Multi-Position & Hydronic Air Handlers
Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

TABLE OF CONTENTS

Air Handler Safety ................................................................ 1
General ................................................................................ 2
Wiring Diagram .................................................................... 3
Thermostat Connections ...................................................... 4
Blower Performance Data .................................................... 7
Inspect Shipment ................................................................. 9
Tools and Parts .................................................................... 9
Outdoor System Requirements............................................ 9
Location Requirements ........................................................ 9
Installation Clearances....................................................... 10
Configuration Options ........................................................ 10
Drain Pan Connections ...................................................... 11
Electrical Requirements ..................................................... 12
Ductwork Requirements..................................................... 12
Install Ductwork.................................................................. 12

AIR HANDLER SAFETY

SAFETY CONSIDERATIONS
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and
on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt
you and others.
All safety messages will follow the safety alert symbol and signal word.
These signals words mean the following:
DANGER: You can be killed or seriously injured if you don't
immediately follow instructions.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised ensure that they do not play with the appliance.
Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice
and without obligation on our part. Please contact your ADP representative or distributor to verify details.
B Series
PAGE
CAUTION
© 2025 by Advanced Distributor Products. All rights reserved.
2140 Lake Park Blvd, Richardson, TX 75080
1
www.adpnow.com
Installation Instructions
Sloping the Drain ...............................................................12
Install Condensate Drain ....................................................13
Metering Device .................................................................14
Label Installation ................................................................14
Refrigerant Line Installation ...............................................15
Refrigerant Charging Instructions ......................................15
Supply Voltage Connections ..............................................16
Variable Speed Control Board ...........................................16
Hot Water Coil Installation .................................................17
Hot Water Coil Flushing .....................................................18
Sequence of Operation ......................................................19
Air Handler Maintenance ...................................................19
Assistance or Service ........................................................19
Air Handler Checks ............................................................20
Warranty ............................................................................20
WARNING: Indicate a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. Caution may also
be used to alert against unsafe practices.
NOTICE: Indicates a statement of company policy as the message
relates directly or indirectly to the safety of personnel or protection of
property.
IMPORTANT: More detailed information concerning the statement of
company policy as the message relates directly or indirectly to the
safety of personnel or protection of property.
IM-BAH-0662402-19
November 2024
PAGE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Adp B Series

  • Page 1: Table Of Contents

    Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice and without obligation on our part. Please contact your ADP representative or distributor to verify details. © 2025 by Advanced Distributor Products. All rights reserved.
  • Page 2: General

    AIR HANDLER SAFETY IMPORTANT IMPORTANT This unit is a PARTIAL UNIT AIR CONDITIONER, complying Improper installation, adjustment, alteration, service or mainte- with PARTIAL UNIT requirements of this Standard, and must nance can cause property damage, personal injury or loss of only be connected to other units that have been confirmed as life.
  • Page 3: Wiring Diagram

    WIRING DIAGRAM Part Number: 67829400 | WIRING DIAGRAM, B SERIES, 120 V / 240 V, PSC / ECM, HW / EH...
  • Page 4: Thermostat Connections

    THERMOSTAT CONNECTIONS 3-Speed Motor (Electric Heat) Maximum allowable current draw from power-stealing thermostats or other accessories is 18 mA. Exceeding this value may cause the Air Handler control board to operate abnormally. Cooling Only Cooling Application Application With Electric Heat NEC CLASS 2 Wiring NEC CLASS 2 Wiring Heating Only...
  • Page 5 THERMOSTAT CONNECTIONS 3-Speed Motor & Variable-Speed High Efficiency ECM Motor (Hot Water Heat) Maximum allowable current draw from power-stealing thermostats or other accessories is 18 mA. Exceeding this value may cause the Air Handler control board to operate abnormally. Hot Water Heat Only Cooling Application Application with Hot Water Heat...
  • Page 6 THERMOSTAT CONNECTIONS Variable-Speed High Efficiency ECM Motor (Electric Heat) Maximum allowable current draw from power-stealing thermostats or other accessories is 18 mA. Exceeding this value may cause the Air Handler control board to operate abnormally. Electric Heat Only Cooling Only Application Application NOTE: For variable speed motor with single-stage condensing unit,...
  • Page 7: Blower Performance Data

    BLOWER PERFORMANCE DATA 3-Speed Motor All data is given while air handler is operating with a dry DX coil and air filter installed. Speeds marked in bold with asterisk* are the factory speed settings for both heating and cooling. Heating speeds should not be reduced below factory setting. 208/240V Motor Airflow (CFM) vs.
  • Page 8 BLOWER PERFORMANCE DATA Variable-Speed High Efficiency ECM Motor Thermostat Terminals Control Board Taps Unit Operating X = Energized Terminal Cool Heat Size Mode MBUTH) Continuous Blower 1000 Hi Cooling / HP Heating Low Cooling/ HP Heating 1000 700* 600* Aux. Heat 1000 700* 600*...
  • Page 9: Inspect Shipment

    INSPECT SHIPMENT If damage is found, it should be noted on the carrier’s freight bill. Damage claims should be filed with the carrier WARNING immediately. Claims of shortages should be filed with the seller within 5 days. Excessive Weight Hazard NOTE: If any damages are discovered and reported to the Use two or more people to move and install air handler.
  • Page 10: Installation Clearances

    INSTALLATION CLEARANCES Clearance to combustible material to be 0 inches to unit casing, • If the free area is not known, assume a 25% free area for and 0 inches to plenum and duct for first 36 inches. wood or a 75% free area for metal louvers or grilles. The air handler can be installed in a closet with a false bottom •...
  • Page 11: Drain Pan Connections

    DRAIN PAN CONNECTIONS Horizontal installations can be either “Right” or “Left.” 6. Remove the screws holding the coil bracket to the left side of top plate. Reposition coil support bracket to right For horizontal right installations, a drain pan location change side of top plate.
  • Page 12: Electrical Requirements

    ELECTRICAL REQUIREMENTS NOTE: Use copper conductors only. WARNING • All field wiring must be done in accordance with National Electrical Code, applicable requirements of UL and local Electrical Shock codes, where applicable. Disconnect power before servicing. • Electrical wiring, disconnect means and over-current pro- Replace all parts and panels before operating.
  • Page 13: Install Condensate Drain

    INSTALL CONDENSATE DRAIN The air handler is provided with ¾" NPT condensate drain 5. Route the drain line to the outside or to an appropriate connections. drain. Drain lines must be installed so they do not block service access to the front of the air handler. A 24" A field fabricated secondary drain pan, with a drain pipe to the clearance is required for filter, coil, or blower removal and outside of the building, is required in all installations over a...
  • Page 14: Metering Device

    METERING DEVICE Pistons Thermal Expansion Valve (TXV) As shipped from the factory, the piston installed in each coil is Some models are equipped with a factory installed thermal chosen for the nominal BTUH capacity of the coil. A label on expansion valve.
  • Page 15: Refrigerant Line Installation

    Do not remove the caps from the lines or system connection points unit connections are ready to be ADP recommends installing a filter drier and sight glass in the completed. liquid line. While brazing, purge the system with Nitrogen to prevent contamination.
  • Page 16: Supply Voltage Connections

    SUPPLY VOLTAGE CONNECTIONS WARNING Unit Size (MBTUH) Electric Heat Kit (kW) Electrical Shock 18, 24 Disconnect power before servicing. Replace all parts and panels before operating. Electrically ground air handler. 17.5 Connect ground wire to ground terminal marked Failure to do so can result in death or electrical shock. 36, 37, 42, 48, 60 Table: Maximum allowable kW Electric Heat Kits that can be Explosion Hazard...
  • Page 17: Hot Water Coil Installation

    HOT WATER COIL INSTALLATION ADP hydronic air handlers (certified to NSF 372) can be used 1. Determine Volume with potable water systems and are shipped with or without Water Heater circulating pumps. Kits are also available. Refer to pipe and Requirements pump sizing in the Air Handler’s Engineering &...
  • Page 18: Hot Water Coil Flushing

    The Blower Door Safety Switch circuit must be complete for all Sequence of Operations to take place. FIGURE 11 Drawing of Multi-function Control Board, installed in all B Series Air Handlers NOTE: Please take precautions while installing the Air Handler to...
  • Page 19: Air Handler Maintenance

    This pump timer requirement is a standard factory installed feature on all B Series Air Handlers. When the thermostat calls for heat, the circuits between R and Y The Pump timer activates the circulating pump or isolation and R and G are completed.
  • Page 20: Air Handler Checks

    ADP AIR HANDLER LIMITED WARRANTY Term of Warranty Equipment Information Advanced Distributor Products (ADP) warrants that products Please complete information below and retain this warranty for records and future reference. sold shall be of merchantable quality, free of defects in material...
  • Page 21: Sécurité Du Ventilo-Convecteur

    L’amélioration des produits est un processus continu chez Advanced Distributor Products. Par conséquent, les spécifications du produit peuvent être modifiées sans préavis et sans obligation de notre part. Veuillez contacter votre représentant ou distributeur ADP pour vérifier les détails. © par Advanced Distributor Products. Tous droits réservés.
  • Page 22: Généralités

    SÉCURITÉ DU MANUTENTEUR D’AIR IMPORTANT IMPORTANT Cette unité est un CLIMATISEUR À UNITÉ PARTIELLE, IUne installation, un réglage, une modification, une conforme aux exigences de la présente norme, et ne doit être maintenance et/ou un entretien incorrects peuvent entraîner connectée qu’à d’autres unités qui ont été confirmées comme des dommages matériels ou des blessures graves, voire étant conformes aux exigences de la présente norme UL 60335-2 mortelles.
  • Page 23: Schéma De Câblage

    SCHÉMA DE CÂBLAGE Référence : 67829400 | SCHÉMA DE CÂBLAGE, SÉRIE B, 120 V / 240 V, PSC / ECM, HW / EH...
  • Page 24: Connexions Du Thermostat

    CONNEXIONS DU THERMOSTAT Moteur 3-Speed (chauffage électrique) La consommation de courant maximale autorisée des thermostats à vol d’énergie ou d’autres accessoires est de 18 mA. Un dépassement de cette valeur peut entraîner un fonctionnement anormal du panneau de commande du ventilo-convecteur. Application de climatisation Application de climatisation uniquement...
  • Page 25 CONNEXIONS DU THERMOSTAT Moteur 3-Speed et moteur ECM haute efficacité à vitesse variable (chauffage à l’eau chaude) La consommation de courant maximale autorisée des thermostats à vol d’énergie ou d’autres accessoires est de 18 mA. Un dépassement de cette valeur peut entraîner un fonctionnement anormal du panneau de commande du ventilo-convecteur. Application Chauffage à...
  • Page 26 CONNEXIONS DU THERMOSTAT Moteur ECM haute efficacité à vitesse variable (chauffage électrique) La consommation de courant maximale autorisée des thermostats à vol d’énergie ou d’autres accessoires est de 18 mA. Un dépassement de cette valeur peut entraîner un fonctionnement anormal du panneau de commande du ventilo-convecteur. Application chauffage Application de électrique uniquement...
  • Page 27: Données De Rendement Du Ventilateur

    DONNÉES DE PERFORMANCE DU VENTILATEUR Toutes les données sont données quand le ventilo-convecteur fonctionne avec un serpentin DX sec Moteur 3-Speed et un filtre à air installés. Les vitesses indiquées en gras avec un astérisque* sont les réglages usine pour le chauffage et la climatisation.
  • Page 28 DONNÉES DE PERFORMANCE DU VENTILATEUR Moteur ECM haute efficacité à vitesse variable Bornes du thermostat Taps du contrôleur Taille de Mode de X = Borne sous tension Climatisation Chauffage l’unité fonctionnement (MBUTH) débit débit débit débit débit débit débit débit Ventilateur continu Climatisation élevée / 1000...
  • Page 29: Inspecter L'expédition

    INSPECTER L’EXPÉDITION En cas de dégâts, ces dégâts doivent être indiqués sur la liste de colisage du transporteur. Les demandes de dommages AVERTISSEMENT doivent être déposées immédiatement auprès du carrier. Les demandes de pénurie doivent être déposées auprès du Risque de poids excessif vendeur dans un délai de 5 jours.
  • Page 30: Dégagements D'installation

    DÉGAGEMENTS D’INSTALLATION Le dégagement par rapport aux matériaux combustibles doit • Si la zone libre n’est pas connue, supposer une zone libre être de 0 po par rapport au corps de l'unité et de 0 po par de 25 % pour le bois ou une zone libre de 75 % pour les rapport au plénum et à...
  • Page 31: Connexions De La Cuvette De Drainage

    CONNEXIONS DE LA CUVE DE DRAINAGE 6. Retirer les vis maintenant le support du serpentin sur le côté gauche de la plaque supérieure. Repositionner le support Pour les installations horizontales à droite, il peut être du serpentin sur le côté droit de la plaque supérieure. nécessaire de changer l’emplacement de la cuvette de drainage.
  • Page 32: Exigences Électriques

    EXIGENCES ÉLECTRIQUES REMARQUE : Utiliser uniquement des conducteurs en cuivre. AVERTISSEMENT • Tout câblage place doit être effectué conformément National Electrical Code, Choc électrique exigences applicables de UL et aux codes locaux, le cas Couper l’alimentation électrique avant de échéant. procéder à...
  • Page 33: Installation Du Drain De Condensat

    INSTALLATION DU DRAIN DE CONDENSAT Le ventilo-convecteur est fourni avec des raccords de drainage 5. Acheminer la conduite de drainage jusqu'à l’extérieur ou de condensat NPT de ¾ po. un drain approprié. Les conduites de drainage doivent être installées de manière à ne pas bloquer l'accès Un bac de drainage secondaire fabriqué...
  • Page 34: Dispositif De Mesure

    DISPOSITIF DE PRÉLÈVEMENT Pistons Vanne d’expansion thermique (TXV) Comme expédié en usine, le piston installé dans chaque ser- Certains modèles sont équipés d’un vanne d’expansion pentin est choisi pour la capacité nominale en BTUH du ser- thermique installé en usine. Le bulbe de détection de la vanne pentin.
  • Page 35: Installation De La Conduite De Réfrigérant

    à être effectuées. 1. Acheminer les conduites d'aspiration et de liquide des ADP recommande d’installer un filtre déshydrateur et une vitre raccords du serpentin intérieur aux raccords de l'unité dans la conduite de liquide.
  • Page 36: Connexions De La Tension D'alimentation

    CONNEXIONS DE LA TENSION D’ALIMENTATION Ensemble de chauffage AVERTISSEMENT Taille de l’unité (MBTUH) électrique (kW) Choc électrique 18, 24 Couper l’alimentation électrique avant de procéder à l’entretien. Remettre toutes les pièces et panneaux en place avant 17.5 de les utiliser. Mettre le ventilo-convecteur à...
  • Page 37: Installation Du Serpentin D'eau Chaude

    INSTALLATION DU SERPENTIN D’EAU CHAUDE Les ventilo-convecteurs hydroniques ADP (certifiés NSF 372) 1. Déterminer le volume peuvent être utilisés avec des systèmes d’eau potable et sont Chauffe-eau expédiés avec ou sans pompes à circulation. Des ensembles pi3/min Exigences sont également disponibles. Voir le dimensionnement des...
  • Page 38: Séquence De Fonctionnement

    RINÇAGE À L’EAU CHAUDE DU SERPENTIN Le rinçage du serpentin d’eau chaude avant le démarrage est pour rincer le serpentin d’eau chaude après l’installation. nécessaire pour retirer tout matériau résiduel des processus Prendre des précautions lors du rinçage du ventilo-convecteur d’installation ou de fabrication, ainsi que tout air du système.
  • Page 39: Entretien Du Ventilo-Convecteur

    SÉQUENCE DE FONCTIONNEMENT circuits R et O ou R et B mettent le vanne d’inversion sous pour démarrer le moteur du ventilateur extérieur et le compresseur. tension, le mettant en position de chauffage (en fonction de l’unité Les circuits R et G mettent le relais du ventilateur sous tension en extérieure).
  • Page 40: Vérifications Du Ventilo-Convecteur

    Durée de la garantie Information sur l’équipement Veuillez écrire les renseignements demandés ci-dessous et Advanced Distributor Products (ADP) garantit que les produits conserver la présente garantie dans vos dossiers, pour vendus seront de qualité marchande, exempts de défauts de consultation future.