Summary of Contents for IFM KTE Series

  • Page 1 Operating instructions Touch sensor Lamp KTExxx KTVxxx...
  • Page 2: Table Of Contents

    KTExxx KTVxxx Touch sensor Contents Preliminary note ............. Symbols used .
  • Page 3: Preliminary Note

    Touch sensor KTExxx KTVxxx 1 Preliminary note You will find instructions, technical data, approvals, accessories and further information using the QR code on the device / packaging or at documentation.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications...
  • Page 4: Safety Instructions

    KTExxx KTVxxx Touch sensor 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
  • Page 5: Intended Use

    Touch sensor KTExxx KTVxxx 3 Intended use 3.1 Application area While in use the products are exposed to influences which may have an effect on function, life, quality and reliability of the product. It is the customer’s responsibility to ensure that the products are suitable for the intended application. This applies in particular to applications in hazardous areas and with adverse environmental influence such as pressure, chemicals, temperature fluctuations, moisture and radiation as well as mechanical stress, especially if the products are not installed properly.
  • Page 6: Function

    IO-Link is a communication system for connecting intelligent sensors and actuators to automation systems. IO-Link is standardised in the IEC 61131-9 standard. General information on IO-Link at io-link.ifm Input Output Device Description (IODD) with all parameters, process data and detailed descriptions of the device at documentation.ifm.com...
  • Page 7: Sio Mode

    Touch sensor KTExxx KTVxxx • Logging of parameter sets, process values and events • Device description file (IODD - Input Output Device Description) for easy project planning • Standardised electrical connection • Remote maintenance 4.2.2 SIO mode The SIO mode is always active when the device is not connected to an IO-Link master. In SIO mode, the device operates as a digital switch, using the digital switching output and the two digital inputs.
  • Page 8: Static Mode

    KTExxx KTVxxx Touch sensor 4.4.2 Static mode In the [Static mode] setting, any detected actuation (activation) is signalled as long as the activation is present. The output pulse can be delayed using the [dS] setting (switch-on delay). If the switch-on delay time is longer than the duration of the activation, no output pulse is produced. The output pulse can be extended using the [dr] setting (switch-off delay).
  • Page 9: Led Behaviour

    Touch sensor KTExxx KTVxxx Status Device not actuated Device actuated *) Input [LED mode] [Button/Input] [LED colour. Button not pressed] [LED colour. Button pressed] [Inputs] [LED colour. [LED colour. [LED colour. [LED colour. Button not IN1 only] IN2 only] IN1 and IN2] pressed] [PDOut / PLC-con- [PDOut / PLC-controlled]...
  • Page 10: Led Mode

    KTExxx KTVxxx Touch sensor t (s) t (s) Fig. 1: LED behaviour when flashing medium fast Fig. 2: LED behaviour when pulsing medium fast 4.8 LED mode 4.8.1 Button (not applicable to KTV) In this mode, the LED of the connected device cannot be changed via PDOut (IO-Link) or the inputs. This function can be used to integrate signals from other sensors or mechanical contacts into the IO- Link network.
  • Page 11: Pdout / Plc-Controlled

    Touch sensor KTExxx KTVxxx Sensor A Sensor B IO-Link master Fig. 4: LED mode button/input connection example Possible connection accessories - EVC847 and EVC848. 4.8.3 PDOut / PLC-controlled In this mode, the LED of the connected device can only be changed via PDOut (IO-Link). 4.9 Internal temperature The internal temperature of the device can be read.
  • Page 12: Installation

    KTExxx KTVxxx Touch sensor 5 Installation A: Stainless steel device B: Plastic device with symbol disc C: Plastic device with transparent symbol disc and symbol sticker Fig. 5: Observe assembly, sequence and direction of installation Easy mount nut Symbol sticker Sealing ring (outer) Plastic symbol disc (with and without symbol) Touch sensor Symbol disc for stainless steel devices...
  • Page 13 Touch sensor KTExxx KTVxxx When operated without a symbol disc, actuations will not be reliably detected. u Always operate the device with a symbol disc. In case of improper assembly, water, dirt or similar can penetrate between the symbol disc and the sensing face and cause malfunction.
  • Page 14: Electrical Connection

    KTExxx KTVxxx Touch sensor 6 Electrical connection The unit must be connected by a qualified electrician. u Observe the national and international regulations for the installation of electrical equipment. u Disconnect power. u Connect the unit as follows: KTE type: OUT / IO-Link Fig. 6: Cable wiring OUT / IO-Link Fig. 7: Connector wiring...
  • Page 15 Touch sensor KTExxx KTVxxx IO-Link Fig. 9: Connector wiring u Lay the cable as straight as possible and do not coil it.
  • Page 16: Set-Up

    KTExxx KTVxxx Touch sensor 7 Set-up u Install the device completely. u Check the electrical connection. u Make the required settings. u Check the function of the device.
  • Page 17: Parameter Setting

    Depending on the parameter setting, the parameters available in the menu may change. Requirements for parameter setting via the IO-Link interface: ü A suitable parameter setting software, e.g. ifm moneo|configure ü The Input Output Device Description (IODD) for the device, see documentation.ifm.com...
  • Page 18: Configuration Of The Switching Outputs

    KTExxx KTVxxx Touch sensor Actuation possible (with): Not triggered by: Suppresses soiling: Soiling Standard Splash water Medium Soiling Standard Splash water High Soiling Standard Splash water 8.1.2 Configuration of the switching outputs Parameter Value / Factory setting Description PNP (0) Output polarity for the switching outputs. NPN (1) SSC Config Logic High active (0)
  • Page 19 Touch sensor KTExxx KTVxxx Parameter Value / Factory setting Description RGB custom colour Red (RGB - red component 0...255): 254 Colour defined by the customer (2) Green (RGB - green component 0...255): Blue (RGB - blue component 0...255): 0 LED colour. Button Off (0) LED colour for the status: not pressed...
  • Page 20: Other Parameters

    KTExxx KTVxxx Touch sensor Parameter Value / Factory setting Description LED behaviour. IN1 Continuous lighting​ (0) LED behaviour for the status: only Slow flashing (1) • IN1 active and IN2 inactive. Medium-fast flashing (2) Fast flashing (3) Slow pulsing (4) Medium-fast pulsing (5) Fast pulsing (6) LED colour.
  • Page 21: Commands

    Touch sensor KTExxx KTVxxx 8.2 Commands Command Description Reset to factory settings Resets all parameters of the device to the factory settings. The switching cycles counter is not reset. Reset counter to zero Resets the switching cycles counter to 0. Locator Start The visual indicators (LEDs) of the device are switched to the localization dis- play pattern, making it easier to spot a device in an application.
  • Page 22: Troubleshooting

    KTExxx KTVxxx Touch sensor 9 Troubleshooting u Clean the device to remove any soiling. u Check the correct installation of the device. u Carry out a reset. u Check the seals. u If necessary, adjust the sensitivity or environment setting. u If necessary, set a switch-on delay.
  • Page 23: Maintenance, Repair And Disposal

    Touch sensor KTExxx KTVxxx 10 Maintenance, repair and disposal If used correctly, the unit is maintenance-free. u Keep the sensing face and any clear spaces free from deposits and foreign bodies. u It is not possible to repair the unit. u After use, dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.