1. SAFETY GUIDELINES
1.1
Basic guidelines
The CENT-D control unit is delivered in a condition allowing for
safe installation and operation, provided that all guidelines herein
as well as safety and accident prevention regulations relevant for
the given application (e.g. gate or roller blind) are observed.
Only qualified and licenced personnel is allowed to install and
repair electrical devices. It is prohibited to make any changes or
modifications to the device. Warranty repairs may be conducted
only by the manufacturer. Use only original spare parts and
accessories during post-warranty repairs. Operational safety of
the CENT-D control unit can only be ensured if it is used for its
intended purpose. Do not exceed limit values given in technical
information.
1.2
Additional safety regulations
Observe relevant safety and accident prevention regulations
when installing, commissioning and maintaining the control unit.
The following must be given special consideration:
1. Fire safety regulations.
2. Accident prevention regulations.
1.3
General notes on risks and safety measures
These notes are general guidelines for the use of INEL controllers
in combination with other devices. These guidelines must be
strictly observed when installing and operating the devices.
Warning - against possible damage to the control
units or other tangible assets if no relevant safety
measures are taken:
• Before installing the control unit, check the mounting of all drives
and other devices connected to the system.
Danger - means that there is a threat to life and
limb of the user if no relevant safety measures are
taken:
kmk
Operating instructions
CENT-D Universal control unit with sequential codes
• Observe applicable safety and accident prevention regulations
• Before replacing any fuses, disconnect any power cables, then
replace the fuse and reconnect the cables.
• For INEL devices with permanent power connection to the
controller, in addition to fuse protection use an isolation switch
allowing for safe power supply disconnection (e.g. fuse cut-off
switch) installed in such a way that all connections can easily be
cut out.
• Inspect power wires and cables regularly for damaged insulation
and conductor continuity.
• If any damage is identified, cut off power immediately and
replace the damaged wiring.
• Check the compatibility of the permissible voltage of the device
with the local power supply before connecting.
1.4
• Do not allow children to play with control devices.
• Keep the remote control out of reach of children.
• Observe the moving device (e.g. gate, roller blind) and keep
people away until it fully opens or closes.
• The users of the control unit must be instructed in its operation
and existing risks related to its usage. Persons are deemed to
have been trained if the employer, administrator or owner allowed
them to use the device and instructed them in its operation.
2. TECHNICAL SPECIFICATIONS
Housing
Supply voltage
Operating frequency
Operating temperature range
Storage temperature range
Humidity
Output relays
Output fuses
Output current
Terminals
Mass
Dimensions
3.
ELECTRICAL CONNECTIONS
DISCONNECT POWER SUPPLY BEFORE
MAKING ANY CONNECTIONS!
Incorrect installation will cause the device to
work improperly or damage it.
Warning
Polymer plastic
230V AC, 50Hz
433.92MHz
-5°C - +45°C
-25°C - +70°C
up to 93%
10A / 250V AC
3.15A / 250V AC
Rated 3A
Screw
450g
112 x 73 x 45 mm