/60w seriesCrouse-hinds hrl/3012/60w/em series ... Show all

Table of Contents