Download Print this page

fadini TALOS 9450 Instruction, Use And Maintenance Manual

Hide thumbs Also See for TALOS 9450:

Advertisement

Quick Links

GB
Instruc on, use and maintenance manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the TALOS 9450 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for fadini TALOS 9450

  • Page 1 Instruc on, use and maintenance manual...
  • Page 2: General Warnings

    CE DECLARATION OF CONFORMITY of the manufacturer: Meccanica Fadini S.r.l. (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under its own responsibility that TALOS is in compliance with the Direc ve 2006/42/EC on machinery, moreover: is to be sold and installed as a comprehensive “Automa c System”, including the accessories and components as recommended by the Manufacturing Company.
  • Page 3: Symbol Legend

    (mm) thickness (mm) resistance resistance (mm) (mm) TALOS 9450 320.000 TALOS 9651 450.000 TALOS 9450/HRC 420.000 TALOS 9651/HRC 550.000 TALOS 9460 320.000 TALOS 9661 450.000 TALOS 9460/HRC 420.000 TALOS 9661/HRC 550.000 TALOS 9470 320.000...
  • Page 4: Main Components

    3. MAIN COMPONENTS Cylinder head made of Release spanner aluminium fi ed with rubber with triangular socket end edge and 12 amber-colour integrated LED lights Approved retro-reflec ng, micro-prisma c adhesive film Cover ø 275 retractable, cylindrical post. plate 500, 600, 700, 800 mm height op ons Thickness: 4 mm or 12 mm Casing for concrete...
  • Page 5 4. MAIN COMPONENTS FOR INSTALLATION 230 V - 50 Hz INTERNAL SIDE TO PROTECT EXTERNAL SIDE List of all the possible accessories for system opera ons and safety (see general catalogue). General indica ve diagram: 1. Electronic controller with radio receiver 2.
  • Page 6 5. INSTALLATION 5.1 REMOVE THE BOLLARD FROM ITS CASING Remove the M10 screws on the squared cover plate Screw the two li ing rings down into the pre-holed seats Remove the inner fixing plate NOTE WELL: make sure the Carefully hoist and remove the inner ground cable is assembly of the bollard by a winch.
  • Page 7 5.2 CEMENTING THE CASING A pit is to be dug into the ground following the dimensions as indicated in Pic. 5. EXTERNAL SIDE INTERNAL SIDE TO PROTECT 43 cm Road surface 21 cm 21 cm and walking level 6 - 12 cm 6 - 12 cm height constraint P (mm)
  • Page 8 The upper level of the founda on casing is to be 1-2 cm higher than the surrounding walking surface, in order to limit the amount of water that may get inside it. Cast concrete all around the casing up to 5-10 cm from walking level. Wait all the me required for concrete to set firmly (at least 7 days) and complete the finishing of the road surface.
  • Page 9 ARRANGING FOR THE MAGNETIC LOOPS (OPTIONAL) INTERNAL SIDE IMPORTANT: make sure that the area near and below the TO PROTECT ground level where the accessories are installed is clear from electromagne c sources to prevent interference problems with the detec ons of the loops and with any other electronic device to control the installa on.
  • Page 10 5.4 ELECTRIC CONNECTIONS TO THE ELECTRONIC CONTROLLER ELPRO S40 The electronic controller Elpro S40 is to be installed in a dry and protected place to prevent unauthorized ac ons. Make sure that all the electric cables of the command and safety accessories are properly led to the controller (Pic. 3). Through the previously laid corrugated tube pull a mul core cable, type BUT FLESSIBILE FG 7OR 12x1,5 mm²...
  • Page 11 The bollard comes pre-wired (electric motor, limit switches, LEDs and possible op onal items such as: beeper, solenoid valve and pressure switch). Connec ons are in a dedicated water ght box. Remove the connector from the junc on box and bring the connec ons to the respec ve terminals by means of a mul core cable (not supplied with the equipment).
  • Page 12: Solenoid Valve

    FIRST RUNNING TEST ATTENTION: supply the system with power only when wiring is completed. Once the bollard and all of the the safety (make sure that all the NC contacts in the Elpro S40 controller are actally closed) and command accessories are finally installed, the respec ve connec ons to Elpro S40 done and the risk analysis completed, the first running test can be carried out.
  • Page 13 Once sa sfied that voltage is properely supplied to the system, and provided that the LEDs of the limit switches are correctly switched (post down L8 is OFF), by the first pulse the post should rise, if not swap the motor live connec ons (in Elpro S40) a er voltage supply to the system has been switched off.
  • Page 14 BOLLARD WITH SOLENOID VALVE (OPTIONAL ACCESSORY) With the version of the bollard where a solenoid valve (24 Vdc) is fi ed, in case of power failure, the post is allowed to lower by itself flat to ground level. If a solenoid valve is fi ed, a voltage stabilizer is also required: this accessory is absolutely necessary and is to be fi ed between the solenoid valve power output (terminals 22 and 23) and the solenoid valve.
  • Page 15 (clockwise) lowering Pic. 23 OPERATIONS FOR ORDINARY ROUTINE MAINTENANCE OF FADINI AUTOMATIC BOLLARDS (EVERY SIX MONTHS) The standard maintenance rou ne sequence is as follows: • Clean the ground cylinder and suck all material se lements. • Clean water drains located at the bo om of the ground cylinder and/or excava on pit.
  • Page 16: Maintenance Record

    NOTE WELL: this document must record any ordinary and extraordinary services including installa on, maintenance, repairs and replacements to be made only by using Fadini original spare parts. This document, for the data included in it, must be made available to authorized inspectors/officers, and a copy of it must be handed over the end user/s.
  • Page 17 1) Installa on opera ons, tes ng, analysis of the risks and future maintenance are to be executed by qualified and authorized technicians in compliance with the exis ng regula ons (www.fadini.net/supporto/download) 2) This automa c system is intended to be exclusively used for the applica ons described in this manual, including all of the safety and command accessories, at least as required.
  • Page 18 Meccanica Fadini S.r.l. is not liable for any possible damages derived from incorrect use or from any use not indicated in this manual, furthermore it is not answerable for malfunc oning caused by the use of materials or accessories not approved by the company itself.
  • Page 19 4 mm 4 mm / HRC 52.000 J 70.000 J 320.000 J 420.000 J 1.000 1.400 2.100 1.000 1.400 2.100 vehicle vehicle MASS (kg) MASS (kg) Various factors, such as the compac on index, soil permeability Various factors, such as the compac on index, soil permeability coefficient and kind of concrete may reduce the values indicated in the coefficient and kind of concrete may reduce the values indicated in the diagram even significantly.
  • Page 20: Technical Data

    1 MPa (10 bar) S355J2H (12 mm) steel Working temperature -20 °C ÷ +80 °C AISI 304 inox / AISI 316 inox Oil type Oil Fadini - code 708L brushed SS steel Oil reservoire 3 liters constraint 200 constraint 400...