1. Safety Instructions

These safety instructions are intended to prevent hazardous situations
and/or equipment damage.
These instructions indicate the level of potential hazard by label of
"DANGER", "WARNING"or "CAUTION", followed by important safety
information which must be carefully followed.
To ensure safety of personnel and equipment the safety instructions in
this manual and the product catalogue must be observed, along with
other relevant safety practices.
In extreme conditions, there is a possible result
DANGER
of serious injury or loss of life.
If instructions are not followed there is a
WARNING
possibility of serious injury or loss of life.
If instructions are not followed there is a
CAUTION
possibility of injury or equipment damage.
WARNING
Do not disassemble, modify (including change of printed circuit
board) or repair this product.
Injury or failure can result.
Do not operate the device with wet hands.
There is a risk of electric shock.
Do not operate the product beyond the specification range.
Do not use the product for flammable or harmful gases or liquids.
Fire, malfunction, or damage to the product can result.
Please confirm the specifications before use.
Do not operate the product in an environment where flammable
or explosive gases may be present.
Fire or an explosion can result.
This product is not designed to be explosion proof.
The following instructions must be followed during maintenance:
• Turn off the power supply.
• Stop the air supply, exhaust the residual pressure and make sure that
the air is released to atmosphere before performing maintenance.
Otherwise injury can result.
Do not apply pressure to the LCD display.
This may cause damage or injury.
The forced input/output function is used to change the signal
status forcibly.
When operating this function, be sure to check the safety of the
surroundings and the installation.
Otherwise injury or equipment damage could result.
Erroneous parameter setting can result in malfunction.
Be sure to confirm the settings.
Otherwise injury or equipment damage could result.
1. Safety Instructions
(continued)
CAUTION
Perform a proper functional check after completing maintenance.
Stop operation if the equipment does not function properly.
Safety cannot be assured due to unexpected malfunction.
Switching the HOLD/ CLEAR function selection mode, will switch
the operation of the input / output signal and emergency stop, so
pay due attention to safety when setting.
There is a risk of injury and equipment damage.
When setting the parameters to the factory defaults, unpredictable
operation of connected equipment may occur.
It is essential to carry out this operation paying attention to safety.
Otherwise injury or equipment damage could result.

2. How to Order

Refer to the catalogue or operation manual for this product.

3. Specifications

Refer to the catalogue or operation manual for this product.

4. Outline dimensions(mm)

Refer to the catalogue or operation manual for this product.

5. Names / Functions of individual Parts

1
3
2
10
9
8
7
6
No.
Name
Description
Displays the operation items and information
1
LCD display
about the unit.
2
Connector
Connector for Handheld Terminal cable.
Handheld Terminal
Cable to connect the SI Unit to the Handheld
3
cable
Terminal.
In selecting screen, this button is used for
ENTER button
selecting the required item. In setting screen,
4
(
)
pressing this button registers the selected
contents.
This button is used to move the cursor in LCD
Cursor move
display upward/downward and right/left
5
button
direction. Select the required item using this
(
, ,
,
)
button. Use this button to increase/decrease or
turn ON/OFF the setting value.
6
F2 button (
)
This button functions according to the indication
or instruction displayed on the screen.
7
F1 button (
)
In selecting screen, this button is used to return
Escape button
8
to the previous screen. Pressing this button
(
)
cancels the setting contents.
The Error LED (Red) turns ON when EX600
diagnostics error occurs. (Refer to the
9
Error LED
"Troubleshooting" and "Error Code" section for
further details.)
The Power LED (Green) turns ON when the
Handheld Terminal is connected with an EX600
10 Power LED
SI Unit and power supply for Control/Input is
ON.
<Wiring Method
(connecting Handheld Terminal connector)
When inserting the connector into the Handheld Terminal, insert
the connector straight in until it clicks into place.
<Wiring Method (connecting to the SI Unit)>
The M12 cable connector is connected to the "connector for
4
Handheld Terminal" on the SI Unit. The method of connecting
the cable to the SI Unit is explained in the "<SPEEDCON Wiring
method>" section.
5
<SPEEDCON Wiring method>
Set the projected portion of the cable connector metal ring (plug /
socket) to the mark at cable end.
Push the connector straight to insert it into the receptacle of the unit.
If inserted without aligning the mark, the connector will not mate with
the receptacle.
Mark at cable end
Projected
portion
Mark on the unit
>

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX600-HT1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks EX600-HT1

  • Page 1 Stop operation if the equipment does not function properly. Fieldbus System - Handheld terminal Safety cannot be assured due to unexpected malfunction. Type EX600-HT1 Switching the HOLD/ CLEAR function selection mode, will switch 1. Safety Instructions the operation of the input / output signal and emergency stop, so These safety instructions are intended to prevent hazardous situations pay due attention to safety when setting.
  • Page 2 EX600-TFM07GB 8.Trouble Shooting 6. Wiring 7. Setting (continued) (continued) Turn the connector clockwise. It stops when turned 1/4 turn.Turn it Indication Problem Investigation method Counter-measure Main Menu further. When the connector is turned 1/2 turn from the original posi- <Main Menu> 1.I/O monitor tion, the projected portion is set at the diagonal position to the mark Power LED...

Table of Contents