Copeland White-Rogers 1F80-361 Installation And Operation Instruction Manual

Programmable electronic digital thermostat

Advertisement

Quick Links

Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Your new White-Rodgers 5-Day/1-Day/1-Day Digital
Thermostat uses the technology of a solid-state
microcomputer to provide precise time/temperature control.
This thermostat offers you the fexibility to design heating and
cooling programs that ft your needs.
Features:
• Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun)
programming with four separate time/temperature periods
per day
• Simultaneous heat and cool program storage
• Preprogrammed temperature control
• Backlit display
This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have it
inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specificatio ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 149°F
Programmable Electronic
INSTALLATION AND OPERATION INSTRUCTIONS
• LCD continuously displays setpoint, and alternately
displays time and room temperature
• Temperature override until next program period
• Manual program override (HOLD temperature)
• Temporary HOLD
• °F/°C convertibility
• Temperature range 45° to 90°F
• RC, RH, C, W, Y, G , O and B terminals
• Optional C terminal (Dual Power option)
• B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
• Program storage in case of power loss
• 2 "AA" alkaline batteries included
For California Residents: This product contains a
chemical known to the state of California to cause
cancer and birth defects and other reproductive harm.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the system
shall conform to Class II circuits per the NEC code.
APPLICATIONS
For use with:
• Standard heat/cool or heat only systems
• Electric heat systems
• Gas or oil fired system
• Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
• Hydronic (hot water or steam) systems
• Single-stage heat pump systems (no auxiliary heat)
• Millivolt systems
DO NOT USE WITH:
• Multi-stage systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems
www.copeland.com/white-rodgers
1F80-361
Digital Thermostat
DESCRIPTION
PRECAUTIONS
WARNING
!
WARNING
!
SPECIFICATIONS
PART NO. 37-6621001
Replaces 37-6621D
1631

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the White-Rogers 1F80-361 and is the answer not in the manual?

Questions and answers

Summary of Contents for Copeland White-Rogers 1F80-361

  • Page 1 DO NOT USE WITH: Operating Humidity Range: • Multi-stage systems 0 to 90% RH (non-condensing) • Systems exceeding 30 VAC and 1.5 amps Shipping Temperature Range: • 3-wire zoned hydronic heating systems -4°F to 149°F PART NO. 37-6621001 www.copeland.com/white-rodgers Replaces 37-6621D 1631...
  • Page 2: Installation

    INSTALLATION REMOVE OLD THERMOSTAT Screw anchors 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
  • Page 3: Wiring Diagram

    WIRING DIAGRAM THERMOSTAT JUMPER C ‡ WIRE THERMOSTAT SYSTEM C ‡ SYSTEM Cooling Heating 24 VAC 120 VAC System Relay System Heating Neutral Relay System HEATING TRANSFORMER 24 VAC 120 VAC NOTE Neutral For 2-wire Heat only, attach to RH and W TRANSFORMER 24 VAC 120 VAC...
  • Page 4: Operation

    OPERATION Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons.Your thermostat consists of two parts: the thermostat cover and the base. To remove the cover, pull it straight out from the base.
  • Page 5: Operating Features

    OPERATION Configuration Menu Step Press Button(s) Displayed (Factory Default) Press to select: COMMENTS HOLD 0 to 8 hrs (in Select temporary Hold time PRGM (0:00) 15 minute increments) and RUN Select FA or SL (Fast or Slow) heating cycle rate HOLD* (FA) Select display backlight OFF or ON...
  • Page 6 OPERATION Enter Heating Program Planning Your Program 1. Move the SYSTEM switch to HEAT. Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your 2. Press PRGM once. “MO TU WE TH FR” (indicating weekday needs, simply press the RUN button to begin running the factory program) will appear in the display.
  • Page 7: Troubleshooting

    OPERATION Enter Cooling Program CHECK YOUR PROGRAMMING Follow these steps to check your thermostat programming one CAUTION final time be ore beginning thermostat operation. 1. Move SYSTEM switch to HEAT position. If the outside temperature is below 50°F, disconnect power to the cooling system before programming. 2.
  • Page 8 Replace batteries and check heat/cool system for Blank Display and/or Keypad Not 2. Voltage Spike or Static Discharge. proper operation. If a voltage spike or static discharge Responding occurs use the Reset Operation listed above. TECHNICAL SUPPORT: 1-888-725-9797 www.copeland.com/white-rodgers ©2024 Copeland LP.