Download Print this page

Advertisement

Quick Links

TX400
HMI/PLC Series
Instructions for Use

Advertisement

loading
Need help?

Need help?

Do you have a question about the TX400 HMI Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for turck TX400 HMI Series

  • Page 1 TX400 HMI/PLC Series Instructions for Use...
  • Page 2: Table Of Contents

    Access to the CODESYS WebVisu ....................  21 Configuring ............................ 22 Configuring the system settings................ 22 Operating............................ 25 LED displays ........................ 25 V01.00 | 2025/01 | 2 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 3 12.1 Returning devices ...................... 27 13 Disposal..............................  27 14 Technical data...........................  28 15 Turck branches — contact data .................... 31 V01.00 | 2025/01 | 3 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 4: About These Instructions

    If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com. V01.00 | 2025/01 | 4 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 5: Notes On The Product

    Connector for serial interface Mounting brackets Quick Start Guide Turck service Turck supports you in your projects – from the initial analysis right through to the commission- ing of your application. The Turck product database at www.turck.com offers you several soft- ware tools for programming, configuring or commissioning, as well as data sheets and CAD files in many export formats.
  • Page 6: For Your Safety

    The product is designed according to state of the art technology. Residual hazards, however, still exist. Observe the following safety instructions and warnings in order to prevent danger to persons and property. Turck accepts no liability for damage caused by failure to observe these safety instructions.
  • Page 7: Product Description

    7" TX410 10" TX415 15" Device overview 147 [5.79] [3.74] [4.21] [0.31] [1.46] 135 [5.31] mm [Inch] Fig. 1: Dimensions TX405 V01.00 | 2025/01 | 7 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 8 270 [10.63] mm [Inch] Fig. 3: Dimensions TX410 422 [16.61] [10.04] [10.51] [0.39] [1.77] 410 [16.14] mm [Inch] Fig. 4: Dimensions TX415 V01.00 | 2025/01 | 8 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 9: Properties And Features

    ≤ 4 GB for a single file ≤ 32 GB Accessories 4.4.1 Power supply Type Description 100002938 TX-PSC TX power supply onnector V01.00 | 2025/01 | 9 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 10: Installing

    Tighten the fastening screws until the brackets are firmly in contact with the device. The minimum tightening torque to guarantee protection class IP66 is 0.75 Nm. V01.00 | 2025/01 | 10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 11: Grounding The Device

    (1 MΩ resistor with 4.7 nF capacitor connected in parallel). „ The power supply must have double or reinforced insulation. Fig. 7: Power supply – wiring V01.00 | 2025/01 | 11 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 12: Connecting

    Fig. 9: Power supply connector TX… NOTE The power connector is part of the scope of delivery and can be ordered as spare part [} 9]. V01.00 | 2025/01 | 12 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 13: Connecting The Device To Ethernet

    The GND and CAN-GND pins are isolated from each other. SHIELD is con- nected internally to earth via terminal 3 of the voltage supply connection. V01.00 | 2025/01 | 13 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 14: Commissioning

    DHCP server in the network, via Turck Automation Suite (TAS) or via the Turck Service Tool. In addition, the device can also be addressed directly via the IP address of ETH1 using a web browser, Turck Automation Suite (TAS) or the Turck Service Tool.
  • Page 15: Web Server Login

    The IP address can be set via the system settings on the touch screen of the device or via the device’s web server. The IP address via which the device is connected to the PC via Ethernet can also be set via the Turck Service Tool or via the Turck Automation Suite (TAS). 7.5.1 Setting the IP address via the web server „...
  • Page 16 Set the IP address, the subnet mask, etc. under Network interface and save the changes. Fig. 13: Web server, network interface V01.00 | 2025/01 | 16 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 17: Adjusting Network Settings Via Tas (Turck Automation Suite)

    „ Click Scan network. Fig. 14: Home screen in TAS ð TAS shows the connected devices. Fig. 15: Found devices in TAS V01.00 | 2025/01 | 17 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 18 Fig. 17: Changing network settings in TAS NOTE An IP address assigned via TAS is not stored permanently in the switch. V01.00 | 2025/01 | 18 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 19: Setting The Ip Address Via Turck Service Tool

    Turck Service Tool shows the connected devices. NOTE Clicking the device's IP address opens the web server. Fig. 19: Turck Service Tool – found devices V01.00 | 2025/01 | 19 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 20 Change the IP address and the net mask, if necessary. „ Accept the changes with Set in device. Fig. 20: Turck Service Tool – changing the IP configuration V01.00 | 2025/01 | 20 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 21: Programming With Codesys

    EtherCAT OPC-UA 7.6.2 Access to the CODESYS WebVisu The CODESYS WebVisu is accessed via port 8085: http://<<IP address>>:8085/webvisu.htm Example: http://192.168.1.40:8085/webvisu.htm V01.00 | 2025/01 | 21 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 22: Configuring

    In addition to the options in user mode, the system mode includes additional commands for system upgrade and recovery. Device without TX VisuPro runtime Device with software error V01.00 | 2025/01 | 22 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 23 Services Activate/deactivate services (e.g. OpenSSH server, bridge, cloud, router, SNMP, logging) V01.00 | 2025/01 | 23 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 24 By default, the device is restarted in user mode via the "Main OS" option. The "Configuration OS" option restarts the device directly in System Settings in System Mode. V01.00 | 2025/01 | 24 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 25: Operating

    LED orange (left LED) Meaning No Ethernet connection Ethernet connection established LED green (right LED) Meaning No data transfer Flashing Data transfer V01.00 | 2025/01 | 25 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 26: Troubleshooting

    If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type. V01.00 | 2025/01 | 26 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 27: Maintenance

    The device the lithium battery must be disposed of properly in accordance with WEEE Directive 2012/19/EU and does not belong in normal household waste. V01.00 | 2025/01 | 27 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 28: Technical Data

    176 × 136 mm Installation depth (D) 29 + 8 mm 29 + 8 mm Weight 0.5 kg 0.7 kg V01.00 | 2025/01 | 28 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 29 For applications requiring compliance with EN 61131-2 and specifically in reference to 10 ms voltage dips, the minimum power supply voltage is 18 VDC. V01.00 | 2025/01 | 29 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 30 5…9 Hz, 7 mm EN 60068-2-6 9…150 Hz, 1 g Shock ± 50 g, 11 ms, EN 60068-2-27 3 pulses per axis V01.00 | 2025/01 | 30 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 31: Turck Branches - Contact Data

    Via San Domenico 5, IT-20008 Bareggio (MI) www.turckbanner.it Japan TURCK Japan Corporation ISM Akihabara 1F, 1-24-2, Taito, Taito-ku, 110-0016 Tokyo www.turck.jp V01.00 | 2025/01 | 31 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 32 United Kingdom TURCK BANNER LIMITED Blenheim House, Hurricane Way, GB-SS11 8YT Wickford, Essex www.turckbanner.co.uk Turck Inc. 3000 Campus Drive, USA-MN 55441 Minneapolis www.turck.us V01.00 | 2025/01 | 32 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 33 Over 30 subsidiaries and 60 representations worldwide! 100051648 | 2025/01 100051648 www.turck.com...