Table of Contents

Advertisement

Quick Links

Counting Configuration Guide
BRICKSTREAM®
3D Gen 2
Release 6.3 – June 2022
6/29/2022
Names and marks appearing on the products herein are either
registered trademarks or trademarks of FLIR Systems, Inc. and/or its
subsidiaries.
© 2018-2022 FLIR Integrated Imaging Solutions Inc. All rights
reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLIR BRICKSTREAM 3D Gen 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Teledyne FLIR BRICKSTREAM 3D Gen 2

  • Page 1 Counting Configuration Guide BRICKSTREAM® 3D Gen 2 Release 6.3 – June 2022 6/29/2022 Names and marks appearing on the products herein are either registered trademarks or trademarks of FLIR Systems, Inc. and/or its subsidiaries. © 2018-2022 FLIR Integrated Imaging Solutions Inc. All rights reserved.
  • Page 2 To view the licenses of open source packages used in this product please see KB11065 What open source packages do people counting products use? 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 3: Table Of Contents

    Step 10 of 10—Networking Configuring the Basic Settings Setting up a LAN or Wi-Fi Connection Using a LAN Using Wi-Fi 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 4 Setting Tailgating Delivery Options Setting Path Linking Options Importing and Exporting Configurations Exporting a Configuration File Importing a Configuration File 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 5 Multiple Count Zone Support Tailgating Detection Naming Reporting Zones Adding New Counting Zones Refining the Zone Configuration Zone Parameters and Alerts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 6 Relocation Solution Tracking Configuration Solution Resolving Inoperable 3D Gen 2 Issues Power Issue Connectivity Issue Software/Firmware Issue Troubleshooting Counting Issues 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 7 Tracking Parameters - Tracking Tab Tracking Parameters - Stereo Tab Tracking Parameters - Sensor Tab Tracking Parameters - Quality Tab 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 8: Introduction

    Information about how to upgrade the firmware on the sensor via TFTP or for a 3D Gen 2 Sensor HTTP. Troubleshooting Troubleshooting and corrective actions. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 9: About The Brickstream 3D Gen 2 Sensor

    Provides optional Wi-Fi and BLE support with a USB Wi-Fi BLE dongle (2510 model only - dongle sold separately) 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 10: Hardware Components

    The web interface provides configuration capabilities for the sensor. Note: The sensor's firmware version is in the footer of the sensor web interface. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 11: Prerequisites For Configuration

    Additional features can be activated through separate licenses, including: Employee filtering (2510 model only) Wi-Fi network connection (2510 model only) Tailgating detection Occupancy management 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 12 To view current licenses or to add a new license key go to the License Info page under the System menu. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 13: Data Quality

    Unpredictable Tall Moving Objects Over counting Uneven surface Under counting Heavy rain Under counting Dirty or scratched lens* Under counting 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 14 Transparent or translucent objects Unpredictable Noisy data Unpredictable *Depending on the severity, this may appear as a calibration failure and be automatically detected. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 15: Setting Up The Sensor

    IP address to a client network IP address. Note: The sensor's firmware version is in the footer of the sensor web interface. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 16: Navigation

    Establishing network connectivity, time synchronization, Device Manager Settings connectivity, configuration of tracks, destinations for logs, password protection, and privacy options, accessible from the Settings submenu items 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 17 There is a selection table to show or hide configured counting, queuing, service and detection zones. This selection is displayed in a video pane as well as the graph. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 18: Functions Of The Web Interface Buttons

    There is also a table with sensor identification. Functions of the Web Interface Buttons The web interface offers the following methods to store changes to the sensor’s configuration file. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 19: Preconfiguration Process

    Note: No other network connections may be active during this process. 4. Click the Start icon and select Control Panel from the desktop of your PC. The Control Panel opens. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 20 7. Click Wireless Network Connection and then click Disable this network device, if applicable. 8. Right-click on Local Area Connection and choose Properties. The Local Area Connection Properties window opens. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 21 If these settings are not configured to be obtained automatically, record the initial values here: TCP/IP Setting Initial Value on PC IP address Subnet mask Default gateway 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 22 18. Plug a CAT5e Ethernet cable from the Hub/Switch or LAN or IN port of the PoE injector to the Ethernet port in your PC. Note: The port labels may vary depending on the manufacturer of the PoE injector. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 23: Using The Configuration Wizard

    The default (and recommended) selection is Latest. 4. Click Save & Next. Note: This information is also on the Settings->Device Identification page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 24: Step 2 Of 10-Date And Time

    4. In the Port Number field, enter the port number from which the sensor should attempt to get a time synchronization. The default port depends on the protocol selected: Protocol Default Port Brickstream 2010 Daytime SNTP 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 25 6. Alternatively, you can set the date and time manually and click Set Time. 7. Click Save & Next. Note: This information is also on the Settings->Basic Settings page, Date and Time tab. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 26: Step 3 Of 10-User Management

    5. Click Save & Next. You are then prompted to enter the name and password for authentication. Note: This information is also on the Settings->Basic Settings page, Web Server tab. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 27: Step 4 Of 10-Privacy Settings

    2. AVI Capture is enabled by default. To disable, click the AVI Capture switch to OFF. 3. Click Save & Next. Note: This information is also on the Settings->Basic Settings Privacy page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 28: Step 5 Of 10-Device Manager

    A success or failure message is displayed at the top of the page depending on the outcome. 9. Click Save & Next. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 29 Brickstream® 3D Gen 2 Version 6.3 Note: This information is also on the Settings->Basic Settings page, Device Manager tab. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 30: Step 6 Of 10-Http Proxy

    6. To confirm that the settings are correct, click Test Settings. 7. Click Save & Next. Note: This information is also on the Settings->Basic Settings page, HTTP Proxy tab. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 31: Step 7 Of 10-Calibration (Part 1)

    2. Is the camera installed indoors? 3. Do you want to calibrate the camera? If you select No, the wizard skips step 8. 4. Click Save & Next. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 32: Step 8 Of 10-Calibration (Part 2)

    X and Y rotation should be within 10 degrees of visual angle estimate. 4. Click Save & Next. Note: This information is also on the Calibration page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 33: Step 9 Of 10-Data Delivery

    In the SNI Host Name field, enter the Server Name Indication (SNI) hostname or IP address for the host. 9. Click Test Settings to confirm entries. 10. Click Save & Next. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 34 Brickstream® 3D Gen 2 Version 6.3 Note: This information is also on the Data Delivery->Batch page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 35: Step 10 Of 10-Networking

    Note: If you change the IP address on a sensor and save your changes, you lose connectivity to the sensor for several seconds while it is being enabled with the new IP address. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 36: Configuring The Basic Settings

    Setting up a LAN connection can be done on the Basic Settings page or in the Configuration Wizard. Setting up Wi-Fi can only be done on the Basic Settings page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 37: Using A Lan

    4. If your network does not use DHCP, click the switch to OFF and enter the following information: Sensor IP Address Network Mask Default Gateway DNS Server 5. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 38: Using Wi-Fi

    IP addresses for sensors at this location before choosing to use DHCP with the sensors. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 39: Setting The Web Server Information

    An Operator user is for daily functions and maintenance of the sensor and has access to: Home page System—Histograms System—Reboot Calibration All zone pages Data Delivery—AVI capture Employee Filtering 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 40 ! # $ / % ' ( ) [ ] { } + - . , | = < > _ * ; ~ ? ^ 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 41 ! # $ / % ' ( ) [ ] { } + - . , | = < > _ * ; ~ ? ^ c. In the Re-Enter Password field, re-enter the password. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 42 To delete an operator you must be signed in as administrator. On the Basic Settings Web Server tab, clear the operator username field and click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 43: Setting The Date And Time

    Automatic Time Synchronization 1. On the Settings>Basic Settings page, click the Date & Time tab. 2. From the Time Server Protocol drop-down, select an appropriate protocol. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 44 IP address and port specified on the Date and Time Info page. A success or failure message is displayed at the top of the page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 45: Manual Time Setup

    6. In the API Token field, enter the API token. An API token is a cryptic string of up to 255 characters, used to authenticate access to the HTTPS server. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 46: Setting The Device Manager Server

    7. In the Connect Frequency field, enter the frequency (in milliseconds) that the sensor checks the Device Manager Server for connection requests. The default value is 10000. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 47: Configuring Proxy Settings

    If you are using the Brickstream Device Manager to store metric data, you should set the Site ID. The Device Manager attempts to match the Site ID to a Site ID in the Operational Database in order to auto- 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 48 If a time is selected, the LED lights are on during the reboot to verify the startup sequence and then turn off once the selected time has passed. 5. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 49: Setting Data Delivery Options

    The sensor can deliver batch data to up to two servers. Set the batch data delivery options as follows. 1. Open the web interface to the Data Delivery> Batch page. 2. Click the Batch 1 switch to ON. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 50 HTTP POST. 6. From the Aggregation Level list select how often to aggregate the count report in minutes (1, 5, 15, 30, or 60). 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 51: Setting Email Delivery Options

    1. Open the web interface to the  Data Delivery> Email page. 2. Click the Email Delivery switch to ON. The fields become active. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 52 5. In the Sender Email Address field, enter the email address of the person that is sending the email. 6. In the Recipient Email Address field, enter the email address of the person to receive the email. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 53 Note: If you receive an error message, see Troubleshooting. 12. If possible, check the recipient's email to ensure that the test email arrives. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 54: Setting Ftp Delivery Options

    1. Open the web interface to the Data Delivery> FTP page. 2. Click the FTP Delivery switch to ON. The fields become active. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 55 Brickstream® 3D Gen 2 Version 6.3 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 56 For the following examples, assume the site name is set to Grocery1 and the site ID is set to 987. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 57 16. If you are using a SSL Virtual Host and Server Name Identification, in the SNI Host Name field, enter the host name. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 58: Setting Real Time Data Delivery Options

    1. Open the web interface to the  Data Delivery> Real Time page. 2. Click the Real Time Delivery 1 switch to ON. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 59: Setting Alert Delivery Options

    6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 60 Sends an HTTP GET to the URL address specified in the Destination field. The specific HTTP page request is defined on the Counting page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 61 11. Click Save. To configure the alert message that is sent from the sensor, see Configuring Alerts for Counting Lines Zones. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 62: Alert Protocol Examples

    17. If you count the number of characters (including spaces) in the text: Someone Walked In, you will see it is 17 characters (which equates to 17 bytes). Exit Counts VLI custom content for exit counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 63: Total Count Values

    The number is not the daily count total. The following examples include the total count values for the VLI option. Enter counts VLI custom content for enter counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 64: Http Post Custom Content Display

    The following is an example of the HTTP Post custom content display for both enter and exit counts using Wireshark, an open-source packet analyzer. Enter counts HTTP post custom content for enter counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 65: Total Count Values For The Http Post Option

    The number is not the daily count total. The following examples include the total count values for the HTTP Post option. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 66: Http Post Page

    In addition, you can also define the page where the HTTP Post should be sent for alerts. In the following examples, the Enter URL field was changed from '/' to 'parseCounts.html'. Enter counts HTTP post custom content for enter counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 67: Tcp Custom Content Display

    The following is an example of the TCP custom content display for both enter and exit counts using Wireshark, an open-source packet analyzer. Enter counts TCP custom content for enter counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 68: Tcp Option

    The number is not the daily count total. The following examples include the total count values for the TCP option. Enter counts TCP custom content for enter counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 69: Http Custom Content Display

    The following is an example of the HTTP custom content display for both enter and exit counts using Wireshark, an open-source packet analyzer. Enter Counts HTTP custom content for enter counts 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 70: Deliver Counts Option

    If you enabled the Deliver Counts option for alerts, then the details are parameterized and encoded in the GET command as seen in the following examples. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 71: Setting Traffic Map Delivery

    1. Open the web interface to the Data Delivery > Traffic Maps Settings page. 2. Click the Traffic Maps switch to ON. The fields become active. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 72 15 to 20 minutes. After a successful send, or after three failed attempts, the sensor deletes that batch of data. Once deleted the data cannot be recovered. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 73: Setting Available Sensor Data Options

    2. From the Delivery Method drop-down, select a format for data delivery. The options depend on which data delivery options are enabled on the Data Delivery page: Email 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 74: Setting Wi-Fi Options

    5. If the sensor needs to send data feeds to a specific URL address in the HTTP POST, in the Destination URL/directory field enter the URL address. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 75: Setting Track Data Delivery Options

    Note: For details about track data including the data schema and format, see the Track Data Technical Note. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 76 The data is contained within an HTTP POST — the same HTTP structure as a standard HTTP post to the server. The application must return an HTTP acknowledgment. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 77: Setting Tailgating Delivery Options

    Refining the Zone Configuration). 1. Open the web interface to the  Data Delivery> Tailgating page. 2. Click the Enable Delivery switch to ON. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 78 Select the number of images (1 to 5) to be delivered in the alert. 10. Click Test Settings to confirm entries. 11. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 79: Setting Path Linking Options

    Note: Path linking is not supported on sensors that use a DHCP server for their IP addresses. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 80: Importing And Exporting Configurations

    Importing a Configuration File Complete the following steps to import a configuration file into a sensor. 1. Open the web interface to the System>Import/Export Config page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 81 5. Double-click the configuration file. 6. Click Import Config. A message appears at the top of the page stating that the configuration file was successfully imported and saved. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 82: Calibrating And Configuring The Tracking System

    Height—Displays the height of objects as they are tracked through the sensor field of view. Video Pane 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 83 The Height Map accumulates historical imagery. If you wish to purge the historical imagery, click Clear Maps. Rebooting or changing height, tilt, or zoom settings also clears map data. Map Pane 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 84: Calibrating A Sensor

    Complete the following steps to perform calibration. 1. Open the web interface. 2. Click Calibration. The Calibration page opens. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 85 Select whether to use digital zoom of 20%, 40%, 60%, 80%, or 100% and click Save. 5. In the Video Pane, configure the calibration box. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 86 Calculated height should be within 20% of visual height estimate. X and Y rotation should be within 10 degrees of visual angle estimate. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 87 Select whether to use digital zoom of 20%, 40%, 60%, 80%, or 100%. Note that Zoom Level saving a new zoom level requires a recalibration of the sensor. Zones may need to be reconfigured. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 88 A good calibration shows a high percentage of yellow in the map pane. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 89: Verifying The Calibration For Counting Or Low Volume Tracking

    The shaded areas may change to red or light blue looking out from the center of the floor area. Use the following samples to assist you in verifying the calibration: 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 90 A majority of the floor area is shaded green. Calibration Increase X Axis The top of the floor area is shaded red, the Value bottom is shaded blue. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 91 The left area of the floor is shaded red, the Value right is shaded blue. Increase the Most of the floor is shaded red. Sensor height 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 92: Using The Sensor In Outdoor Or High Mount Environments

    The following is an example of intraday changes in calibration height, where the height ranges between 1690 cm and 1640 cm. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 93: Region Of Interest (Roi) Processing

    6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 94: Wide Mode For High Mount Installations

    Lens Coverage section or consult your coverage guide spreadsheet. Note: Digital zoom is not used with wide mode. Digital zoom is an alternative method to maintain accuracy for high mount installations. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 95: Setting Object Filtering Options

    The Brickstream sensor has three methods of filtering out unwanted objects to prevent them from being counted. Defined Tracking Range—prevents objects or parts of objects from being tracked based on minimum and maximum height settings. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 96: Defined Tracking Range

    The child is excluded from counting based on the height filter. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 97: To Enable Cart Filtering

    The sensor compares the average mass height with the Maximum Average Height threshold. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 98: Setting Background Adaptation

    Complete the following steps to set the background adaptation. 1. Access the Calibration page. 2. Under Background Adaptation Delay, if the site is a counting only site, select Counting. If the 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 99: Ensuring The Tracking System Is Functioning Properly

    Note: If the circles seem too close together, increase the 3D Zoom value. If you are not seeing the full length of tracks, decrease the 3D Zoom value. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 100 If you notice that the color changes happen unevenly from the left to the right of the image space, check the X rotation on the Calibration page. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 101: Configuring Counting Lines

    Lines should be drawn on the floor based on a customer’s foot position. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 102: Total Counts And Session Counts

    (Start Track Max Distance). Once tracks pass this set of checks, they must also stay within a certain distance of one another (Track Max Distance) through the sensor's field of view. If tracks 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 103: Child Counting

    When the Child Counting feature is turned on, the zone only counts tracks that have heights below the Height Filter set on the Calibration page. Any track with a height taller than the Height Filter is excluded from the enter/exit counts. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 104: Employee Filtering (2510 Model Only)

    For Exit counts, the Filter Zone defines an area in which tracks must end in order to be counted as an exit. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 105: Multiple Count Zone Support

    “Front Door Entrances” and the zone counting entrances through the back door “Back Door Entrances.” 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 106: Adding New Counting Zones

    1. Access the 3D Gen 2 web interface, and click Zones >Counting to view the current counting configuration. 2. Click the Add button. The Add New Zone dialog opens. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 107: Refining The Zone Configuration

    1. Select the associated zone, and then click Edit. The Edit Zone dialog opens. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 108 Exits. See note below. Governs whether to exclude tracks that are traveling Velocity switch faster than a certain speed 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 109 3. When you have finished your edits, click Save to save the configuration. 4. If you enabled Shopping Units, Velocity, Predicted Distance, or Tailgating, and wish to modify the defaults, click Edit Count Global Parameters. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 110 If the start points of two or more tracks are further Distance apart than this threshold, they are not counted as a shopping unit. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 111: Zone Parameters And Alerts

    Some configuration parameters affect the timing of real-time alerts. Delayed alerts wait for a track to terminate before sending. With employee filtering enabled, the delay is one additional second after the 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 112: Drawing Enter, Exit, And Exclusion Lines

    2. Access the 3D Gen 2 web interface, and click Zones > Counting to view the current counting configuration. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 113 We recommend this setting remain at 90 cm for all applications. Note: Counting lines function best when drawn near the center of the sensor’s field of view. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 114 Multiple lines of the same type whose traffic flows are in opposite or conflicting directions will produce invalid results. See below. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 115 8. Click Save. When working with shapes the following shortcut keys are available: Shortcut Keys Function Select the next shape 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 116 Lock the position of selected shapes Ctrl + H Flip selected shapes horizontally Ctrl + V Flip selected shapes vertically Delete Delete the selected shapes 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 117: Adding Filter Zones To Count Zones

    6. Click and drag each orange handle to reshape the zone to your specifications. Place the filter zone in the entrance corridor and extend it all the way to the exterior side of the store. 7. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 118 Lock the position of selected shapes Ctrl + H Flip selected shapes horizontally Ctrl + V Flip selected shapes vertically Delete Delete the selected shapes 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 119: Verifying Count Line, Filter Placement, And Calibration

    1. Access the Counting Configuration page. Select Traffic Map from the map pane list, and then click Clear Maps. 2. Allow the sensor to run for 4-6 hours depending on traffic volume. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 120 3. Verify that all starts and stops are included in the desired filter zone and that the enter/exit lines have not been drawn too close to the start and stop points. 4. Click Save. The changes are saved. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 121: Enabling Predictive Event Triggering

    1. Create count lines as described in previous sections. 2. Select the zone and click the Edit button. The Edit Zone pop-up appears. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 122 120 cm projection forward in space. When people are moving slowly, this feature applies a bigger projection to predict a 60 to 120 cm projection. 7. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 123: Configuring Alerts For Counting Lines And Zones

    See Alert Protocol Examples for examples of VLI settings. 6. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 124: Deleting Counting Lines

    3. Select the reporting zone to be removed. 4. Click Delete. A confirmation dialog appears. 5. Click Confirm Delete. The zone and all attached lines are deleted. 6. Click Save. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 125: Upgrading Firmware For A 3D Gen 2 Sensor

    5. Click Upgrade to begin the file upload. A green light should blink on the sensor indicating that the new firmware is being uploaded. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 126: Upgrading Sensor Firmware Via Tftp

    Warning! Ensure that the TFTP server is not installed on a machine that is protected by a firewall. 1. Open the TFTP directory of the OEMPack. 2. Run the TFTP executable file. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 127: Upgrading Sensor Firmware

    4. Turn off the Windows Firewall on the computer running the TFTP server (Start > Control Panel > Windows Firewall). 5. Open the sensor's web interface. 6. Click System > Upgrade. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 128 12. After a couple of minutes (or less), you should regain a connection to the sensor web interface. Click the browser refresh button to ensure that the upgrade was successful. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 129 Brickstream® 3D Gen 2 Version 6.3 Note: If there are difficulties upgrading this sensor, see Troubleshooting Firmware Upgrades when Using a TFTP Server 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 130: Troubleshooting

    User ID and/or Password that the sensor attempted to use did not match that of the User ID or Password stored on the SMTP Server. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 131: Error Message #3-Invalid Smtp Server Address

    This message indicates that the email address listed in the From field on the Data Delivery tab of the sensor was either not found, or the account does not have permission to send email messages. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 132: Error Message #5-Sensor Cannot Connect To Smtp Server

    The system was able to access the SMTP Server but the email address listed in the To field was not a valid email address. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 133 Type the recipient email address in the To field. Click Test Email Settings to send a test email. If the email was successfully sent, click Save to save the new configuration. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 134: Troubleshooting Ftp Connections

    Incorrect Server IP Address Failed to connect 64 Incorrect Port Number Failed to connect 530 password not accepted Incorrect Username and/or Password 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 135: Resetting The Sensor

    Note: LED 2 shows a sequence of colors depending on how long you depress the Reset button. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 136 Note: Contact Brickstream Support if you see a different LED combination than what is documented. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 137: Troubleshooting Firmware Upgrades When Using A Tftp Server

    Drivers can be updated using the same method as upgrading firmware described in Upgrading Firmware for a 3D Gen 2 Sensor. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 138: Troubleshooting Low-Ceiling Installations

    2.4 m. 3. Verify that the pink percentage on the Calibration page is still in an appropriate range after making the adjustments. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 139: Resolving Inoperable 3D Gen 2 Issues

    3. Contact PCT-Support@flir.com to receive additional assistance based on these findings. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 140: Software/Firmware Issue

    Release number displayed in the footer of the 3D Gen 2 web interface. Contact PCT-Support@flir.com with this information to receive additional instructions. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 141: Troubleshooting Counting Issues

    180 cm range in the Height Map in the right pane of the Counting Zone Manager page. The following figure shows a desirable height map, indicated by the predominance of yellow and dark yellow. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 142 If no white patches exist, skip to step Good Height Image Bad Height Image 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 143 Surface Validation Diff. setting on the Stereo sub-tab from 1.0 to 0.5. 8. Click Preview. 9. Use the following table to determine your next action: 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 144 Couples setting for the Counting Method on the Calibration Settings page. 13. Save settings and capture a background. 14. If problems still persist, attempt to manually set and visually verify calibration parameters. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 145: Adjustments To Tracking Configuration

    3. If the Calibration page displays in pink pixels, capture a right lens image and a left lens image from the sensor, and send these images along with the Height Image data through an RMA request. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 146: Tracking Parameters

    Save to retain the default values. Preview, Save, Reset, and Load Defaults functions affect values on all tabs. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc.
  • Page 147: Default Values

    6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 148: Tracking Parameters - Basic Tab

    One of three track analytics fields; all three DISTANCE must be met by the track to be included in the count/queue function. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 149 Dependent ROI Top Y ROI_TOP_Y 0 pixels area before the tracking is processed. Value on model counts pixels from the top. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 150 2500 6.0 mm 2510 2.5 mm and 6.0 mm (all models) 384 x 240 320 x 240 640 x 114 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 151: Tracking Parameters - Segmentation Tab

    0 to 100 Range RANGE counting. A lower value breaks people into smaller blobs. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 152 MODE grouped together based on the number of Image Temporal consecutive frames that motion has been detected for adjacent pixels. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 153: Tracking Parameters - Background Tab

    This is for situations where Update DELAY an object is removed from a scene. You can configure the system to quickly snap the value. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 154 15 seconds Period PERIOD Increasing this slows the time required to update a background pixel. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 155: Tracking Parameters - Tracking Tab

    The Dead Count sets how long a track can be (multiples of 12 0 FPS Count COUNT lost and reappear to be counted as same track. increment 1 second) 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 156: Tracking Parameters - Stereo Tab

    1.100000 Diff. DIFF properly. This describes smoothness of the object. If you decrease this value, it discards more areas. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 157 Only Disparity DISPARITY change this value if the sensor is not counting properly. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 158: Tracking Parameters - Sensor Tab

    The visual appearance of change in this field is Brightness BRIGHTNESS not a reliable indication of the sensor's calculations. 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.
  • Page 159: Tracking Parameters - Quality Tab

    MIN_ average intensity can be viewed on the Intensity 0-255 INTENSITY diagnostics page by clicking button in top right. (gs) 6/29/2022 ©2018-2022 Teledyne FLIR Brickstream® 3D Gen 2 Counting Configuration Guide Integrated Imaging Solutions June 2022 Inc. All rights reserved.

Table of Contents