PRODUCT SPECIFICATIONS
| AeraMax™ 200 Air Purifier |
Room Area Served | 200 sq. ft./18 sq. m. |
Power Supply | AC 120V/60Hz |
Power Rate | Low 6W, Turbo 62W |
Fan Speed | 4 Speeds |
Display | Touch Screen |
Control Type | Auto/Manual/Aera+™ |
Air Quality Sensor | Yes |
Filters | 1 True HEPA Filter with AeraSafe™ Antimicrobial Treatment 1 Carbon Filter |
Cleaning System | Carbon Filter True HEPA Filter with AeraSafe™ Antimicrobial Treatment PlasmaTRUE™ |
CADR | 126 Smoke/ 129 Dust/ 124 Pollen |
Color | White |
| FILTER SPECIFICATIONS |
True HEPA Filter Replacement with AeraSafe™ Antimicrobial Treatment | 9287101 |
Carbon Filter Replacement | 9324101 |
For replacement filters please visit: www.fellowes.com
![]()
Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
AIR PURIFIER FEATURES
![Fellowes - AeraMax 200 - AIR PURIFIER FEATURES AIR PURIFIER FEATURES]()
- Ultra-Quiet Operation
This Fellowes AeraMax™ Air Purifier has a four-speed fan with ultra-quiet operation that is ideal for 24 hour use.
- Easy Maintenance
For optimum performance, replace the True HEPA Filter when the HEPA Filter indicator has changed to red, or approximately every 12 months under normal usage conditions. Change the Carbon Filter when the Carbon Filter indicator has changed to red or approximately every 3 months under normal usage conditions. - AeraSmart™ Sensor
This air purifier is equipped with an air quality sensor that automatically adjusts the fan speed to keep your air purified. Blue, amber and red lights indicate the purity of your air. - Four-Speed Setting
From LOW for quiet, energy-efficient operation to TURBO for the most effective cleaning.
Aera+™ Mode
Designed for peak allergy season conditions. Increases air turnover rate by 50% versus low fan setting mode to remove even more allergens from your air.
- Replacement Filter Indicator Lights
Indicate when to replace the True HEPA Filter and Carbon Filter, depending on usage.
FOUR-STAGE PURIFICATION SYSTEM
Removes 99.97% of airborne pollutants.
- Carbon Filter
Removes odors and captures large airborne particulates. - True HEPA Filter
Captures 99.97% of particles as small as 0.3 microns, including ragweed and other allergens, viruses, germs, dust mites, mold spores, pet dander and cigarette smoke. - AeraSafe™ Antimicrobial Treatment
Built-in protection from the growth of odor causing bacteria, mildew and fungi on the True HEPA Filter. - PlasmaTRUE™ Technology
In the final stage of purification, Fellowes® PlasmaTRUE™ Technology creates an ionized field to help safely remove airborne pollutants.
AIR PURIFIER SET-UP
AUTOMATIC OPERATION
The unit is set to default to automatic operation when it is first turned on. The air purifier will automatically sense the amount of impurities in the air, and adjust the fan speed to keep your air purified.
![]()
MANUAL OPERATION
After you turn on the unit, you can switch to manual operation by tapping the fan icon to manually select fan speed.
- LOW, MEDIUM, OR hIGh SETTINGS These levels are recommended for standard daytime use. HIGH will activate automatically when sensors detect poor air quality.
![]()
- TURBO
The TURBO level, the highest fan speed, can be activated manually for maximum air purification.
![]()
AeraSmart™ SENSOR
Air quality indicator shows levels of air quality.
![]()
Blue level indicates air is clean.
Amber level indicates air quality is poor.
Red level indicates high level of pollutants in the air.
Aera+™ MODE
After you turn on the unit, you can switch to Aera+™ mode by pressing the Aera+™ mode icon (
). To go back to auto operation, press Aera+™ mode icon (
) to turn off.
![]()
CARE AND MAINTENANCE
CLEANING
- Clean unit as necessary by wiping with a dry, soft cloth; for stubborn stains, use a warm, damp cloth.
- Do not use volatile fluids such as benzene, paint thinner, or scouring powder, as they may damage the unit surface.
- Keep the unit dry.
![]()
Filter Replacement
The replacement filter indicators will signal when to replace the True HEPA Filter and/ or Carbon Filter. The replacement period will vary depending on the hours of use and air quality. However, under normal usage, most True HEPA Filters need to be replaced annually, and Carbon Filters every three months.
Do not wash and reuse the True HEPA or Carbon Filters—they will not work effectively. Only use Fellowes brand AeraMax™ replacement filters.
![]()
Before replacing any filters, make sure to remove the power plug from the wall outlet.
Replacement Procedure
- Pull out drawer.
![]()
- Pull out the filters that need to be changed.
![]()
- Remove any packaging wrap from the new filter(s).
- Place the new filters in the main unit. (Carbon Filter should always be inserted first, then the True HEPA filter into drawer.)
![]()
- To reset the filter light once a new True HEPA and/or Carbon Filter is installed:
- Be sure that drawer is closed.
- Turn on the unit.
- Locate the filter replacement icon on the display panel.
- Press and hold the filter replacement icon for 3 seconds until unit beeps. HEPA Filter icon will flash amber. Press filter icon area to alternate between HEPA and Carbon.
- Once desired filter is illuminated, press and hold for 3-5 seconds. A short beep will be heard and the light should turn off. Repeat process for each filter as needed.
![]()
TROUBLEShOOTING
Before you call
Solutions to Common Problems
Review this list before you call for service. This list covers problems that are not the result of defective materials or workmanship.
PROBLEM | POSSIBLE SOLUTION |
The unit leaves smoke and odors in the air. | - Make sure the sensor is not blocked or clogged.
- Move the unit closer to the offending odors.
- Replace the filters as needed.
|
The unit seems to produce odors. | - Replace the filters as needed.
|
The unit makes a faint ticking sound. | - This indicates that the PlasmaTRUE function is working.
|
The unit interferes with radio or television reception. | - Because this unit radiates radio frequency energy, we suggest you try one or more of the following:
- For better reception, adjust the television/radio antenna.
- Move the unit away from the affected television/radio.
- Plug the unit power cord into an outlet different from the television/radio power cord.
|
The True HEPA and Carbon Filter indicators remain lit after replacing the True HEPA and/or Carbon Filter. | - Repeat filter light reset instructions.
|
The PlasmaTRUE™ icon is not illuminated. | - Touch and hold PlasmaTRUE™ icon for five seconds until unit beeps.
|
The wrong filter replacement light was reset. | - In the case of unintended filter reset, repeat the filter reset procedure within 5 minutes of unintended reset.
- The filter counter and indicator will return to the status previous to the reset.
|
SAFETY INSTRUCTIONS
Thank you for purchasing a Fellowes® Air Purifier. Please read this manual carefully before using. This product is for indoor use only.
IMPORTANT CAUTIONS AND INSTRUCTIONS FOR USING YOUR AIR PURIFIER
![]()
Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire:
- Do not repair or modify the unit unless specifically recommended in this manual. All repairs should be completed by a qualified technician.
- The plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet.
- Do not alter the plug in any way. If the plug does not fit into the outlet, reverse the plug. If it still does not fit, contact a qualified technician to install a proper outlet.
- Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose.
- Use AC 120V only.
- Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
- Periodically remove dust from the power plug. This will reduce the chance that humidity will accumulate, which increases the risk of electric shock.
- If the power plug is damaged, it must be replaced by the manufacturer or a qualified technician.
- Remove the power plug from the outlet before cleaning the unit. When removing the power plug, grasp by holding the plug itself, never hold by the cord.
- Remove the power plug from the outlet when the unit is not in use.
- Do not handle the power plug with wet hands.
- Do not operate the unit when using indoor smoke-generating insecticides.
- Do not clean unit with benzene or paint thinner. Do not spray insecticides on the unit.
- Do not use the unit where it is humid or where the unit may get wet, such as in a bathroom.
- Do not insert fingers or foreign objects into the air intake or outlet.
- Do not use the unit near flammable gases. Do not use near cigarettes, incense, or other spark-creating items.
- Unit will not remove carbon monoxide emitted from heating appliances or other sources.
- Do not block the intake or outlet vents.
- Do not use near hot objects, such as a stove. Do not use where the unit may come into contact with steam.
- Do not use the unit on its side.
- Keep away from products that generate oily residue, such as a deep fryer.
- Do not use detergent to clean the unit.
- Do not operate without a filter.
- Do not wash and reuse the True HEPA Filter.
- Do not run power cord under carpets or cover with throw rugs.
- When moving machine, always lift using handle.
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Fellowes AeraMax 200, DX55 Manual
Need help?
Do you have a question about the AeraMax 200 and is the answer not in the manual?
Questions and answers