Adp CP18 Installation Instructions Manual

Soffit mount compact ceiling mount air handlers
Hide thumbs Also See for CP18:

Advertisement

Available languages

Available languages

Quick Links

Electric or No Heat, with available 5-Speed High Efficiency ECM Motor
TABLE OF CONTENTS
Air Handler Safety ............................................................... 1
General ................................................................................ 2
Outdoor System Requirements.....................................2
Wiring Diagrams .................................................................. 3
Thermostat Connections ..................................................... 5
Electrical Data ..................................................................... 6
Blower Performance Data ................................................... 7
Receiving ............................................................................. 8
Tools and Parts Needed ...................................................... 8
Installation ........................................................................... 8
Ductwork ............................................................................. 9
Install Condensate Drain ..................................................... 9
AIR HANDLER SAFETY
SAFETY CONSIDERATIONS
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and
on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt
you and others.
All safety messages will follow the safety alert symbol and signal word.
These signals words mean the following:
DANGER: You can be killed or seriously injured if you don't
immediately follow instructions.
WARNING: Indicate a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised ensure that they do not play with the appliance.
Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice
and without obligation on our part. Please contact your ADP representative or distributor to verify details.
Soffit Mount
Compact Ceiling Mount Air Handlers
PAGE
CAUTION
© by Advanced Distributor Products. All rights reserved.
2140 Lake Park Blvd, Richardson, TX 75080
www.adpnow.com
Installation Instructions
Refrigerant Piping .............................................................. 10
Metering Device ................................................................ 10
Refrigerant Line Installation ............................................... 11
Refrigerant Charging Instructions ...................................... 11
Filters ................................................................................. 12
Electrical Requirements .................................................... 12
Electrical Connections ....................................................... 12
Air Handler Checks ........................................................... 13
Air Handler Maintenance ................................................... 14
Assistance or Service ........................................................ 14
Warranty ............................................................................ 15
CAUTION: Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. Caution may also
be used to alert against unsafe practices.
NOTICE: Indicates a statement of company policy as the message
relates directly or indirectly to the safety of personnel or protection of
property.
IMPORTANT: More detailed information concerning the statement of
company policy as the message relates directly or indirectly to the
safety of personnel or protection of property.
All safety messages will tell you what the potential hazard is, tell you how
to reduce the chance of injury, and tell you what can happen if the
instructions are not followed.
IM-SMA-0673615-05
November 2024
PAGE

Advertisement

loading
Need help?

Need help?

Do you have a question about the CP18 and is the answer not in the manual?

Questions and answers

Summary of Contents for Adp CP18

  • Page 1 Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice and without obligation on our part. Please contact your ADP representative or distributor to verify details. © by Advanced Distributor Products. All rights reserved.
  • Page 2 AIR HANDLER SAFETY IMPORTANT IMPORTANT This unit is a PARTIAL UNIT AIR CONDITIONER, complying Improper installation, adjustment, alteration, service or mainte- with PARTIAL UNIT requirements of this Standard, and must nance can cause property damage, personal injury or loss of only be connected to other units that have been confirmed as life.
  • Page 3 WIRING DIAGRAM Part Number: 67811300 | WIRING DIAGRAM, PSC, NO ELECTRIC HEAT Part Number: 67824300 | WIRING DIAGRAM, PSC, ELECTRIC HEAT...
  • Page 4 WIRING DIAGRAM Part Number: 67812900 | WIRING DIAGRAM, ECM, NO ELECTRIC HEAT Part Number: 67844000 | WIRING DIAGRAM, ECM, ELECTRIC HEAT...
  • Page 5 LOW VOLTAGE THERMOSTAT CONNECTIONS Thermostat Connections: 2-speed Motor NOTE: NEC CLASS 2 WIRING NOTE: When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. NEC CLASS 2 wiring Low Voltage Thermostat Connections – 5-speed ECM Constant Torque Motor For 2 stage outdoor units: •...
  • Page 6 ELECTRICAL DATA 2-speed PSC Motor Unit Size Heating Capacity Minimum Maximum Blower Total Current Circuit Circuit (All have electric Ampacity Breaker Size Current (A) BTUH heat) Per Stage (A) 240 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 1.25 1.25 1.25 1.25...
  • Page 7 BLOWER PERFORMANCE DATA 2-speed PSC Motor: • All data is given while air handler is operating with a dry coil and without air filter installed. • Speeds marked *bold with asterisk are the factory speed settings for both heating and cooling. •...
  • Page 8 See the below table for individual weights per model. Model Weight (lb.) CP18, 23 CE18, 23 FIGURE 2 CP19, 24, 29 CE19, 24, 29 CP25, 30...
  • Page 9 ¾″ male pipe thread PVC fittings be used at the condensate pan. Hand tighten only! ADP recommends thread sealant to be used on the PVC connector at the drain If line makes a second trap, or has an extended run before pan connection.
  • Page 10 REFRIGERANT PIPING Refrigerant connections are 3/8″ ODF Liquid and 3/4″ ODF Suction. Refer to outdoor unit manufacturer’s recommendation on line sizing. During brazing of refrigerant lines place a wet rag around suction line to protect cabinet or ceiling from overheating. Maintain a minimum of 1.5″...
  • Page 11 • ADP recommends installing a filter drier and sight glass in the Do not remove the caps from the lines or system liquid line. While brazing, purge the system with Nitrogen to connection points unit connections are ready to be prevent contamination.
  • Page 12 FILTERS Filters are not provided with unit, and must be supplied and installed in the return air system by the installer. A field installed filter grille is recommended for easy and convenient access to the filters for periodic inspection and cleaning. Filters must have adequate face area for the rated air quantity of the unit.
  • Page 13 AIR HANDLER CHECKS Check Blower Operation WARNING 1. Set thermostat to FAN ON. 2. The indoor blower should come on. Electrical Shock Hazard Check Electric Heater (if used) Disconnect all power supplies before servicing. Replace all parts and panels before operating. 1.
  • Page 14 AIR HANDLER MAINTENANCE At the beginning of each heating season the unit should be serviced by a qualified installer or servicing agency. ASSISTANCE OR SERVICE If you need further assistance, you may contact us at the address below with any questions or concerns. Please include a daytime phone number in your correspondence.
  • Page 15 ADP AIR HANDLER LIMITED WARRANTY Term of Warranty Equipment Information Advanced Distributor Products (ADP) warrants that products Please complete information below and retain this warranty for records and future reference. sold shall be of merchantable quality, free of defects in material...
  • Page 16 2140 Lake Park Blvd, Richardson, TX 75080 www.adpnow.com...
  • Page 17 L’amélioration des produits est un processus continu chez Advanced Distributor Products. Par conséquent, les spécifications du produit peuvent être modifiées sans préavis et sans obligation de notre part. Veuillez contacter votre représentant ou distributeur ADP pour vérifier les détails. © par Advanced Distributor Products. Tous droits réservés.
  • Page 18 SÉCURITÉ DU VENTILO-CONVECTEUR IMPORTANT IMPORTANT Cette unité est un CLIMATISEUR À UNITÉ PARTIELLE, Une installation, un réglage, une modification, une conforme aux exigences de la présente norme en matière maintenance et/ou un entretien incorrects peuvent entraîner d’UNITÉ PARTIELLE, et ne doit être connectée qu’à d’autres des dommages matériels ou des blessures graves, voire unités qui ont été...
  • Page 19 SCHÉMA DE CÂBLAGE Réf. Pièce : 67811300 | SCHÉMA DE CÂBLAGE, PSC, PAS DE CHAUFFAGE ÉLECTRIQUE Réf. Pièce : 67824300 | SCHÉMA DE CÂBLAGE, PSC, CHAUFFAGE ÉLECTRIQUE...
  • Page 20 SCHÉMA DE CÂBLAGE Réf. Pièce : 67812900 | SCHÉMA DE CÂBLAGE, ECM, PAS DE CHAUFFAGE ÉLECTRIQUE Réf. Pièce : 67824400 | SCHÉMA DE CÂBLAGE, ECM, CHAUFFAGE ÉLECTRIQUE...
  • Page 21 CONNEXIONS DU THERMOSTAT BASSE TENSION Connexions du thermostat : moteur à 2 vitesses REMARQUE : CÂBLAGE NEC CLASSE 2 REMARQUE : Quand le thermostat de pièce demande un chauffage de deuxième stage, le fonctionnement de premier stage (thermopompe) doit être verrouillé. Câblage NEC CLASSE 2 Connexions du thermostat basse tension –...
  • Page 22 DONNÉES ÉLECTRIQUES Moteur PSC à 2 vitesses Capacité de Taille de l'unité chauffage Taille Courant Ampérage Courant total maximale du ventilateur minimal du (Tous ont un disjoncteur circuit (A) chauffage BTUH par étape (A) électrique) 240 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 208 V 240 V 1,25 1,25 1,25 1,25...
  • Page 23 RENDEMENT DU VENTILATEUR Moteur PSC à 2 vitesses : • Toutes les données sont données quand le ventilo- convecteur fonctionne avec un serpentin sec et sans filtre à air installé. • Les vitesses marquées *d’un astérisque sont les réglages usine pour le chauffage et la climatisation. •...
  • Page 24 Voir le tableau ci-dessous pour les poids individuels par modèle. Modèle Poids (lb) CP18, 23 CE18, 23 CP19, 24, 29 CE19, 24, 29 FIGURE 2 CP25, 30 CE25, 30 Le ventilo-convecteur à...
  • Page 25 Serrer à la main uniquement! ADP recommande d’utiliser un agent d’étanchéité pour filetage sur le connecteur en PVC au niveau du raccord de Si la conduite fait un deuxième purgeur ou a un tronçon la cuvette de drainage.
  • Page 26 CONDUITE DE RÉFRIGÉRANT Les connexions de réfrigérant sont 3/8 po ODF Liquid et 3/4 po ODF Suction. Se reporter aux recommandations du fabricant de l’unité extérieure sur le dimensionnement de la conduite. Pendant le brasage des conduites de réfrigérant, placer un chiffon humide autour de la conduite d’aspiration pour protéger l’enceinte ou le plafond de la surchauffe.
  • Page 27 • ADP recommande d’installer un filtre déshydrateur et une vitre Ne pas retirer les capuchons des conduites ou des points dans la conduite de liquide. Pendant le brasage, purger le de connexion du système.
  • Page 28 FILTRES Les filtres ne sont pas fournis avec l’unité et doivent être fournis et installés dans le système de retour d’air par l’installateur. Une grille de filtration installée sur place est recommandée pour un accès facile et pratique aux filtres pour une inspection et un nettoyage périodiques.
  • Page 29 VÉRIFICATIONS DU MANUTENTEUR D’AIR Vérifier fonct. du ventilateur AVERTISSEMENT 1. Mettre le thermostat sur VENTILATEUR. 2. Le ventilateur intérieur doit s'allumer. Risque d'électrocution! Vérifier le réchauffeur électrique Déconnecter toutes les sources d’alimentation avant de (le cas échéant) procéder à l’entretien. Remettre toutes les pièces et panneaux en place avant de 1.
  • Page 30 ENTRETIEN DU VENTILO-CONVECTEUR Au début de chaque saison de chauffage, l’unité doit être entretenue par un installateur ou une société d’entretien qualifié. ASSISTANCE OU SERVICE Si vous avez besoin d’aide, vous pouvez nous contacter à l’adresse ci-dessous pour toute question ou préoccupation. Veuillez indiquer un numéro de téléphone de jour dans votre correspondance.
  • Page 31 GARANTIE LIMITÉE SUR LE VENTILO-CONVECTEUR ADP Durée de la garantie Information sur l’équipement Advanced Distributor Products (ADP) garantit que ses produits Veuillez écrire les renseignements demandés ci-dessous et conserver la présente garantie dans vos dossiers, pour vendus seront de qualité marchande, exempts de défauts de consultation future.
  • Page 32 2140 Lake Park Blvd, Richardson, TX 75080, États-Unis www.adpnow.com...