  • Page 1 USER MANUAL...
  • Page 3: Table Of Contents

    Table of content 1.Open-Package guidelines................1  1.1Package....................1 2.Safety instructions..................1 3.Operating determination................3 4.Rigging the fixture..................4 4.1 Mounting....................4 4.2Installing the Clamps................4 4.3 Power supply connection and cut off.............6 4.4 POWER Connection................6 4.5 DMX-512 connection/connection between fixtures......6 Description of the device................7 Display control..................8 Navigation in the Menu................8 Display OPeration................8 Menu Maps ..................9 7.DMX protocol..................10...
  • Page 4 Congratulations on choosing our products! Please carefully read this instruction manual in its entirety and keep it well for using reference. This manual contained about the installation and the relative using information of this products. Plese refere this manual's relative instruction when using this equipment.
  • Page 5: Open-Package Guidelines

    1.Open-Package guidelines This equipment is made of new style,high intensity plastic.It fully shows the modem times light charac teris- tic with teristic with beauty struture. And it is made accord to CE standard. Fully agree with the internation standard of DMX 512 agreement.
  • Page 6 Never let the power-cord come into contact with other cables! Handle the power cord and all connections with particular caution! Make sure that the available voltage is not higher than stated on the rearpanel. Always plug in the power plug least. Make suer that the power-switch is set to off-position before you con ections with themains with particular caution! Make sure that the power-cord is never crimped or damaged by sharp edges.Check the decice and the p- ower-cord from time to time.
  • Page 7: Operating Determination

    lines of the projectors from indirect contact and/orshorting to earth by using appropriately sized residual current devices. Disposing This product is supplied in compliance with European Directive 2012/19/EU-Waste Electrical and Electronic Equipment (WEEE). To preserve the environment please dispose/recycde this product at the end of its life according to the local regulation.
  • Page 8: Rigging The Fixture

    4.Rigging the fixture 4.1 Mounting Pay attention to the regulations of CE. Installation by qualified staff to complete. For the various mounting positions of the FIXTURE(standing on the floor, sideways or hanging different accessories kits are available. Through this a safe and firm installation is assured. You’ll find special connectors on the bottom side of the system which are put to use here.
  • Page 9 The projector can be placed directly on the stage floor or rigged in any orientation on atruss without alte- ring its operation characteristics. For overhead use,always install a safety-rope that can hold at least 10 times the weight of the fixture.You must only use safety-ropes with screw on carabines.Pull the safety-rope through the two apertures on the bottom of the base and over the trussing system etc.
  • Page 10: Power Supply Connection And Cut Off

    4.3 Power supply connection and cut off Connect the light source to the main power source with the plug of the power cord, or cut off the power supply: Connection: according to procedures, the power plug and socket is inserted into the groove one one alignment,rotation.
  • Page 11: Description Of The Device

    DMX Terminator Diagram -For installations where the DMX cable has to run a long distance or is In an electrically noisy environment it is recommended to use a DMX terminator. This help in preventing corruption of the signal by electrical noise. The DMX terminato r is simply an XLR plug witha Ω...
  • Page 12: Display Control

    6.Display control Navigation in the Menu *Address and functions can be set simply and conveniently by pressing the button. Press any button to view or modify the function Settings, and the display will enter the menu operation interface. There are corresponding submenus under each main level for unction operation. Every menu represents the specific function of devices;...
  • Page 13: Menu Maps

    6.3 Menu Maps Address code 1-512 Self running 1 Running mode Self running 2 Voice control Local number 1-255 Channel mode 18 channel Open Level reversal Close Open Vertical reversal Close System setting Open XY exchange Close Open XY error correct Close Kept Without signal...
  • Page 14: Dmx Protocol

    7.DMX protocol Mode1 Fade Type Dmx Value Function PAN0~540° 0-255 TILT TILT0~240° 0-255 Dimming Dimming from dark to light 0-255 Light up Synchronous strobe 4-100 Split strobe 101-150 Strobe Quickly strobe 151-200 Randomly strobe 201-250 Light up ( No delay dimming ) 251-255 white light white light+color1...
  • Page 15 Mode1 Fade Type Dmx Value Function gobo3 8-11 gobo4 12-15 gobo5 16-19 gobo6 20-23 gobo7 24-27 gobo8 28-31 gobo9 31-35 gobo10 36-39 gobo11 40-43 gobo12 44-47 gobo13 48-51 gobo14 52-55 gobo15 56-59 gobo16 60-63 gobo17 64-67 gobo18 68-71 gobo1shake 72-78 gobo2shake 79-85 Gobo...
  • Page 16: Maintenance And Cleaning

    Mode1 Fade Type Dmx Value Function prism1 rotate360° 0-127 Prism1self- prism1anticlockwiseself-rotation( slow to fast ) 128-191 rotation(8) prism1clockwiseself-rotation(slow to fast) 192-255 prism2 shift out 0-127 Prism2(48) prism2 cut-over 128-255 prism2 rotate360° 0-127 Prism2self- prism2anticlockwiseself-rotation(slow to fast) 128-191 rotation(48) prism2clockwiseself-rotation( slow to fast ) 192-255 Zoom 0 to 100% linear focus...
  • Page 17: Electric Equipment Specification

    through out its life. A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circum stances should alcohol or solvents be used! The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues,reduc- ing the light-output very quickly.The cooling-fans should be cleaned monthly.
  • Page 18: Light Table

    9.5 light table 102453 25614 11384 Illuminance(Lux) 6430 2° Projection distance(m) Φ0.15 Φ0.3 Φ0.45 Φ0.6 Flare diameter(m) 9.6 Gobo wheel - 14 -...
  • Page 19: Color Wheel

    9.7 Color wheel 11 light orange 10 CTO 1red 2green 9Light Red 3blue 8Orange 7 Light blue 4yellow 5Rose red 6 Light Green - 15 -...
  • Page 20: Electronic Drawing

    10.Electronic drawing 24 Prism Titl Focus 24 Prism Roating motor motor motor motor motor Focus sensor Fix Gobo wheel sensor Color wheel sensor Displayer Titl Board sensor sensor 8 Prism Pan. Frost Colorful Color Titl. 8 Prism Roating motor Gobo motor wheel motor...
  • Page 22 ht tp: //www.jol lyl ight ing. com Guangzhou hongcai stage equipment Co.,Ltd Tel:+862084558833 Fax:+862084559699 Email:info@jollylighting.com P.C:511450 Add:Building2,No.32,Changsha Street,Shachong Village,shiji Tow.Panyu District,Guangzhou,China...

This manual is also suitable for: