Cisco CSF-1230 Hardware Installation Manual
Cisco CSF-1230 Hardware Installation Manual

Cisco CSF-1230 Hardware Installation Manual

Secure firewall

Advertisement

Quick Links

Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware
Installation Guide
First Published: 2025-04-09
Last Modified: 2025-04-09
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSF-1230 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cisco CSF-1230

  • Page 1 Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide First Published: 2025-04-09 Last Modified: 2025-04-09 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Cisco has more than 200 offices worldwide. Addresses and phone numbers are listed on the Cisco website at www.cisco.com/go/offices. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: https://www.cisco.com/c/en/us/about/legal/trademarks.html.
  • Page 3: Table Of Contents

    Prevent ESD Damage Site Environment Site Considerations Power Supply Considerations Rack Configuration Considerations C H A P T E R 3 Rack-Mount the Chassis Unpack and Inspect the Chassis Ground the Chassis Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 4 Contents Rack-Mount the Chassis C H A P T E R 4 Installation, Maintenance, and Upgrade Replace the SSD Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 5: Overview

    • Power Cord Specifications, on page 17 Features The Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 security appliances are powered by a network processor (DPU) that delivers high performance on network/security workloads with impressive power efficiency. See Product ID Numbers, on page 16 for a list of the product IDs (PIDs) associated with the Secure Firewall CSF-1230, CSF-1240, and CSF-1250.
  • Page 6 Overview Features Figure 1: Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 The following table lists the features for the Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250. Table 1: Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Features Feature CSF-1230 CSF-1240 CSF-1250...
  • Page 7 OFF before you connect AC power for the first time. The chassis powers on and boots up as soon as the AC power is applied when the power button is in the ON position. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 8 Redundant power Two fixed fans The fans are internal; there is no user access. The fan is not field-replaceable; you must return the chassis to Cisco for fan replacement. See the Cisco Returns Portal for more information.
  • Page 9: Usage Scenarios

    FAT-32 and mount the partition to disk1 again; however, data might be lost. Usage Scenarios Here are some examples of how you can use the Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 security appliances: • As a firewall: •...
  • Page 10: Package Contents

    Package Contents Package Contents The following figure shows the package contents for the Secure Firewall CSF-1230, CSF-1240, and CSF-1250. Note that the contents are subject to change, and your exact contents might contain additional or fewer items depending on what you ordered.
  • Page 11: Pullout Asset Tag And Compliance Label

    Figure 3: Pullout Asset Card on the Front Panel of the Chassis Pullout asset tab Label Digital Documentation Portal QR code Chassis serial number The following figure shows the location of the compliance label on the bottom of the chassis. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 12 Figure 4: Compliance Label on the Bottom of the Chassis Front panel (I/O side) Compliance label Bottom of the chassis — The following figure shows a sample compliance label found on the bottom of the chassis. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 13: Front Panel

    Front Panel Figure 5: Sample Compliance Label Front Panel The following figure shows the front panel of the Secure Firewall CSF-1230, CSF-1240, and CSF-1250. See Front Panel LEDs, on page 10 for descriptions of the front panel LEDs. Figure 6: Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Front Panel...
  • Page 14: Front Panel Leds

    SSD slot — Front Panel LEDs The following figure shows the LEDs on the front panel of the Secure Firewall CSF-1230, CSF-1240, and CSF-1250 and describes their states. Figure 7: Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Front Panel LEDs Management...
  • Page 15 • Green—Cloud disconnected. Note The LED pattern applies to zero-touch provisioning (ZTP). See the Easy Deployment Guide for Cisco Secure Firewall Threat Defense with Cisco Security Cloud Control for more information. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 16: Rear Panel

    SSD. Rear Panel The following figure shows the rear panel of the Secure Firewall CSF-1230, CSF-1240, and CSF-1250. See Ground the Chassis, on page 32for the procedure for attaching the grounding lug. Figure 8: Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Rear Panel...
  • Page 17: Hardware Specifications

    Overview Hardware Specifications Hardware Specifications The following table contains hardware specifications for the Secure Firewall CSF-1230, CSF-1240, and CSF-1250. Table 2: Hardware Specifications Specification CSF-1230 CSF-1240 CSF-1250 Dimensions (H x W x D) 1.72 x 11.22 x 17.25 inches (4.37 x 28.49 x 43.81 cm) 9.52 lb (4.31 kg)
  • Page 18 100 mm, may pose an eye hazard. Warning Statement 1057 Hazardous Radiation Exposure Use of controls, adjustments, or performance of procedures other than those specified may result in hazardous radiation exposure. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 19 Caution Although non-Cisco SFPs are allowed, we do not recommend using them because they have not been tested and validated by Cisco. Cisco TAC may refuse support for any interoperability problems that result from using an untested third-party SFP transceiver.
  • Page 20: Product Id Numbers

    Depending on fiber grade and core size, operating distance may vary. Product ID Numbers The following table lists the field-replaceable PIDs associated with the Secure Firewall CSF-1230, CSF-1240, and CSF-1250. The spare components are ones that you can order and replace yourself. If any internal components fail, you must get a return material authorization (RMA) for the entire chassis.
  • Page 21: Power Cord Specifications

    Orders delivered to Argentina, Brazil, and Japan must have the appropriate power cord ordered with the system. Note Only the approved power cords or jumper power cords provided with the chassis are supported. The following power cords are supported. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 22 Cord set rating: 10 A, 250 V Connector: V1625 — Figure 12: Brazil (CAB-C13-ACB) Plug: NBR 14136 Cord set rating: 10 A, 250 V Connector: EL 701B (EN 60320/C13) — Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 23 Figure 14: Europe (CAB-ACE) Plug: M2511 Cord set rating: 16 A, 250 V Connector: V1625 — Figure 15: India (CAB-IND-10A) Plug: IA16A3-C Cord set rating: 16 A, 250 V Connector: V1625BS-E — Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 24 Figure 17: Japan (CAB-C13-C14-2M-JP) PSE Mark IEC 60320-2-2/E Cord set rating: 10 A, 250 V Connector: IEC 60320/C13 — Figure 18: Japan (CAB-JPN-3PIN) Plug: M744 Cord set rating: 12 A, 125 V Connector: V1625 — Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 25 Figure 20: North America (CAB-AC) Plug: PS204 Cord set rating: 10 A, 250 V Connector: V1625 — Figure 21: Jumper (CAB-C13-C14-2M) IEC 60320/C14G Cord set rating: 10 A, 250 V Connector: IEC 60320/C13 — Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 26 Cord set rating: 10 A, 250 V Connector: V1625 — Figure 24: Taiwan (CAB-ACTW) Plug: EL 302 (CNS10917) Cord set rating: 10 A, 125 V Connector: EL 701 (EN 60320/C13) — Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 27 Overview Power Cord Specifications Figure 25: United Kingdom (CAB-ACU) Plug: 3P BS 1363 Cord set rating: 10 A, 250 V Connector: IEC 60320/C13 — Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 28 Overview Power Cord Specifications Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 29: Installation Preparation

    Installation Warnings Read the Regulatory and Compliance Information document before installing the chassis. Caution The Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 security appliances are for indoor use only. Take note of the following warnings: Warning Statement 1071 Warning Definition...
  • Page 30 Warning Statement 1051 Laser Radiation Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 31: Safety Recommendations

    Before working on a chassis, be sure the power cord is unplugged. Read the RCSI document before installing the chassis. Follow these guidelines when working on equipment powered by electricity: Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 32: Prevent Esd Damage

    If you are currently experiencing shutdowns or unusually high error rates with your existing equipment, these considerations may help you isolate the cause of failures and prevent future problems. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 33: Site Considerations

    • If your rack includes closing front and rear doors, the doors must have 65 percent open perforated area evenly distributed from top to bottom to permit adequate airflow. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 34 • Baffles can help to isolate exhaust air from intake air, which also helps to draw cooling air through the chassis. The best placement of the baffles depends on the airflow patterns in the rack. Experiment with different arrangements to position the baffles effectively. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 35: Rack-Mount The Chassis

    Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: • Invoice number of shipper (see the packing slip) • Model and serial number of the damaged unit • Description of damage Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 36: Ground The Chassis

    To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last. If your unit has modules, secure them with the provided screws. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 37 Prepare the other end of the grounding cable and connect it to an appropriate grounding point in your site to ensure adequate earth ground. What to do next Install the cables according to your default software configuration as described in the getting started guide. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 38 Figure 28: Attach the Rack-Mount Brackets to the Chassis Four 6-32 x 0.25-inch Phillips screws Rack-mount bracket Step 2 Attach the cable guides to the rack-mount brackets using the four 8-32 x 0.375-inch Phillips screws. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 39 We recommend that you install the chassis with the I/O side (rear panel) facing the cold aisle. Figure 30: Install the Chassis in the Rack Rack Rack-mount bracket Rack-mount screws — Chassis I/O side (rear panel) Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 40 Rack-Mount the Chassis Rack-Mount the Chassis What to do next You can now install the cables and power cord, as described in the getting started guide. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...
  • Page 41 Replace the SSD, on page 37 Replace the SSD The Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 ship with an SSD installed. You can replace this SSD should it fail. The SSD is not hot-swappable. Before replacing the SSD, you must power off the chassis by pressing the power switch on the rear panel.
  • Page 42 Step 4 Check the SSD LED to make sure the SSD is seated properly and functioning. See Front Panel LEDs, on page 10 for a description of the SSD LED. Cisco Secure Firewall CSF-1230, CSF-1240, and CSF-1250 Hardware Installation Guide...