Furuno AD-100 Operator's Manual
Furuno AD-100 Operator's Manual

Furuno AD-100 Operator's Manual

A-d converter

Advertisement

Quick Links

OPERATOR'S MANUAL
A-D CONVERTER
AD-100
MODEL
www.furuno.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AD-100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Furuno AD-100

  • Page 1 OPERATOR'S MANUAL A-D CONVERTER AD-100 MODEL www.furuno.com...
  • Page 6: Table Of Contents

    TABLE OF CONTENTS SPECIFICATIONS ............................ -1- EQUIPMENT LIST............................ -2- CHAPTER 1 OPERATION ........................1-1 1. FRONT PANEL..........................1-1 2. OPERATION........................... 1-1 CHAPTER 2 MAINTENANCE ......................2-1 to 2-4 1. FUSE REPLAEMENT ........................2-1 2. MINOR TROUBLESHOOTING ....................... 2-1 3. SELF TEST ............................ 2-2 1) Sequence..........................
  • Page 7: Specifications

    SPECIFICATIONS OF AD-100 A-D CONVERTER General The AD-100 A-D converter converts the gyro compass reading into digital coded bearing data and display it on a 4 digit LED display. The digital bearing output may be sent to navigation equipment such as radar, GPS navigator and autopilot.
  • Page 8: Complete Set

    EQUIPMENT LIST COMPLETE SET Name Type Code NO. Remarks Main Unit AD-100 000-040-104 Accessories FP64-00400 000-040-107 Installation Materials CP64-00500 000-040-106 Spare Parts SP64-00400 000-040-105 ACCESSORIES Name Type Code NO. Remarks Tapping Screw 5x20 SUS304 000-802-081 Knob Bolt KT-B M6x10 000-861-924...
  • Page 9: Chapter 1 Operation

    (2) Adjust the brightness of the Bearing Display and the backlighting of the keys with the Dimmer Control. (3) The Bearing Display is blinking, which means the data is not yet sending out from AD-100. (4) Once you press HOLD key, the data is sent out changing the Bearing Display from blink to light.
  • Page 10: Chapter 2 Maintenance

    *Check the connection with and “359.9” flashes. signal breaking detection is the Gyrocompass. activated. *Press COUNT-UP or COUNT-DOWN key to match the AD-100 indication with the Gyrocompass indication, and then press HOLD key. “999.9” flashes *Stator signal breaking detection *Check the connection with is activated.
  • Page 11: Self Test

    Defective CR22 BLINK Power supply and CPU are normal. 3. SELF TEST The AD-100 employs Self tests to check it for proper operation. These are as follows. *Display LED test *Analog Data Input Test *DIP SW Setting Display *Program Version Display...
  • Page 15: Chapter 3 Installation

    Standard compass: 1.10 m Steering compass: 0.80 m NOTE FURUNO will not assume responsibility for damage caused by water spray. Mounting the unit The equipment can be mounted on the underside of table or a table top. Ensure the mounting location is strong enough to support the unit under the condition of shock and vibration normally encountered onboard the vessel.
  • Page 21: Dip Switch And Jumper Wire Setting

    1) DIP switch and jumper wire setting Revised at Dec. 21, 2010 Revised at Apr. 9. 2001 e l l a t l a t l a t l a t l ) - ( i a l a t l a t l CMZ-700 DC step...
  • Page 22: Default Setting

    Default setting This unit is set at the factory for connection with the gyrocompass specifications tabulated below. 1) Type : AC synchro 2) Frequency : 50/60Hz 3) Rotor Voltage : Between 60VAC and 135VAC 4) Stator Voltage : Between 60VAC and 135VAC 5) Gear Ratio : 360X 6) Supplied Power...
  • Page 23: Function Of Dip Switches And Jumper Wires

    (5) Gear ratio Gear Ratio SW1-1 SW1-2 SW1-3 X360 X180 (6) Power supply voltage Voltage 20 to 45VAC 30 to 135VAC 20 to 60VDC 40 to 135VDC (7) Output data transmitting interval and output sentence, version no. and baud rate. SW2-5 SW2-6 Output Version no.
  • Page 24 Segment Function Setting SW1-7, -8 Frequency SW1-7 SW1-8 50/60Hz 400Hz 500Hz (2) DIP Switch SW2, SW3 Segment Function Setting SW2-1 Rotor Voltage SW2-1 20 to 90VAC 30 to 135VAC SW2-2, Stator Voltage SW2-2 SW2-3 SW2-3 20 to 90VAC or 20 to 60VAC 30 to 135VAC or 40 to 100VDC SW2-4 Selftest...
  • Page 25 Jumper JP2 Segment Function Setting Stator Voltage 20 to 70VAC or 20 to 100VDC 40 to 135VAC Jumper JP3 Segment Function Setting Rotor Voltage 20 to 70VAC 40 to 135VAC Jumper JP4 Segment Function Setting Power Supply 20 to 45VAC or 20 to 60VDC 30 to 135VAC or 40 to 100VDC Jumper JP5 Segment...
  • Page 27: Chapter 5 Digital Interface

    CHAPTER 5 DIGITAL INTERFACE Output sentences HDT, VHW Transmission interval Selectable among 25ms, 100ms, 200ms, and 1s. Note: For 25ms, 100ms or 200ms. only HDT is output. The 25ms setting sets baud rate to 38,400 bps. Data transmission Data is transmitted in serial asynchronous form in accordance with the standard referenced in 2.1 of IEC 61162-1.
  • Page 28 HDT - Heading - true Actual vessel heading in degrees true produced by any device or system producing true heading. $HEHDT, x.x, T*hh<CR><LF> Checksum Heading, degrees true Note: For NMEA0183 Ver.1.5 setting (SW3-1: OFF), checksum is null field. VHW - Water speed and heading The compass heading to which the vessel points and the speed of the vessel relative to the water.
  • Page 32 Nishinomiya, 662-8580, JAPAN A : SEP 1990 Printed in Japan All rights reserved. U2 : MAR . 05, 2012 Pub. No. OME-43400-U2 *00080227711* *00080227711* (ETMI ) AD-100 *00080227711* *00080227711* * 0 0 0 8 0 2 2 7 7 1 1 *...