  • Page 1 LT-500 PS II USER MANUAL Version:1.0...
  • Page 3: Table Of Contents

    Table of content 1.Open-Package guidelines............... 1.1Package....................1 2.Safety instructions..................1 3.Operating determination.................2 4.Rigging the fixture...................3 4.1 Mounting.....................3 4.2Installing the Clamps................3 4.3 Power supply connection and cut off...........4 4.4 Power Connection................4 4.5 DMX-512 connection/connection between fixtures......4 Description of the device............
  • Page 4 Congratulations on choosing our products! Please carefully read this instruction manual in its entirety and keep it well for using reference. This manual contained about the installation and the relative using information of this products. Plese refere this manual's relative instruction when using this equipment.
  • Page 5: Open-Package Guidelines

    1.Open-Package guidelines This equipment is made of new style,high intensity plastic.It fully shows the modem times light charac teris- tic with teristic with beauty struture. And it is made accord to CE standard. Fully agree with the internation standard of DMX 512 agreement.
  • Page 6: Operating Determination

    Minimum distance of illuminated objects 0.8m The projector needs to be positioned so that the objects hit by the beam of light are at least 0.80 metres from the lens of the projector. Maximum ambient temperature ° C t 45 Do not operate the fixture if the ambient temperatuer(Ta) exceeds 45°...
  • Page 7: Rigging The Fixture

    The minimum distance between light output and the illuminated surface must be more than 0.2 meters. Make sure that the area below the installation place is blocked when rigging,derigging or servicing the fixture. Always fix the fixture with an appropriate safety rope, Fix the safety rope at the correct holes only. Operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastend.
  • Page 8: Power Supply Connection And Cut Off

    The projector should be installed outside areas where persons m ay walk by or be seated. Important!Overhead rigging requires extensive expering CE,including (but not limited to) calculating working load limits, installation material being used, and periodic safety inspection of all installation ma- terial and the projector.
  • Page 9 DMX512 Max loop 2 fixture at 110V, Max loop 4 fixture at 240V. Caution At the last fixture,the DMX-cable has to be terminated with a terminatou. solder a 120 resistor between signal(-) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. DMX output DMX iutput DMX output...
  • Page 10: Description Of The Device

    5.Description of the device Power-In 3-pin XLR male 3.3-pin XLR female Power-Out ENTER button DOWN button UP button MODE button Display 10.Respirator ETHERNET 6.Dimension 1 00mm - 6 -...
  • Page 11: Display Control

    7.Display control 7.1 Navigation in the Menu Using the buttons, and this can be simply and easily set the address code and function code. If you view or modify the lighting feature set, then press ENTER button, the display will enter the menu interface.
  • Page 12 Curve 1 Curve 2 Dimmer Curve Curve 3 Curve 4 Dimmer Speed Fast* / Smooth Gamma 1.0 RGB Gamma Gamma 1.5 Gamma 2.2 RGB1 Reverse ON / OFF* RGB2 Reverse ON / OFF* Strobe Reverse ON / OFF* RGB Mode 16* / 32 DMX* Smart Glass...
  • Page 13: Dmx Protocol

    8.DMX protocol Mode1 Mode2 Mode3 Mode4 Mode5 RGB16 RGB32 Strobe Fade Type Function Dmx Value Layer 1 Red 0→100% 0-255 Layer 1 Red fine 0→100% 0-255 Layer 1 Green 0→100% 0-255 Layer 1 Green fine 0→100% 0-255 Layer 1 Blue 0→100% 0-255 Layer 1 Blue fine...
  • Page 14 Layer 2 Background Red Background Red Linear 0 – 104-107 Layer 2 Background Red Fine Background Red Fine 108-207 Layer 2 Background Green Background Green Linear 0 – 208-212 Layer 2 Background Green Fine Background Green Fine 213-225 Layer 2 Background Blue Background Blue Linear 0 –...
  • Page 15: Maintance And Cleaning

    9.Maintance and cleaning DANGER:Disconnect from the mains before starting any maintenance work. It is absolutely essential that the fixture is kept clean and that dust,dirt and smoke fluid residues must not buildup on or within the fixture. Otherwise, the fixtures light-output will be significantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably through out its life.
  • Page 16: Electric Equipment Specification

    10.Electric equipment specification 10.1 Electrical paramters SOURCE: RGB 672 LED-5050,W 112LED-3535 Max POWER: 420W VOLTAGE: AC100-240V 50/60HZ Color temperature:8000K(W) 10.2 Weight and dimensions Dimensions: 1000X160X160mm NET WEIGHT:10Kg 10.3 Channel Characteristics 10/14/32/40/Pi xel 48CH/ St robe 16CH/ Pi xel(32)96CH/ DMX 1.Ch annel: -512.
  • Page 17: Electronic Drawing

    11.Electronic drawing VCC+ µ ç × Ó Î í » ¯ µ ç × Ó Î í » ¯ T1 T2 - - - - - NTC TX 500PS II LED DRIVER CONTROL AC220V DC24V 1BLACK 1BLACK AC220V AC220V 2Yellow 2Yellow 3RED 3RED...