Cisco CSC-C2FCIT Installing And Upgrading

Fddi card and appliques

Advertisement

Quick Links

Doc. No.
78-0946-08
Installing and Upgrading the
CSC-C2FCIT FDDI Card and Appliques
Product Numbers:
CSC-C2FCIT=
APP-LMM=
APP-LMS=
APP-LSM=
APP-LSS=
MC-C2FCIT-V10.3=
This publication provides instructions for installing the Fiber Distributed Data Interface (FDDI)
modules in the AGS+ router. These modules include the FDDI interface card with translational
bridging (CSC-C2FCIT) and the four available fiber-optic transceiver appliques, which provide
single-mode and/or multimode network interfaces. The C2FCIT card operates with the second-
generation ciscoBus card (CSC-CCTL2).
This publication also includes instructions for upgrading the C2FCIT microcode when required.
The sections following are included in this publication:
Note
operating correctly up until the time you performed this installation or upgrade, and that any
problems are a result of this procedure.
Copyright © 1994
Cisco Systems, Inc.
All rights reserved.
FDDI Module Overview, page 2
Installation Prerequisites, page 7
Installing Cards and Appliques, page 14
Testing the Installation, page 23
Upgrading Microcode, page 28
The procedures in the section "Testing the Installation" assume that your system has been
1

Advertisement

Table of Contents
loading

Summary of Contents for Cisco CSC-C2FCIT

  • Page 1 This publication provides instructions for installing the Fiber Distributed Data Interface (FDDI) modules in the AGS+ router. These modules include the FDDI interface card with translational bridging (CSC-C2FCIT) and the four available fiber-optic transceiver appliques, which provide single-mode and/or multimode network interfaces. The C2FCIT card operates with the second- generation ciscoBus card (CSC-CCTL2).
  • Page 2 FDDI Module Overview The FDDI interface modules described in this document include the single-port FDDI communications interface card with translational bridging (CSC-C2FCIT) and the four available fiber-optic transceiver appliques. While incorporating all of the functions of the C2FCI card, the C2FCIT card provides higher speeds than the C2FCI card as well as the following translational bridging capabilities: FDDI to FDDI (transparent), FDDI to Ethernet, and FDDI to Token Ring.
  • Page 3 Class A or Class B station. Class A is a dual attachment station (DAS) with primary and secondary rings; Class B is a single attachment station (SAS) with only a primary ring. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 4 Figure 2 Multimode/Multimode—APP-LMM PHY-A RING A ENDEC RING B Cables to FDDI controller card PHY-B LEDs ENDEC 16-pin DIN connector Faceplate Component side view 4 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 5 ENDEC Cables to FDDI controller card PHY-B LEDs ENDEC Faceplate Component side view Figure 4 Single Mode/Multimode—APP-LSM PHY-A ENDEC Cables to FDDI controller card PHY-B ENDEC LEDs Faceplate Component side view Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 6 Invisible laser radiation may be emitted from the aperture ports of the single-mode FDDI Warning products when no fiber cable is connected. Avoid exposure and do not stare into open apertures. This product meets the Class 1 Laser Emission Requirement from CDRH FDDI. 6 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 7: Installation Prerequisites

    Invisible laser radiation may be emitted from the aperture ports of the single-mode appliques when no fiber cable is connected. Avoid exposure and do not stare into open apertures. This product meets the Class 1 Laser Emission Requirement from CDRH FDDI. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 8: System Compatibility

    Having the power cord connected will ensure a ground path for any ESD voltages. • Always use an ESD-preventive wrist strap or ankle strap and ensure that it makes good skin contact. 8 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 9 The AGS+ uses a slot priority scheme that assigns a priority to each ciscoBus card according to the ciscoBus slot in which the card resides. The card in ciscoBus slot 0 receives the highest ciscoBus priority, while the card in ciscoBus slot 3 receives the lowest ciscoBus priority. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 10 Follow with the CSC-FCI and C2FCI cards. Next, install CSC-C2FCIT cards. Last, install the CSC-HSCI and C2HSCI cards with the APP-ULA (UltraNet) applique. Always install cards in the lowest-numbered available slot. For example, if you are using only CSC-C2HSCI cards (with APP-ULA), place the first in slot 0, the second in slot 1, and so forth.
  • Page 11 1. The designator C2 in parentheses indicates that the card has Microcode Version 10.0 or later installed. The designator C2 not in parentheses indicates that the card ships with Microcode Version 10.0 or later by default. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 12 Determine the available power budget, subtract that sum from 300W (260W for chassis shipped before 10/1/91); the result is the power budget available for new cards. 12 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 13 Installation Prerequisites The following example shows how to determine if you can add two new CSC-C2FCIT cards to an AGS+ (with all values in watts): One CSC-ENVM card 1 x 10 = 10 One CSC/4 processor card 1 x 35 = 35...
  • Page 14: Setup Command Facility

    If you are removing the front panel for the first time, use the medium flat-blade screwdriver to turn the thumbscrews counterclockwise to loosen them. When you replace the panel, turn the thumbscrews clockwise until they are finger-tight. 14 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 15 You will have to use a moderate amount of force to push the card into the slot properly. Before Note pushing the card into the slot, ensure that the card is aligned with the ciscoBus and Multibus slots and that the chassis is firmly mounted on a stable surface. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 16 Remove the top cover of the applique card cage by loosening the four cover fasteners that Step 3 secure it. (See Figure 10.) 16 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 17 The guide pins should pass through the alignment holes in the tabs on the top of each applique and faceplate assembly. Secure the top cover to the card cage with the four cover fasteners. (See Figure 10.) Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 18 Secure the card cage with the connector plate screws you removed earlier, leaving Step 3 appropriate holes empty for the ground straps. See Figure 12 and Figure 13 for ground strap configurations. 18 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 19 Secure the ground strap with the two Phillips screws. Step 3 Connect ground straps to other appliques as necessary, and proceed to the section, Step 4 “Connecting Internal and External Cables” on page 20. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 20 The C2FCIT card connectors are shown in Figure 14, and the ribbon cable connectors are listed in Table 4. The ribbon cable orientation and labeling for the FDDI applique is shown in Figure 15. 20 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 21 FDDI C, G, K, or O FDDI D, H, L, or P FDDI D, H, L, or P Figure 14 Orientation of the FDDI Connectors on the CSC-C2FCIT Card Microcode EPROM FDDI A, E, I, M FDDI B, F, J, N FDDI C, G, K, O...
  • Page 22 Optical Bypass Switch Pinout Pin No. Description +5V to secondary switch +5V to primary switch Ground to enable primary switch Ground to enable secondary switch Sense circuit—1 kohm to +5V Ground—sense circuit return 22 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 23: Testing The Installation

    EXEC show commands to verify that your interfaces are recognized and have been assigned port (unit) addresses by the system. Note In order to test the microcode EPROM installation, the following sections discuss the LED functions and show commands in depth. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 24: Reading The Led Indicators

    Multibus backplanes. When the card is installed correctly, the ejector levers are firmly in place. Figure 16 CCTL2 Card LED Indicators—Front-Edge View Green 3 2 1 0 ciscoBus slot indicators LEDs 24 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 25 Unused (green) Unused (yellow) Unused (yellow) PHY A LED 0 PHY A LED 1 PHY A LED 2 PHY B LED 0 PHY B LED 1 PHY B LED 2 Faceplate Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 26 The EXEC command show controller cbus displays the current internal status of the ciscoBus card, as well as the status of all other ciscoBus cards being used (including the C2FCIT). 26 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 27 Some aspect of the hardware is not functioning properly if the line protocol is down (in the first line of the above sample output). Ensure that the network interface is properly connected and terminated. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 28: Restarting The System

    This procedure is required only if you need to change or upgrade the microcode EPROM device on your CSC-C2FCIT card from Microcode Versions 10.0 (the initial release), 10.1, or 10.2 to Version 10.3. Microcode Version 10.3 requires Software Release 9.1(1) or later.
  • Page 29: Tools And Parts Required

    Remove the C2FCIT card from the card cage slot and place it on an antistatic mat or Step 7 antistatic foam in the orientation shown in Figure 18. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 30: Replacing Components

    Align the notch on the new serial PROM (Part Number 17-0878-04) with the notch in the U34 socket. Ensure that the pins are aligned with the socket, then insert the new component. 30 Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 31 Aarm: 0000 Barm: 1388 fint: 9078 For descriptions of additional commands and examples, refer to the Router Products Configuration Guide publication. If you have any problems, contact a customer service representative. Installing and Upgrading the CSC-C2FCIT FDDI Card and Appliques...
  • Page 32: Cisco Information Online

    SMARTnet, SynchroniCD, The Packet, UniverCD, Workgroup Director, and Workgroup Stack are trademarks; Access by Cisco and Bringing the power of internetworking to everyone are service marks; and Cisco, Cisco Systems, and the Cisco logo are registered trademarks of Cisco Systems, Inc. All other trademarks, service marks, registered trademarks, or registered service marks mentioned in this document are the property of their respective owners.

This manual is also suitable for:

App-lmmApp-lmsApp-lsmApp-lssMc-c2fcit-v10.3

Table of Contents