Download Print this page

SMC Networks EX600-TDX1 Operation Manual page 18

Fieldbus system terminal unit (io-link input unit)

Advertisement

3.4. ISDU: Vendor definition parameters
Index (dec)
Subindex Access
0x0040 (64)
1 to 32
0x0041 (65)
1 to 32
0x0042 (66)
1 to 32
0x0043 (67)
1 to 48
0x0044 (68)
1 to 5
...
...
0x0053 (83)
1 to 5
0x0055 (85)
1 to 32
0x0056 (86)
1 to 32
0x0057 (87)
1 to 32
0x0058 (88)
1 to 32
0x0091 (145)
1 to 32
0x0092 (146)
0
0x0093 (147)
1 to 16
Index (dec)
Subindex Access
0x0040 (64)
1 to 16
0x0041 (65)
1 to 16
0x0042 (66)
1 to 16
0x0043 (67)
1 to 24
0x0044 (68)
1 to 5
...
...
0x004B (75)
1 to 5
0x0055 (85)
1 to 16
0x0056 (86)
1 to 16
0x0057 (87)
1 to 16
0x0058 (88)
1 to 16
0x0091 (145)
1 to 16
0x0092 (146)
0
0x0093 (147)
1 to 8
Note
• "Y" indicates that the corresponding item is included in Data Storage, and "N" indicates that the
corresponding item is not included in Data Storage.
• Hereinafter, the input No. at the xth point is represented as "INx." (x = 0 to 32, or 0 to 16)
Table 3-7. Vendor definition parameters (EX600-TDX1)
Parameter name
R/W
Input filtering time
R/W
Input extension time
R/W
Input counter limit value
R/W
Accumulated flow setting
R/W
Auto switch failure diagnosis setting CH0
...
...
R/W
Auto switch failure diagnosis setting CH15
R
Input counter
R
Input count over state
R
Accumulated flow display
R
Auto switch failure state
R/W
Input count reset
W
Input count batch reset
R/W
Accumulated flow display reset
Table 3-8. Vendor definition parameters (EX600-TDX2)
Parameter name
R/W
Input filtering time
R/W
Input extension time
R/W
Input counter limit value
R/W
Accumulated flow setting
R/W
Auto switch failure diagnosis setting CH0
...
...
R/W
Auto switch failure diagnosis setting CH7
R
Input counter
R
Input count over state
R
Accumulated flow display
R
Auto switch failure state
R/W
Input count reset
W
Input count batch reset
R/W
Accumulated flow display reset
Size [byte] DataStorage
1
1
4
1
1 or 10
(14 in total)
...
1 or 10
(14 in total)
4
1
2
2 or 15
(19 in total)
1
1
1
Size [byte] DataStorage
1
1
4
1
1 or 10
(14 in total)
...
1 or 10
(14 in total)
4
1
2
2 or 15
(19 in total)
1
1
1
-18-
Reference
Y
Section 3.4.1
Y
Section 3.4.2
Y
Section 3.4.3
Y
Section 3.4.4
Y
...
Section 3.4.5
Y
N
Section 3.4.6
N
Section 3.4.7
N
Section 3.4.8
N
Section 3.4.9
N
Section 3.4.10
N
Section 3.4.11
N
Section 3.4.12
Reference
Y
Section 3.4.1
Y
Section 3.4.2
Y
Section 3.4.3
Y
Section 3.4.4
Y
...
Section 3.4.5
Y
N
Section 3.4.6
N
Section 3.4.7
N
Section 3.4.8
N
Section 3.4.9
N
Section 3.4.10
N
Section 3.4.11
N
Section 3.4.12
No.DOC1113170-1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EX600-TDX1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ex600-tdx2