Copeland White Rodgers 1F79 Manual

Non-programmable heat pump thermostat

Advertisement

Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
YOUR THERMOSTAT REPLACES
Description
Heat Pump (No Aux or Emergency Heat)
Heat Pump (with Aux or Emergency Heat)
Standard Heat & Cooling Systems
Standard Heat Only Systems
Millivolt Heat Only Systems – Floor or Wall Furnaces
Standard Central Air Conditioning
Gas or Oil Heat
Electric Furnace
Hydronic (Hot Water) Zone Heat – 2 Wires
Hydronic (Hot Water) Zone Heat – 3 Wires
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC 50/60 Hz.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.
CAUTION
!
Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.
Contents
Installation
Wiring Diagrams
Operation
Troubleshooting
INSTALLATION AND OPERATION INSTRUCTIONS
Yes
Yes
No
No
No
No
No
No
No
No
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury must not
be discarded in household trash. Do not touch any
spilled mercury. Wearing non-absorbent gloves, clean
up any spilled mercury and place in a sealed container.
For proper disposal of a product containing mercury or a
sealed container of spilled mercury, place it in a suitable
shipping container. Refer to www.thermostat-recycle.org
for location to send product containing mercury.
Page
2
3
For California Residents: This product contains a
chemical known to the state of California to cause
4
cancer and birth defects and other reproductive harm.
5
www.copeland.com/white-rodgers
1F79
Non-Programmable
Heat Pump Thermostat
APPLICATIONS
SPECIFICATIONS
PRECAUTIONS
WARNING
!
PART NO. 37- 6499001
Replaces 37-6499C
1632

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the White Rodgers 1F79 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Copeland White Rodgers 1F79

  • Page 1 Contents Page WARNING Installation Wiring Diagrams For California Residents: This product contains a chemical known to the state of California to cause Operation cancer and birth defects and other reproductive harm. Troubleshooting PART NO. 37- 6499001 Replaces 37-6499C www.copeland.com/white-rodgers 1632...
  • Page 2: Installation

    INSTALLATION REMOVING OLD THERMOSTAT Mounting hole Before removing wires from old thermostat’s switching subbase, label each wire with the terminal designation it was removed from. 1. Remove Old Thermostat: A standard heat/cool thermostat consists of three basic parts: a. The cover, which may be either a snap-on or hinge type. b.
  • Page 3: Wiring Diagrams

    WIRING DIAGRAMS THERMOSTAT SYSTEM SYSTEM See Note ** Changeover MONITOR Emergency Relay* SWITCH Compressor Relay Relay Relay Contactor (Stage 2) 24 VAC 120 VAC Neutral * Changeover Relay is energized in COOL when O/B switch is in the “O” position TRANSFORMER Changeover Relay is energized in HEAT when O/B switch is in the “B”...
  • Page 4: Operation

    OPERATION Cooling System NOTE 1. Move SYSTEM switch to COOL position. To prevent static discharge problems, touch side of 2. Press to adjust thermostat setting below room tem- thermostat to release static build-up before touching perature. The blower should come on immediately on high any keys.
  • Page 5: Configuration Menu

    OPERATION Configuration Menu 9 Displays currently programmed set temperature (this is Step Press Button(s) Displayed Press blank when SYSTEM switch is in the OFF position). (Factory Default) to select: 10 “BATT” or is displayed when 2 “AAA” batteries Set SYSTEM are low and should be replaced.
  • Page 6 TROUBLESHOOTING Symptom Possible Cause Corrective Action No Heat 1. Pilot light not lit. Re-light pilot. 2. System Switch not set to HEAT. Set System Switch to HEAT and raise setpoint above room temperature. Verify thermostat and system wires are securely 3.
  • Page 7 NOTES...
  • Page 8 HOMEOWNER HELP LINE: 1-888-725-9797 www.copeland.com/white-rodgers ©2024 Copeland LP.

Table of Contents