Charging the battery .................... 22 Using the touchscreen.................... 22 Initial commissioning .................... 22 Web server login...................... 22 Setting the IP address.................... 23 7.5.1 Setting the IP address via the web server ................ 23 7.5.2 Setting the IP address via Turck Service Tool .............. 24 V01.00 | 2020/11...
We make every effort to ensure that these instructions are as informative and as clear as pos- sible. If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com. V01.00 | 2020/11...
TX707FB-… Ident no. 100007471 Year/week of production A2048 Serial number (S.N.) AA… Internal version ID of the product (V) 121… Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
45472 Mülheim an der Ruhr Germany Turck supports you with your projects, from initial analysis to the commissioning of your applic- ation. The Turck product database contains software tools for programming, configuration or commissioning, data sheets and CAD files in numerous export formats. You can access the product database at the following address: www.turck.de/products...
Page 8
For further inquiries in Germany contact the Sales and Service Team on: Sales: +49 208 4952-380 Technology: +49 208 4952-390 Outside Germany, please contact your local Turck representative. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
Properties and features Gateway function with OPC UA Server and Client (with TX VisuPro) Safe connection to Turck Cloud with complete network isolation MQTT for connecting all common cloud systems (with TX VisuPro) CODESYS V3 PLC runtime with selection of the most important I/O protocols...
Specification Format FAT, FAT32 Max. size Limited by FAT32 specifications ≤ 4 GB for a single file ≤ 32 GB Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
USB 2.0 extension cable, male (A) to female (A), 5 m 6827390 USB 2.0 EXTENSION ACTIVE 5M USB 2.0 extension cable, male (A) to female (A), with active repeater, 5 m NOTE You will find further accessory products under www.turck.com. V01.00 | 2020/11...
The minimum tightening torque for the fixing screws of the mounting brackets is 130 Ncm. The mounting brackets must rest firmly on the device. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Fasten devices in the mounting cutout The devices are fixed in the mounting cutout with mounting brackets. Mount the brackets as follows. Fig. 6: Insert the brackets Tighten the fastening screws until the brackets are firmly in contact with the device. The minimum tightening torque to guarantee protection class IP66 is 130 Ncm.
Grounding the device Connect terminal 3 of the supply connector to the ground terminal. General instructions for device grounding All the electronic devices in the control system must be properly grounded. Carry out grounding according to the applicable regulations. ...
Fig. 11: Power connectorTX7… NOTE The power connector is part of the scope of delivery and can be ordered as spare part [} 13]. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Connecting the device to Ethernet The device has two RJ45 Fast Ethernet sockets and one RJ45 Gigabit Ethernet socket for con- nection to Ethernet. Connect the device to Ethernet using a standard Ethernet cable. Use a Gigabit-capable Ethernet cable to connect the devices to a Gigabit network. Default settings of the Ethernet ports The Ethernet ports are set to DHCP at delivery.
RS232 Serial TX-IO-DX06 Compact I/O TX-IO-XX03 Multifunction I/O 1 TX705: TX-EXTEND or other extension module with ex- tension slot necessary Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Module Application Max. number of modules Interface type/ Bus extension communication connector interface TX-DP-S PROFIBUS-DP slave TX-UMTS UMTS modem Serial TX-EXTEND Extension module 1 for TX705 None The column max. modules refers to the max. number of modules which can be plugged into the HMI (all slots).
If the simple link causes a conflict with an already active WebVisu application, the system set- tings can also be accessed directly via the following link: https://IP/machine_config Example access: https://192.168.1.24/machine_config Username: admin Password: admin Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Setting the IP address The IP address can be set via the system settings on the touch screen of the device, the device’s web server or via the Turck Service Tool. 7.5.1 Setting the IP address via the web server ...
Turck Service Tool shows the connected devices. NOTE Clicking the device's IP address opens the web server. Fig. 17: Turck Service Tool – found devices Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Change the IP address and the net mask, if necessary. Accept the changes with Set in device . Fig. 18: Turck Service Tool – changing the IP configuration Programming with CODESYS The devices are delivered with a pre-installed CODESYS runtime.
Project transfer via a USB stick Create an update package with TX VisuPro and copy it to a USB stick. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Configuring The devices have an integrated User interface and a web server for configuring the system. The user interface is based on HTML pages accessible via port 443 using a Web browser (Fire- fox V.79 Chrome V.44 or higher). Alternatively, the system settings can be called and operated via a VNC client.
Page 28
("user”). The administrator has full access to the sys- tem settings (updates of the BSP and other system components). The standard user has some restrictions. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Operating LED displays The device has the following LED displays: Status of the Ethernet ports LED orange (left LED) Meaning No Ethernet connection Ethernet connection established LED green (right LED) Meaning No data transfer Blinking Data transfer V01.00 | 2020/11...
If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Observe our return acceptance conditions when returning the device to Turck. 12.1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed. The decontamination declaration can be downloaded from https://www.turck.de/en/retoure-service-6079.php and must be completely filled in, and affixed securely and weather-proof to the outside of the packaging.
2 × Host V2.0, max. 500 mA max. 500 mA SD card Extension slot (plug-in) Max. number of plug-in modules Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 33
TX707FB-P3CV01 TX715FB-P3CV01 Power supply Rated value 24 VDC (SELV) 24 VDC (SELV) Admissible voltage range 18…32 VDC 18…32 VDC Current consumption at 24 VDC Max. 0.7 A Max. 1.2 A Dimensions Housing (W × H) 217 × 177 mm 450 × 295 mm Housing (W ×...
Page 34
(landscape format). Fig. 20: Viewing angle Viewing angle From the top From the bottom From the left From the right Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Appendix: Approvals and markings Approvals Immunity/emission For industrial environments: EN 61000-6-2 EN 61000-6-4 Food and Beverage Front panel and gasket DIN EN1672-2 2 EHEDG / FDA 21 CFR 177.2006 cULus (UL File No. E484727) UL 61010-1, 3rd Edition and UL 61010-2-201, 1st Edition CAN/CSA C22.2 No.
Page 36
Over 30 subsidiaries and over 60 representations worldwide! 100022974 | 2020/11 100022974 www.turck.com...
Need help?
Do you have a question about the TX700FB and is the answer not in the manual?
Questions and answers