Adp HE Series Installation Instructions Manual

Evaporator coils

Advertisement

Available languages

Available languages

Quick Links

TABLE OF CONTENTS
General ........................................................... 5
Location and Clearances ................................ 5
Vertical ............................................................ 6
Horizontal ........................................................ 6
Multi-Position .................................................. 7
Suspended Coil Detail .................................... 9
Condensate Drain ......................................... 10
Coil Cleaning ................................................ 10
Label Installation ........................................... 10
Metering Device ............................................ 11
Refrigerant Line Installation .......................... 11
Flammable Refrigerant Detection ................. 12
Refrigerant Charging instructions ................. 12
Refrigerant Recovery .................................... 13
Maintenance and repair Instructions ............. 13
Warranty ....................................................... 14
Installation Check List ................................... 14
Evaporator Coil Safety
SAFETY CONSIDERATIONS
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on
your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt
you and others.
All safety messages will follow the safety alert symbol and signal word.
These signals words mean the following:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
**
Evaporator Coils
HE, HH, HD, V Series
PAGE
CAUTION
2175 West Park Place Blvd., Stone Mountain, GA 30087
www.adpnow.com
Installation Instructions
DANGER: You can be killed or seriously injured if you don't immediately
follow instructions.
WARNING: Indicate a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. Caution may also be used to
alert against unsafe practices.
NOTICE: Indicates a statement of company policy as the message relates
directly or indirectly to the safety of personnel or protection of property.
IMPORTANT: More detailed information concerning the statement of
company policy as the message relates directly or indirectly to the
safety of personnel or protection of property.
Product improvement is a continuous process at Advanced Distributor
Products. Therefore, product specifications are subject to change without
notice and without obligation on our part. Please contact your ADP
representative or distributor to verify details.
© 2024 by Advanced Distributor Products. All rights reserved.
IM-HAC-0966540-19
March 2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Adp HE Series

  • Page 1 Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice and without obligation on our part. Please contact your ADP representative or distributor to verify details. © 2024 by Advanced Distributor Products. All rights reserved.
  • Page 2 Evaporator Coil Safety CAUTION IMPORTANT Any service personnel installing, decommissioning, or per- This unit is a PARTIAL UNIT AIR CONDITIONER, complying forming maintenance on the unit must be properly trained with with PARTIAL UNIT requirements of this Standard, and must only be connected to other units that have been confirmed as A2L refrigerants complying to corresponding PARTIAL UNIT requirements of...
  • Page 3 Evaporator Coil Safety IMPORTANT IMPORTANT Work shall be undertaken under a controlled procedure so as Where electrical components are being changed, they shall be to minimize the risk of a flammable gas or vapor being present fit for the purpose and to the correct specification. At all times while the work is being performed.
  • Page 4 Evaporator Coil Safety WARNING NOTICE Auxiliary devices which may be a potential ignition source shall All maintenance staff and others working in the local area shall not be installed in the duct work. Examples of such potential be instructed on the nature of work being carried out with work ignition sources are hot surfaces with a temperature exceeding in confined spaces being avoided.
  • Page 5 GENERAL ADP evaporator coils are designed for use with AC condensing units or heat pump units. These instructions are intended as a general guide and do not supersede local codes in any way. Consult with local authorities having jurisdiction before installation.
  • Page 6 VERTICAL Vertical A-Coils are designed for upflow and downflow insulation to the cabinet. This tape will prevent the possibility applications. Vertical drain pans have drain connections on of the insulation delaminating and blocking airflow. the right and left front side of the evaporator coil. Refer to Specification Guide recommended...
  • Page 7 MULTI-POSITION Multi-Position A-Coils come factory installed with a vertical and FIGURE 5 horizontal drain pans and can be configured for upflow, downflow, horizontal blow-through or horizontal pull-through Multi-Position Configurations installations. In the center opening of vertical drain pan, a metal Inlet Air Restrictor is factory installed and is required for horizontal applications.
  • Page 8 MULTI-POSITION (splash guard) FIGURE 7 FIGURE 6 Splashguard without Front Slope Splashguard with Front Slope Seal splashguard seams Holes used to mount with silicone or other sealant. splashguard to duct flanges. Splashguard Splashguard Open end of splashguard should Caution: These holes are for manufacturing purposes only. DO NOT use for installation! rest on the horizontal drain pan.
  • Page 9 MULTI-POSITION (field conversion) MULTI-POSITION (field conversion) Field Conversion Instructions from Left-to-Right or Right-to-Left Airflow Note: This applies only to models available in multi-position; see Specification Guide for details; typical horizontal left-to-right conversion is shown. FOR EACH STEP, REFER TO FIGURE 8: Slide the coil assembly back into the housing (Note: Remove front panels.
  • Page 10 Do not spray the coil from a horizontal direction. LABEL INSTALLATION Permanently mark the serial label with the appropriate A1 (R-410A & R-22)refrigerant & metering device used. See example below. For A2L (R-454B & R-32) installations refer to the ADP’s Refrigerant Detection System Kit for instructions.
  • Page 11 REFRIGERANT LINE INSTALLATION If installing the coil in a system using A2L refrigerants. DO NOT BRAZE ANY LINE SETS without reviewing ADP’s Refrigerant Detection System Kit Installation manual for specific requirements on primary and secondary joints within the installed spaces.
  • Page 12 Outdoor 60 65 70 75 80 95 100 105 110 115 Air Temp. (°F) ADP coils may require charge compensation due to size variation versus the OEM coil. Superheat (°F) 31 28 25 22 20 Temperatures are ±2°F unless otherwise recommended.
  • Page 13 REFRIGERANT RECOVERY Before carrying out work on systems containing refrigerant, it is essential that the technician is completely familiar with the equip- ment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant.
  • Page 14 ADP LIMITED WARRANTY Term of Warranty  Equipment Information Advanced Distributor Products (ADP) warrants that products Please complete information below and retain this warranty for sold shall be of merchantable quality, free of defects in material records and future reference. and workmanship, under normal use and service, for a period...
  • Page 15: Table Of Contents

    Products. Par conséquent, les spécifications des produits sont sujettes à modification sans préavis et sans obligation de notre part. Veuillez contacter votre représentant ou distributeur ADP pour vérifier les détails. © 2024 par Advanced Distributor Products. Tous droits réservés. 2175 West Park Place Blvd., Stone Mountain, GA 30087...
  • Page 16 Sécurité relative à l’évaporateur AVIS ATTENTION Cette unité, est un CLIMATISEUR PARTIEL, conforme aux Tout le personnel qui installe, retire du service ou entretient exigences DES UNITÉS PARTIELLES de la présente norme; l'unité doit être correctement formé aux réfrigérants A2L. elle ne doit être raccordée qu'à...
  • Page 17 Sécurité relative à l’évaporateur IMPORTANT IMPORTANT Les travaux doivent être entrepris selon une procédure con- Lorsque des composants électriques sont remplacés, ils doi- trôlée afin de minimiser le risque de présence d'un gaz ou vent être adaptés à l'usage prévu et conformes aux spécifica- d'une vapeur inflammable pendant l'exécution des travaux.
  • Page 18 Sécurité relative à l’évaporateur AVERTISSEMENT AVIS Aucun dispositif auxiliaire pouvant être une source d'inflamma- Tout le personnel de maintenance et les autres personnes tion potentielle ne doit pas être installé dans les conduits. Des travaillant dans la zone doivent être informés de la nature des exemples de telles sources d'inflammation potentielles sont les travaux effectués, en évitant de travailler dans des espaces surfaces chaudes dont la température dépasse 700 °C et les...
  • Page 19: Généralités

    GÉNÉRALITÉS Les serpentins d’évaporateur ADP sont conçus pour être utilisés avec des climatiseurs ou des thermopompes. Ces instructions contiennent des directives générales, mais n’ont aucunement vocation à supplanter les codes locaux. Consultez les organismes locaux compétents avant l’installation. Lisez ce manuel d’installation et tous les messages de sécurité avant d’installer le serpentin d’évaporateur.
  • Page 20: Vertical

    VERTICAL Les serpentins en A verticaux sont conçus pour les configurations ruban d'aluminium doit être appliqué pour étanchéifier le bord ascendantes et descendantes. Les bacs de drainage verticaux supérieur de l'isolation sur l'enceinte. Ce ruban évite que l'isolant présentent des connexions sur les côtés avant droit et gauche du ne se décolle et bloque le débit d'air.
  • Page 21: Multi-Positions

    MULTI-POSITIONS Les serpentins en A multi-positions sont installés en usine avec un FIGURE 5 bac de drainage vertical et horizontal et peuvent être configurés pour des configurations ascendantes, descendantes, horizontales Configurations multi-positions à air soufflé ou horizontales à air aspiré. Un restricteur d'air d'admission métallique est installé...
  • Page 22 MULTI-POSITIONS (PROTECTION ANTI-ÉCLABOUSSURES) FIGURE 7 FIGURE 6 Protection anti-éclaboussures Protection anti-éclaboussures sans bord incliné avant avec bord incliné avant Étanchéifier les joints de la protection anti- Trous utilisés pour fixer la protection éclaboussures avec du silicone ou un anti-éclaboussures sur les brides produit d'étanchéité.
  • Page 23: Détail D'un Serpentin Suspendu

    MULTI-POSITIONS (CONVERSION MULTI-POSITIONS (CONVERSION SUR PLACE) Instructions de conversion sur place pour un débit d'air de gauche à droite ou de droite à gauche Remarque : Applicable uniquement aux modèles multi-positions ; voir le Guide des spécifications pour plus de détails ; la conversion de gauche à...
  • Page 24: Drain De Condensat

    Marquez de manière permanente l'étiquette de série avec le réfrigérant A1 approprié et le dispositif de mesure utilisé. Voir l'ex- emple ci-dessous. Pour les installations A2L, référez-vous au manuel du kit de système de détection de réfrigérant d'ADP pour les instructions.
  • Page 25: Dispositif De Mesure

    Si vous installez la bobine dans un système utilisant des réfrigérants A2L, NE SOUDEZ AUCUN DES ENSEMBLES DE TUYAUX sans avoir préalablement examiné le manuel d'installation du kit de système de détection de réfrigérant d'ADP pour connaître les exigences spécifiques concernant les joints primaires et secondaires dans les espaces in- stallés.
  • Page 26: Détection De Réfrigérant Inflammable

    Les méthodes de chargement du FEO varient en fonction l'unité extérieure. Alternativement, pour les installations de de la conception et de l’application. Vérifiez que toutes les réfrigérant A1, ADP recommande de charger selon le tableau valeurs de pression, température, sous-refroidissement et de surchauffage ci-dessous.
  • Page 27: Récupération Du Réfrigérant

    RÉCUPÉRATION DU RÉFRIGÉRANT Avant de travailler sur des systèmes contenant du réfrigérant, il est essentiel que le technicien soit parfaitement familiarisé avec l'équipement et tous ses détails. Il est recommandé de récupérer tous les réfrigérants en toute sécurité. Avant de commencer le travail, un échantillon d'huile et de réfrigérant doit être prélevé...
  • Page 28: Garantie

    GARANTIE LIMITÉE D’ADP Période de garantie Information sur l’équipement Advanced Distributor Products (ADP) garantit que les produits Écrivez les renseignements demandés ci-dessous et con- vendus sont de qualité marchande et exempts de défauts de servez la présente garantie dans vos dossiers pour consulta- matière et de fabrication, dans des conditions d’utilisation et...

This manual is also suitable for:

Hh seriesHd seriesV series

Table of Contents