Copeland White Rodgers 50A56-956 Installation Instructions Manual

Integrated furnace control

Advertisement

Quick Links

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
The 50A56-956 is an automatic gas interrupted ignition control
that employs a microprocessor to continually monitor, analyze,
and control the proper operation of the gas burner, inducer,
and fan.
Signals interpreted during continual surveillance of the thermostat
and fame sensing element initiate automatic ignition of the
burner, sensing of the fame, and system shut-off during normal
operation.
These controls incorporate system fault analysis for quick gas
fow shut-off, coupled with automatic ignition retry upon sensing
a fault correction.
Kit includes: 1) Ignition Control
3) ) Install Sheet
Installation should be done by a qualifed heating and air
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualifed heating and air conditioning
contractor or licensed electrician.
Do not exceed the specifcation ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
Following installation or replacement, follow manufacturer's
recommended installation/service instructions to ensure proper
operation.
CAUTION
!
Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.
CONTENTS
Description ........................................................ 1
Precautions ....................................................... 1
Specifcations .................................................... 2
Installation ......................................................... 3
Operation ........................................................... 6
Troubleshooting ................................................... 8
2) Metal Control Box
www.copeland.com/white-rodgers
50A56-956
Integrated Furnace Control
INSTALLATION INSTRUCTIONS
50A56-956 Cross Reference Information
York
S1-33102956000
S1-03101266000
S1-03109167000
S1-03101284000
S1-03101933000
S1-03101973000
S1-03101267000
S1-03101972000
S1-03101267001
265901
S1-03100662000
265902
S1-03101250000
539617
S1-33103010000
WARNING
!
Failure to comply with the following warnings could result
in personal injury or property damage.
FIRE HAZARD
• Do not exceed the specified voltage.
• Replace existing control with exact model and
dash number.
• Protect the control from direct contact with water
(dripping, spraying, rain, etc.).
• If the control has been in direct contact with
water, replace the control.
• Label all wires before disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
• Route and secure wiring away from flame.
SHOCK HAZARD
• Disconnect electric power before servicing.
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line
hot wires.
EXPLOSION HAZARD
• Shut off main gas to appliance until installation
is complete.

DESCRIPTION

White-Rodgers
50A56-242
50A56-243

PRECAUTIONS

PART NO. 37-7475001
Replaces 37-7475B
1419

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the White Rodgers 50A56-956 and is the answer not in the manual?

Questions and answers

Summary of Contents for Copeland White Rodgers 50A56-956

  • Page 1: Table Of Contents

    Precautions ............1 hot wires. Specifcations ............ 2 Installation ............3 EXPLOSION HAZARD Mounting & Wiring • Shut off main gas to appliance until installation Operation ............6 is complete. Troubleshooting ........... 8 PART NO. 37-7475001 Replaces 37-7475B www.copeland.com/white-rodgers 1419...
  • Page 2: Specifications

    SPECIFICATIONS OPERATING TEMPERATURE RANGE: ELECTRICAL RATINGS [@ 77°F (25°C)]: -40° to 176°F (-40° to 80°C) Input Voltage: 25 VAC 50/60 Hz HUMIDITY RANGE: Max. Input Current @ 25 VAC: 0.45 amp 5% to 93% relative humidity (non-condensing) Relay Load Ratings: MOUNTING: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)
  • Page 3: Installation

    INSTALLATION CAUTION WARNING Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the Failure to comply with the following warnings could result thermostat. in personal injury or property damage. MOUNTING AND WIRING FIRE HAZARD •...
  • Page 4 TYPICAL SYSTEM WIRING DIAGRAM NEUTRAL (LINE) (LINE) 120 VAC 24 VAC CLASS II TRANSFORMER 24 VAC 50A56 LO COOL HI COOL CIRCULATOR HEAT BLOWER PARK PARK LINE XFMR INDUCER IND-N IGN-N IGNITOR HUMIDIFIER CIR N LINE N XFMR N HUM N ELECTRONIC EAC N AIR CLEANER...
  • Page 5 TYPICAL SYSTEM WIRING TABLE 50A56 TERMINAL SYSTEM COMPONENT TERMINAL TYPE CONNECTION low voltage thermostat W terminal (or equivalent) low voltage thermostat G terminal (or equivalent) Terminal low voltage thermostat R terminal (or equivalent) block with Y/Y2 low voltage thermostat Y terminal (or equivalent) captive (2nd wire from Y terminal goes to 24 VAC HOT side of screws...
  • Page 6: Operation

    OPERATION OPTION SWITCHES If fame is established for more than 10 seconds after ignition, the controller will clear the ignition attempt (or retry) counter. The shunt jumper (E34) on the 50A56 control are used to If fame is lost after 10 seconds, it will restart the ignition determine the length of the heat delay-to-fan-off periods.
  • Page 7: System Lockout

    OPERATION To reset the control after system lockout, do one of the MANUAL FAN ON MODE following: If the thermostat fan switch is moved to the ON position, the Interrupt the call for heat or cool at the thermostat for at least optional electronic air cleaner and circulator fan are energized.
  • Page 8: Troubleshooting

    TROUBLESHOOTING Green Amber Error/Condition Comments/Troubleshooting Flash Flash Flash Slow Normal operation No fault. Flame sensed when no Verify the gas valve is operating and shutting down properly. Flame fame should be present in burner assembly should extinguish promptly at the end of the cycle.
  • Page 9 NOTES...
  • Page 10 NOTES...
  • Page 11 4.825" 7.0" 7.0" Note: Confirm actual size of template before using. 4.825" Figure 1: Hole Template...
  • Page 12 TECHNICAL SUPPORT: 1-888-725-9797 www.copeland.com/white-rodgers ©2024 Copeland LP.