Summary of Contents for Veichi AC600 Series

  • Page 1 Manual AC600 Series AC Drive...
  • Page 2 Optional accessories are available to achieve IP54 protection. The AC600 series drive is suitable for driving equipment across various industries, including oil and gas, metallurgy, textiles, papermaking, wire drawing, machine tools, packaging, food processing, fans, pumps, and other automated production systems.
  • Page 3: Table Of Contents

    Catalog AC600 Series AC Drive Manual Catalog 1 General ....................................1 1.1 Safety Precautions ............................... 1 1.2 Pre-use ................................. 3 1.3 Technical Specifications ............................4 1.4 CE Standard .................................7 2 Installation ..................................8 2.1 Safety Precautions ............................... 8 2.2 Environment ................................ 9 2.3 Installation Direction and Space ........................11...
  • Page 4 Catalog AC600 Series AC Drive Manual F05.0x: Terminal Function ..........................58 F05.1x-F05.2x: Terminal Operation Control ....................59 F05.3x: PUL Terminal ............................. 60 F05.4x: vX Terminal ............................60 4.9 F06: DO Terminal ..............................61 F06.0x: Terminal Operation ..........................61 F06.1x: Terminal Delay ...........................61 F06.3x~F06.5x: vY Terminal ..........................
  • Page 5 Catalog AC600 Series AC Drive Manual F25.24~F25.35: AO1 Correction ........................97 F25.36~F25.47: AO2 Correction ........................98 4.21 A00: Default Parameters ..........................99 4.22 d00: Motor Parameters ..........................101 d00.0x: Motor Control ...........................101 4.23 d01: Motor 2 Parameters ..........................101 d01.0x: Basic Parameters and Auto-tuning ....................101 d01.1x: AM Parameters ..........................
  • Page 6 Catalog AC600 Series AC Drive Manual d09.1x: User-defined V/F Curve ........................141 d09.2x: VF-SPLIT Control ..........................142 d09.3x: V/F ECO Control ..........................143 d09.4x: V/F PM Anti-oscillation ........................143 d09.5x: V/F PM Flux Control ........................143 d09.6x: V/F PM Current Control ........................144 4.32 E00: IO Extension Input ..........................145...
  • Page 7: Catalog

    Catalog AC600 Series AC Drive Manual 5.1 Inspection .................................210 5.2 Maintenance ..............................212 5.3 Product Warranty ............................. 212 6 STO Function ................................213 6.1 Standards ................................. 213 6.2 Installation ............................... 213 6.2.1 Terminal Distribution and Definition ....................213 6.2.2 Electrical Specifications and Connection .................... 214 6.3 Commissioning and O&M Requirements .......................216...
  • Page 8: General

    Please pay attention to all information in this manual regarding safety. Failure to observe them may result in death or serious injuries. VEICHI will not be held liable for injuries and equipment damage caused by your company or your customers' failure to comply with the contents of this manual.
  • Page 9 1 General AC600 Series AC Drive Manual WARNING For mechanical safety After the wiring work and parameter setting are completed, be sure to perform a test run to make sure that the  AC drive can operate safely; otherwise, it may cause personal injury or equipment damage.
  • Page 10: Pre-Use

    If everything is fine, please double-check that the model number of the received drive is the same as the order sheet. Model and nameplate: Table 1-1 Nameplate and Naming Rules of AC600 Series Drive Name Description Product series AC600 series drive ①...
  • Page 11: Technical Specifications

    1 General AC600 Series AC Drive Manual 1.3 Technical Specifications Three-phase 380V voltage  Table 1-2 (380V) (V1~V4) Dimension Power(kW) 0.75 18.5 Applicable G-type 0.75 18.5 motor P-type 18.5 capacity (kW) G-type Rated output current (A) P-type Output Voltage 3-phase 0V~input voltage...
  • Page 12 1 General AC600 Series AC Drive Manual Table 1-4 (380V) (V10~V11) Dimension Power (kW) Applicable G-type motor P-type capacity (kW) G-type Rated output current (A) P-type 1100 Output Output voltage 3-phase 0V~input voltage Output frequency 0Hz~599Hz Carrier frequency 1.0kHz~16kHz (automatically adjustable based on load characteristics) G-type: 150% rated current for 90s;...
  • Page 13 1 General AC600 Series AC Drive Manual 4 patterns: Linear torque characteristic curve, self-defined V/F curve, torque drop V/F curve characteristic curve (1.1~1.9 power), and square V/F curve 2 patterns: Linear and S-curve acceleration/deceleration Four sets of acceleration and deceleration times, the default time unit is 0.01s, and the ACC/DEC curve corresponding maximum time can be set to 650.00s.
  • Page 14: Ce Standard

    1 General AC600 Series AC Drive Manual -10℃~+40℃, derating is required between 40℃~+50℃ Operating IP20: 40℃~50℃, derate 1.5% for every 1℃ rise temperature IP54: 40℃~50℃, derate 2.5% for every 1℃ rise Humidity 5%RH~95%RH, no condensation Vibration 5.9m/s² (0.6g) at 9Hz~200Hz Storage temperature -30℃~+60℃, with air temperature change <1℃/min...
  • Page 15: Installation

    2 Installation AC600 Series AC Drive Manual 2 Installation 2.1 Safety Precautions This section explains the various precautions that must be followed to ensure safe use, maximized performance, and reliable operation of the AC drive. Cautions on use of AC drive When installing the AC drive in a closed cabinet, please configure a cooling fan or cooling air conditioner for full cooling.
  • Page 16: Environment

    2 Installation AC600 Series AC Drive Manual Cautions on grounding Ignoring these precautions may result in personal injury and death, increased electromagnetic interference, and equipment damage. Always ground the drive, motor, and connected equipment to ensure safety and reduce ...
  • Page 17 2 Installation AC600 Series AC Drive Manual Figure 2-1 IP20 Temperature Derating Curve IP54: In the temperature range of 40°C to 50°C, the rated output current must be derated by 2.5% for each 1°C increase. The output current can be calculated by multiplying the rated value by the derating factor (k): Figure 2-2 IP54 Temperature Derating Curve ...
  • Page 18: Installation Direction And Space

    2 Installation AC600 Series AC Drive Manual  After exceeding the allowable input voltage, the AC drive shall be derated as shown in the following figure. Model Three-phase AC 400V drive Input voltage 380V to 480VAC (tolerance: -15% to +10%), 47Hz to 63Hz Current derating at high input voltage: Output current is derated by 20% for every 100V increase in input voltage.
  • Page 19: Overall Dimensions

    2 Installation AC600 Series AC Drive Manual 2.4 Overall Dimensions IP20 Overall Dimensions Overall dimensions of the AC drive V1~V3 (plastic)  Figure 2-4 V1~V3 Overall Dimensions and Hole Size Table 2-1 V1~V3 Overall Dimensions and Hole Size Outer Dimension (mm)
  • Page 20 2 Installation AC600 Series AC Drive Manual Overall dimensions of the AC drive V6~V11 (steel)  Aperture Figure 2-6 V6~V11 Overall Dimensions and Hole Size Table 2-3 V6~V11 Overall Dimensions and Hole Size Outer Dimension (mm) Hole Size (mm) Type...
  • Page 21 2 Installation AC600 Series AC Drive Manual Table 2-4 V1~V3 Junction Box Overall Dimensions and Hole Size Outer Dimension (mm) Hole Size (mm) Aperture Type Model (mm) AC600-T4-R75G/1R5P-*V* AC600-T4-1R5G/2R2P-*V* AC600-T4-2R2G/004P-*V* 116.5 336.5 211.5 148.5 16.5 4-M4 AC600-T4-004G/5R5P-*V* AC600-T4-5R5G/7R5P-*V* AC600-T4-7R5G/011P-*V* 123.5 364.5...
  • Page 22 2 Installation AC600 Series AC Drive Manual Table 2-6 V1~V3 Wall-through Drive Overall Dimensions and Hole Size Outer Dimension (mm) Hole Size (mm) Aperture Type Model (mm) AC600-T4-R75G/1R5P-* AC600-T4-1R5G/2R2P-* AC600-T4-2R2G-* 185.4 356.4 211.5 102.5 159.4 38.2 10.2 4-M4 AC600-T4-004G/5R5P-* AC600-T4-5R5G-* AC600-T4-7R5G/011P-* 202.4...
  • Page 23 2 Installation AC600 Series AC Drive Manual Diagram of optional EMC filter and grounding clip  EMC filter EMC grounding clip Diagram of control terminal grounding  Control terminal grounding clip...
  • Page 24 2 Installation AC600 Series AC Drive Manual Diagram of wall-through installation (example with 5.5)  1 . S ecure the up per and low er 2 . S ecure the flange b rackets o f the flange m ounting m oun tin g b racket tightly...
  • Page 25 2 Installation AC600 Series AC Drive Manual Keypad and opening dimensions Boundary dimension and bore dimension of external dual-line keypad (unit: mm)  15.4 17.5 Use self-tapping 17.5 screws ST3.5*6 Keypad opening dimensions 50.0000±0.0100 34.6 Boundary dimension and bore dimension of external dual-line keypad cover (unit: Mm) ...
  • Page 26: Standard Wiring

    AC drive (+24V terminal) or external power supply (PLC terminal). 2.5.2 STO Safety Torque Off (STO) is a safety function in accordance with IEC 61800-5-2: 2016. The AC600 series offers STO options. STO disables the PWM signal of the drive to close the output of the power devices and cut off the motor torque, then the motor safely enter a torque-free state to avoid accidental start-up.
  • Page 27 2 Installation AC600 Series AC Drive Manual Input signals to STO1 and STO2 terminal must both be active (STO shorted to 24V) to enable normal operation of the motor. The STO board has four PIN terminals, namely STO1, STO2, + 24V and COM, and has one SPI extension port,...
  • Page 28: Illustration And Description Of Dip Switch

    2 Installation AC600 Series AC Drive Manual 2.5.3 Illustration and Description of DIP Switch Illustration Description 485 terminating RS485 dialed to ON, and then communication circuit is resistor connected to a 120Ω terminating resistor 0.0kHz~100.0kHz frequency output from AO interface...
  • Page 29: Multi-Function Input Connection

    2 Installation AC600 Series AC Drive Manual 2.5.4 Multi-function Input Connection Wiring method of PNP transistor: Internal 24V power Drive Drive External 24V power supply supply External 24Vpower Jump cap Jump cap +24V +24V supply +24V +24V Shielded wire Shielded wire...
  • Page 30: Wiring Of Main Circuit

    2 Installation AC600 Series AC Drive Manual 2.6 Wiring of Main Circuit 2.6.1 Wiring of Main Circuit 2.6.2 Arrangement and Definition of Main Circuit Terminals...
  • Page 31 Input-side EMC grounding terminal (disconnectable ground) ● Connection of braking resistor for drives below 37kW (inclusive): Figure 2-11 Connection of Braking Resistor for AC600 Series Drives below 37kW (Inclusive) ● Connection of braking resistor for drives of 45kW~75kW: Dynamic Brake Unit...
  • Page 32 If a built-in braking unit is present, no external connection is required. If connecting an external braking unit, select the braking resistor based on both the external unit and the drive's limitations. For specifications or inquiries, contact the Customer Service Department of Suzhou Veichi Electric Co., Ltd. if needed. ● Recommended brake resistor The braking resistor value and resistance power described in the following table are verified according to the common inertia load and intermittent braking mode.
  • Page 33 Motor Power (kW) Min. Resistance (Ω) AC600-T4-R75G/1R5P-* 0.75 AC600-T4-1R5G/2R2P-* 1.50 AC600-T4-2R2G/004P-* AC600-T4-004G/5R5P-* AC600-T4-5R5G/7R5G-* AC600-T4-7R5G/011P-* AC600-T4-011G/015P-* 11.0 AC600-T4-015G/018P-* 15.0 AC600-T4-018G/022P-* 18.5 AC600-T4-022G/030P-* 22.0 Note: The -* indicates derivative models of the AC600 series, which can be chosen by consulting the table above.
  • Page 34: Recommended Main Circuit Components Specification

    2 Installation AC600 Series AC Drive Manual 2.6.3 Recommended Main Circuit Components Specification Contactor Breaker Fuse Model Specs Specs Specs Fuse Model Input Reactor Sine Wave Filter AC600-T4-R75G-* KTK-10 VC-ACL-C-03P7A-T3-2M24 JL-SWF-4-004 AC600-T4-1R5G-* KTK-10 VC-ACL-C-03P7A-T3-2M24 JL-SWF-4-004 AC600-T4-2R2G-* KTK-15 VC-ACL-C-05P5A-T3-2M18 JL-SWF-4-008 AC600-T4-004G-*...
  • Page 35: Wiring Of Control Circuit

    AC600-T4-560G-* 1200 2000 VC-ACL-A-1250A-T3-11U6 JL-SWF-4-1200 2.7 Wiring of Control Circuit 2.7.1 Arrangement of Control Circuit Terminals Table 2-11 Arrangement and Definition of AC600 Series Control Circuit Terminals Type Mark Name Description Provide +10V power supply with maximum output current External...
  • Page 36: Control Circuit Wiring Specification

    2 Installation AC600 Series AC Drive Manual STO 24V power supply STO1 terminal Connected to an external power supply or to the onboard Termin STO 24V power supply +24V power supply. STO2 terminal 1. Range: DC 0V~10V/0mA~20mA AI1-GND Voltage/current AI 2.
  • Page 37: Keypad Layout And Operation Instructions

    3 Keypad Layout and Operation Instructions AC600 Series AC Drive Manual 3 Keypad Layout and Operation Instructions Keypad description Figure 3-1 Keypad Description Table 3-1 Indicator Description Region Icon Name Description Slave station indicator Displays different slave stations Fault indicator...
  • Page 38 3 Keypad Layout and Operation Instructions AC600 Series AC Drive Manual Indicates parameter units; no unit lights if not among the 9 units Unit indicator listed. Short press: Return/Cancel; Long press: Enter Monitor C parameter interface Multi-function key Short press to activate...
  • Page 39 3 Keypad Layout and Operation Instructions AC600 Series AC Drive Manual All indicators in Self-test interface on. Description Set the basic parameters  Take F01.22 [ACC Time 1]= 10.00s as an example. Note To modify the tens-, hundreds- and thousands-bit of a parameter, press Left/Right for quick positioning.
  • Page 40: Parameter And Function Code Description

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4 Parameter and Function Code Description 4.1 Terms and Marks Marks and terms of control modes  Mark Description Valid parameters under AM V/F control. Valid parameters under AM open-loop vector control.
  • Page 41 4 Parameter and Function Code Description AC600 Series AC Drive Manual F06.0x Terminal Operation F06 DO Terminal F06.1x Terminal Delay F06.3x-4x vY Terminal F07.0x Type F07.1x Line Setting F07 AI Terminal F07.2x Curve 1 Setting F07.3x Curve 2 Setting F07.4x AI as XI F08.0x...
  • Page 42 4 Parameter and Function Code Description AC600 Series AC Drive Manual F25.36~F25.47 AO2 Correction A00 Default Parameters A00.00~A00.40 User-Defined Address d00 Motor Parameters d00.0x Motor Control d01.0x Basic Parameters and Auto-tuning d01.1x AM Parameters d01 Motor 2 Parameters d01.2x~d01.5x PM Parameters d01.6x-d01.7x...
  • Page 43 4 Parameter and Function Code Description AC600 Series AC Drive Manual d09.0x V/F Control d09.1x User-defined V/F Curves d09.2x VF-SPLIT Control d09 Motor 4 V/F Control d09.3x V/F ECO Control d09.4x V/F PM Anti-oscillation d09.5x V/F PM Flux Control d09.6x- d09.8x V/F PM Current Control E00.0x...
  • Page 44: F00: Environmental Settings

    4 Parameter and Function Code Description AC600 Series AC Drive Manual C02.xx Error Record 2 C03.xx Operation Monitoring C04.xx System Monitoring 4.3 F00: Environmental Settings F00.0x: Environment Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC...
  • Page 45: F00.1X: System

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F00.1x: System Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Ones-bit: Macro mode 0: General 1: Fan, pump 2: Machine tool 3: Punching machine 0x0000 F00.10...
  • Page 46: F01: Basic Command Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.4 F01: Basic Command Parameters F01.0x: Basic Commands Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Set the motor control mode. 0: AM-V/F Motor 1 1: AM-SVC F01.00...
  • Page 47: F01.1X: Frequency Range

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4: Max. (A or B) 5: Min. (A or B) V/F SVC FVC PMV/F PMSVC PMFVC Bind each command source to frequency sources when this parameter is valid. Ones-bit: Bind via keypad...
  • Page 48: F01.2X~F01.3X: Acc/Dec Time

    4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC Set the frequency command resolution. Frequency F01.14 0: 0.01Hz Command STOP (0x010E) 1: 0.1Hz (0~3) Resolution 2: 0.1r/min 3: 1r/min F01.2x~F01.3x: ACC/DEC Time...
  • Page 49: F01.4X: Pwm

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Start Time V/F SVC FVC PMV/F PMSVC PMFVC F01.32 0.20s S-Curve (0x0120) Set the end time of s-curve acceleration. (0.00s~10.00s) End Time V/F SVC FVC PMV/F PMSVC PMFVC F01.33 0.20s...
  • Page 50: F02: Motor 1

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 30ms F01.45 V/F SVC FVC PMV/F PMSVC PMFVC Protection (0ms~ STOP (0x012D) Set the bootstrap protection time Time 60000ms) V/F SVC FVC PMV/F PMSVC PMFVC F01.46 Random The larger this setting, the greater the carrier...
  • Page 51: F02.1X: Am Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0206) Current Set the rated current of the motor. (0.1A ~ 3000.0A) V/F SVC FVC PMV/F PMSVC PMFVC After the parameter auto-tuning is finished, [F02.07] will be set to "0" automatically.
  • Page 52: F02.2X: Pm Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0x0000 F02.19 Parameter V/F SVC FVC PMV/F PMSVC PMFVC (0x0000~ STOP (0x0213) Range Set the parameter range. 0xFFFF) F02.2x: PM Parameters Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Up to model F02.20...
  • Page 53: F02.4X~F02.5X: Pm D/Q-Axis Inductance Saturation Coefficient

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F02.4x~F02.5x: PM D/Q-Axis Inductance Saturation Coefficient Code Default Name Content Property (Address) (Range) D-Axis V/F SVC FVC PMV/F PMSVC PMFVC 100.0% F02.40 Inductance Set the D-axis inductance saturation coefficient 0 for (0.1%~...
  • Page 54: F02.6X~ F02.7X: Tuning Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Coefficient 3 Q-Axis V/F SVC FVC PMV/F PMSVC PMFVC 100.0% F02.54 Inductance Set the Q-axis inductance saturation coefficient 4 for (0.1%~ (0x0236) Saturation permanent magnet synchronous motors. 2000.0%) Coefficient 4...
  • Page 55: F03: Vector Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Deadtime F02.70 V/F SVC FVC PMV/F PMSVC PMFVC Compensatio (0x0246) Set the deadtime compensation gain. (0~65535) n Gain F02.71 Actual V/F SVC FVC PMV/F PMSVC PMFVC 0.00 (0x0247) Deadtime Set the actual value of deadtime.
  • Page 56: F03.1X: Acr (Automatic Current Regulator) And Torque Limit

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0307) Set the ASR integral time at low speed. (0.000s~6.000s) F03.08 V/F SVC FVC PMV/F PMSVC PMFVC 0.0ms Filter Time 2 (0x0308) Set the ASR filter time at low speed.
  • Page 57: F03.2X: Torque Optimization

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0: C00.06 display the torque limit value during motoring 1: C00.06 display the torque limit value during generating F03.2x: Torque Optimization Code Default Name Content Property (Address) (Range) PM LF V/F SVC FVC PMV/F PMSVC PMFVC F03.20...
  • Page 58: F03.3X: Flux Optimization

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F03.3x: Flux Optimization Code Default Name Content Property (Address) (Range) Field-weakeni V/F SVC FVC PMV/F PMSVC PMFVC F03.30 10.0% Set the feed-forward coefficient under field (0x031E) Feed-forward (0.0%~500.0%) weakening control.
  • Page 59: F03.5X-03.8X: Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F03.46 V/F SVC FVC PMV/F PMSVC PMFVC Carrier (0x032E) Set the HF injection carrier. (0~10) F03.5x-03.8x: Extension Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC F03.50...
  • Page 60: F04: V/F Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0347) Open Loop Set the estimated open loop gain 2. (0.000~8.000) Gain 2 30.0% V/F SVC FVC PMV/F PMSVC PMFVC F03.72 Generating (0.0%~ (0x0348) Gain Set the generating gain.
  • Page 61: F04.1X: User-Defined V/F Curve

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0404) Compensatio Set the slip compensation range. (0.0%~300.0%) n Range V/F SVC FVC PMV/F PMSVC PMFVC Slip 0.200s F04.05 Enter the parameters on the motor's nameplate Compensatio (0.000s~ (0x0405)
  • Page 62 4 Parameter and Function Code Description AC600 Series AC Drive Manual (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC 0: Voltage percentage 1: Reserved 2: AI1 3: AI2 0x0000 F04.20 Voltage 4: Reserved (0x0000~ (0x0414) Source A 5: PUL terminal...
  • Page 63: F04.3X: V/F Eco Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F04.3x: V/F ECO Control Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC F04.30 V/F ECO 0: OFF STOP (0x041E) Mode (0~1) 1: ON 15.0Hz F04.31...
  • Page 64: F04.6X: V/F Pm Current Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F04.53 Controller V/F SVC FVC PMV/F PMSVC PMFVC 5.0% (0x0435) Frequency Set the flux controller frequency. (0%~100.0%) F04.54 Controller V/F SVC FVC PMV/F PMSVC PMFVC 7.0s (0x0436) Time Set the flux controller time.
  • Page 65: F05: Di Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Light-load F04.76 V/F SVC FVC PMV/F PMSVC PMFVC 20.0% Current Iq (0x044C) Set the light-load current Iq threshold. (0%~50.0%) Threshold Current F04.77 V/F SVC FVC PMV/F PMSVC PMFVC 50.0%...
  • Page 66: F05.1X-F05.2X: Terminal Operation Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F05.1x-F05.2x: Terminal Operation Control Code Default Name Content Property (Address) (Range) 0.010s F05.10 X1 ON V/F SVC FVC PMV/F PMSVC PMFVC (0.000s~ (0x050A) Delay Set the delay time for terminal X1 from OFF to ON.
  • Page 67: F05.3X: Pul Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F05.3x: PUL Terminal Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC F05.30 Signal Source 0: X6 STOP (0x051E) (0~1) 1: X10 extension V/F SVC FVC PMV/F PMSVC PMFVC Set the min.
  • Page 68: F06: Do Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Tens-bit: vX2 Hundreds-bit: vX3 Thousands-bit: vX4 V/F SVC FVC PMV/F PMSVC PMFVC 0: Internal connection with vYn terminal 1: Connection with Xn terminal 0x0000 F05.49 vX5~vX8 2: Funcode (0x0000~...
  • Page 69: F06.3X~F06.5X: Vy Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 60.000s) 0.010s V/F SVC FVC PMV/F PMSVC PMFVC F06.14 RO2 ON (0.000s~ (0x060E) Delay Set the delay time for RO2 from OFF to ON. 60.000s) 0.010s V/F SVC FVC PMV/F PMSVC PMFVC F06.15...
  • Page 70: F07X: Ai Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0.010s F06.48 vY6 ON V/F SVC FVC PMV/F PMSVC PMFVC (0.000s~ (0x0630) Delay Set the delay time for terminal vY6 from OFF to ON. 60.000s) 0.010s F06.49 vY6 OFF V/F SVC FVC PMV/F PMSVC PMFVC (0.000s~...
  • Page 71: F07.2X: Curve 1 Setting

    4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC 0.100s F07.14 Line 1 Filter Define the size of the filter applied to the analog (0.000s~ STOP (0x070E) Time signal to remove interfering signals.
  • Page 72: F07.4X: Ai As Xi

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Inflection 30.00% F07.32 V/F SVC FVC PMV/F PMSVC PMFVC Point 1 Input (0.00%~ (0x0720) Set the curve 2 inflection point 1 input voltage. Voltage 100.00%) Inflection V/F SVC FVC PMV/F PMSVC PMFVC 30.00%...
  • Page 73: F08.1X: Ao2

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4: Fixed frequency V/F SVC FVC PMV/F PMSVC PMFVC 0: Given frequency 1: Output frequency 2: Output current 3: Input voltage 4: Output voltage 5: Mechanical speed 6: Given torque...
  • Page 74: F09: Operation Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 10: Output power 11: Bus voltage 12: AI1 value 13: AI2 value 14: Reserved 15: PUL 16: Module temp. 1 17: Module temp. 2 18: 485 communication 19: vY1, 0 means OFF while 1 means ON Others: Connector (detailed in Chapter 7) 100.0%...
  • Page 75: F09.1X: Stop Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual default when the free stop, emergency stop or forced stop command are valid V/F SVC FVC PMV/F PMSVC PMFVC Ones-bit: Reverse operation direction 0: OFF 1: ON Tens-bit: Direction disable...
  • Page 76: F09.2X: Dc Braking

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F09.2x: DC Braking Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC 60.0% F09.20 Start DB 100.0% of the rated motor current, the upper limit of (0.0%~...
  • Page 77: F09.5X: Fly Track

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0.00Hz F09.44 Jump V/F SVC FVC PMV/F PMSVC PMFVC (0.00Hz~Max (0x072C) Frequency 1 Set the jump frequency 1. . frequency) Jump 0.00Hz F09.45 V/F SVC FVC PMV/F PMSVC PMFVC Frequency (0.00Hz~Max...
  • Page 78: F10: Protection Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.13 F10: Protection Parameters F10.0x: Current Protection Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Set the auto limit below the set overcurrent suppression point to prevent faults triggered by F10.00...
  • Page 79: F10.1X: Voltage Protection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F10.1x: Voltage Protection Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC If the bus voltage is higher than the anti-overvoltage limit, acceleration and deceleration will be slowed down or canceled to prevent overvoltage faults.
  • Page 80: F10.3X: Load Protection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Input Phase V/F SVC FVC PMV/F PMSVC PMFVC F10.21 10.0% Loss Set the voltage detection percentage for the input STOP (0x0A15) (0.0%~30.0%) Threshold phase loss detection, 100% of the rated bus voltage.
  • Page 81: F10.4X: Stall Protection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual is higher than the load alarm threshold for the set time here, report load alarm 1. V/F SVC FVC PMV/F PMSVC PMFVC Set the value for load alarm 2.
  • Page 82: F10.6X-F10.8X: Error Handling

    4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC 0: Common motor F10.50 Motor Type 1: Variable frequency motor (50Hz) (0x0A32) (0~3) 2: Variable frequency motor (60Hz) 3: Motor without fans V/F SVC FVC PMV/F PMSVC PMFVC...
  • Page 83 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0A46) Reset Auto 54-69 errors reset (0x0000~ Attribution 5 1: ON 0xFFFF) 2: OFF V/F SVC FVC PMV/F PMSVC PMFVC Auto Error 0x0000 F10.71 Auto 70-85 errors reset Reset...
  • Page 84 4 Parameter and Function Code Description AC600 Series AC Drive Manual Tens-bit: W-phase output loss 0x4444) Hundreds-bit: Motor overheat Thousands-bit: External error 0: Free stop 1: F09.10 2: Operation at limited frequency 3: Operation at limited current 4: Operation at limited power...
  • Page 85: F11: Keypad Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0: Free stop 1: F09.10 2: Operation at limited frequency 3: Operation at limited current 4: Operation at limited power 5: Report alarm 6: Ignore V/F SVC FVC PMV/F PMSVC PMFVC F10.90...
  • Page 86: F11.1X: Cyclic Monitoring Of Status Interface

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Hundreds-bit: Conditions 0: Modifiable during operation and stop 1: Modifiable during operation, kept during stop 2: Modifiable during operation, cleared after stop Thousands-bit: Reserved V/F SVC FVC PMV/F PMSVC PMFVC Ones- and tens-bit: Set 00~99 to yy in Fxx.yy...
  • Page 87 4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC Parameter 1 Ones- and tens-bit: Set 00~63 to yy in the Cxx.yy of 0x0000 F11.11 for 1st Row the monitor parameter code (0x0000~...
  • Page 88: F11.2X: Monitoring Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F11.2x: Monitoring Parameters Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Ones-bit: Output frequency display 0: Target frequency 1: Operation frequency 0x0002 F11.20 Keypad...
  • Page 89: F12: Communication Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.15 F12: Communication Parameters F12.0x: Modbus Slave Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC F12.00 RS485 (0x0C00) 0: Slave STOP Master/Slave (0~1) STOP...
  • Page 90: F12.1X: Modbus Master

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F12.1x: Modbus Master Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Ones-, tens-, hundreds-, and thousands-bit: 0: OFF 1: Running command 2: Given frequency...
  • Page 91: F13: Pid Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0xFFFF) 0x0000 V/F SVC FVC PMV/F PMSVC PMFVC F12.35 IP Address 6 (0x0000~ (0x0C23) Users fill in the parameter address as needed. 0xFFFF) 0x0000 V/F SVC FVC PMV/F PMSVC PMFVC F12.36...
  • Page 92: F13.07~F13.24: Pid Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 8: Reserved 9: Reserved 10: Reserved 11: Reserved 12: Reserved 13: Reserved 14: Terminal 15: Active current given via communication 16: AI1+AI2 17: AI1-AI2 18: MAX. [AI1, AI2] 19: MIN. [AI1, AI2] Others: Connector (detailed in Chapter 7) 0.010s...
  • Page 93 4 Parameter and Function Code Description AC600 Series AC Drive Manual gain increases strength but may cause oscillation. V/F SVC FVC PMV/F PMSVC PMFVC F13.15 Integral Sets the strength of the integral action; shorter times 1.0s (0x0D0F) Time I2 increase strength. An integral time of 0 disables PID (0.0s~600.0s)
  • Page 94: F13.25~F13.28: Pid Feedback Break

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F13.25~F13.28: PID Feedback Break Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC 0: Continue PID operation without reporting error F13.25 Feedback 1: Stop and report error...
  • Page 95: F14: Simulated Plc For Multi-Frequency

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: Frequency wake 2: Deviation or frequency wake V/F SVC FVC PMV/F PMSVC PMFVC 20.00Hz F13.36 Wakeup When the frequency wake is valid, if the PID output (0.00Hz~Max. (0x0D24)
  • Page 96: F14.15: Plc Operation Mode

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0E09) Multi-freque This parameters is used to set the operating (0.00Hz~Max. ncy 10 frequency of the 10th segment speed in PLC program frequency) and multi-frequency control. V/F SVC FVC PMV/F PMSVC PMFVC 30.00Hz...
  • Page 97: F14.31~14.45: Plc Direction And Acc/Dec Time

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x0E13) Runtime Set the stage 4 runtime by PLC. (0.0 (s/m/h) ~ 6500.0 (s/m/h)) 10.0 (s/m/h) V/F SVC FVC PMV/F PMSVC PMFVC F14.20 Stage (0.0 (s/m/h) ~ (0x0E14) Runtime Set the stage 5 runtime by PLC.
  • Page 98 4 Parameter and Function Code Description AC600 Series AC Drive Manual ACC/DEC 0x0031) Time Direction 0x0000 F14.34 The same as F14.31. (0x0000~ (0x0E22) ACC/DEC 0x0031) Time Direction 0x0000 F14.35 The same as F14.31. (0x0000~ (0x0E23) ACC/DEC 0x0031) Time Direction 0x0000 F14.36...
  • Page 99: F15: Torque Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.18 F15: Torque Control F15.0x: Torque Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC 0: Torque limit under speed control F15.00 1: Speed limit under motor 1 torque control...
  • Page 100: F16: Auxiliary Function 1

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (Address) (Range) 150.0% F15.10 V/F SVC FVC PMV/F PMSVC PMFVC Max. Torque (0.0%~ (0x0F0A) Set the max. given torque. 250.0%) 0.0% F15.11 V/F SVC FVC PMV/F PMSVC PMFVC Min. Torque (0.0%~...
  • Page 101: F16.1X: Wobble Frequency

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x1003) Setting Set the value for the counting circuit. (0~65000) F16.04 Pulse No. Per V/F SVC FVC PMV/F PMSVC PMFVC 10.0 (0x1004) Meter Set the counting value per meter.
  • Page 102: F16.4X: Frequency Detection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual F16.4x: Frequency Detection Code Default Name Content Property (Address) (Range) 2.00Hz V/F SVC FVC PMV/F PMSVC PMFVC F16.40 Frequency (0.00Hz~Max. (0x1028) Level 1 Set the frequency detection level 1.
  • Page 103: F25: Factory Calibration

    4 Parameter and Function Code Description AC600 Series AC Drive Manual parameter Cxx.yy 0x1599) Hundreds- and thousands-bit: Set 00~07 to xx in the monitor parameter Cxx.yy F16.66 Comparator 4 V/F SVC FVC PMV/F PMSVC PMFVC (0x1042) Upper Limit Set the upper limit of Comparator 4.
  • Page 104: F25.24~F25.35: Ao1 Correction

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC 0.500V F25.12 Measured correction voltage, enter the measured value into (0.000V~ (0x190C) Voltage 1 this parameter.
  • Page 105: F25.36~F25.47: Ao2 Correction

    4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC 9.500V F25.29 Measured Monitoring value of 3 correction voltage, enter the (0.000V~ (0x191D) Voltage 3 C05.62 value into this parameter. 11.000V) V/F SVC FVC PMV/F PMSVC PMFVC 1.000mA...
  • Page 106: A00: Default Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual parameter. 21.000mA) V/F SVC FVC PMV/F PMSVC PMFVC 19.000mA F25.35 Measured Monitoring value of 3 correction current, enter the (0.000mA~ (0x1923) Current 3 C05.63 value into this parameter. 21.000mA) 4.21 A00: Default Parameters...
  • Page 107 4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC 0x0000 A00.19 Funcode 10 Set the xx.yy of the function code; e.g., for F01.09, set (0x0000~ STOP (0x4013) it to 0109. 0x2999) A00.20...
  • Page 108: D00: Motor Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.22 d00: Motor Parameters d00.0x: Motor Control Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Current 1: Motor Parameter 1 0.500V d00.00 Motor 2: Motor Parameter 2 (0.000V~...
  • Page 109 4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC d01.00 Set the motor type. Type READ (0x6100) 0: Asynchronous motor (AM) (0~1) 1: Permanent magnet synchronous motor (PM) V/F SVC FVC PMV/F PMSVC PMFVC d01.01...
  • Page 110: D01.1X: Am Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d01.1x: AM Parameters Code Default Name Content Property (Address) (Range) d01.10 No-load V/F SVC FVC PMV/F PMSVC PMFVC Up to model STOP (0x610A) Current Set the no-load current for asynchronous motors.
  • Page 111: D01.4X~D01.5X: Pm D/Q-Axis Inductance Saturation Coefficient

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Inductance synchronous motors. 655.35%) Per-unit V/F SVC FVC PMV/F PMSVC PMFVC Up to model d01.27 Q-Axis Set the per-unit d-axis inductance for permanent magnet (0.01%~ READ (0x611B) Inductance synchronous motors.
  • Page 112: D01.6X~D01.7X: Tuning Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Saturation permanent magnet synchronous motors. Coefficient 0 Q-Axis V/F SVC FVC PMV/F PMSVC PMFVC d01.51 Inductance Set the Q-axis inductance saturation coefficient 1 for 100.0% (0x6133) Saturation permanent magnet synchronous motors.
  • Page 113: D02: Motor 2 Vector Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Increment 20.00%) Resistor V/F SVC FVC PMV/F PMSVC PMFVC d01.65 Tuning Bus (0x6141) Set the mean bus voltage for resistor online tuning. (0~65535) Voltage Resistor V/F SVC FVC PMV/F PMSVC PMFVC d01.66...
  • Page 114: D02.1X: Acr And Torque Limit

    4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC d02.00 Rigidity Set the rigidity level, the higher the level, the better (0x6200) Level (0~128) the speed rigidity. d02.02 Proportional V/F SVC FVC PMV/F PMSVC PMFVC 10.00...
  • Page 115: D02.2X: Torque Optimization

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 6: RS485 communication (0x3014) 7: Reserved (0x31 group) V/F SVC FVC PMV/F PMSVC PMFVC Set the frequency range limited by torque when at low speed. 0: Keypad Regenerating 1: Reserved d02.18...
  • Page 116: D02.4X: Pm Hf Injection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Field-weak V/F SVC FVC PMV/F PMSVC PMFVC ening d02.30 10.0% Feed-forwa Set the feed-forward coefficient under field weakening (0x621E) (0.0%~500.0%) control. Coefficient Field-weak V/F SVC FVC PMV/F PMSVC PMFVC d02.31...
  • Page 117: D02.5X~D02.6X: Vc Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x622D) Injection Debug the high-frequency injection. (0~65535) Debugging V/F SVC FVC PMV/F PMSVC PMFVC d02.46 Injection (0x622E) Set the high-frequency injection carrier. (0~10) Carrier d02.5x~d02.6x: VC Extension Code Default...
  • Page 118: D03: Motor 2 V/F Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x6250) Direct Flux Set the estimated gain under direct flux vector mode. (0.~65535) Vector Gain d02.81 V/F SVC FVC PMV/F PMSVC PMFVC 1.000 AFO Gain 1 (0x6251) Adjust the AFO1 control gain.
  • Page 119: D03.2X: Vf-Split Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d03.10 V/F SVC FVC PMV/F PMSVC PMFVC 3.0% (User-define STOP (0x630A) Set the V1 (user-defined voltage). (0.0%~100.0%) d Voltage) 1.00Hz d03.11 V/F SVC FVC PMV/F PMSVC PMFVC (User-define (0.00Hz~Max.
  • Page 120: D03.3X: V/F Eco Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Combinatio 1: Source B 0xFFFF) 2: Source A+Source B 3: Source A-Source B 4: Max. (A or B) 5: Min. (A or B) V/F SVC FVC PMV/F PMSVC PMFVC 0.00%...
  • Page 121: D03.5X: V/F Pm Flux Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Active 5.000Hz V/F SVC FVC PMV/F PMSVC PMFVC d03.43 Current (0Hz~ (0x632B) Filter Set the active current filter bandwidth. 65535Hz) Bandwidth Damper d03.44 V/F SVC FVC PMV/F PMSVC PMFVC 20.0%...
  • Page 122: D04: Motor 3 Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual D-Axis d03.69 V/F SVC FVC PMV/F PMSVC PMFVC 1000 Weakening (0x6345) Set the D-axis integral weakening coefficient. (0~1024) Integral D-Axis V/F SVC FVC PMV/F PMSVC PMFVC Proportional 80.0% d03.70...
  • Page 123: D04.1X: Am Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC d04.00 Set the motor type. Type READ (0x6400) 0: Asynchronous motor (AM) (0~1) 1: Permanent magnet synchronous motor (PM) d04.01 V/F SVC FVC PMV/F PMSVC PMFVC Pole No.
  • Page 124: D04.2X: Pm Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Up to model d04.12 Rotor V/F SVC FVC PMV/F PMSVC PMFVC (1mΩ~ STOP (0x640C) Resistance Set the rotor resistance for asynchronous motors. 65535mΩ) Stator V/F SVC FVC PMV/F PMSVC PMFVC Up to model d04.13...
  • Page 125: D04.4X~D04.5X: Pm D/Q-Axis Inductance Saturation Coefficient

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 0x3322) d04.30 Frequency V/F SVC FVC PMV/F PMSVC PMFVC STOP (0x641E) Decimal Bit Display the decimal bit of motor frequency. (0~3) d04.4x~d04.5x: PM D/Q-Axis Inductance Saturation Coefficient Code Default...
  • Page 126: D04.6X~D04.7X: Tuning Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Saturation permanent magnet synchronous motors. 2000.0%) Coefficient Q-Axis Inductance V/F SVC FVC PMV/F PMSVC PMFVC 100.0% d04.51 Saturation Set the Q-axis inductance saturation coefficient 1 for (0.1%~ (0x6433) Coefficient permanent magnet synchronous motors.
  • Page 127 4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC Resistor 0: OFF d04.62 Online 1: Auto-tuning after power-up (0x643E) (0~3) Tuning 2: Auto-tuning after start 3: Auto-tuning during operation V/F SVC FVC PMV/F PMSVC PMFVC d04.63...
  • Page 128: D05: Motor 3 Vector Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d04.78 Filter V/F SVC FVC PMV/F PMSVC PMFVC STOP (0x644E) Resistance Set the LC filter resistance. (0.0~6500.0) 4.27 d05: Motor 3 Vector Control d05.0x: ASR Control Code Default Name...
  • Page 129: D05.1X: Acr And Torque Limit

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d05.1x: ACR and Torque Limit Code Default Name Content Property (Address) (Range) D-Axis V/F SVC FVC PMV/F PMSVC PMFVC d05.10 1.000 Proportional (0x650A) Set the current loop D-axis proportional gain.
  • Page 130: D05.2X: Torque Optimization

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d05.2x: Torque Optimization Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC d05.20 PM LF Drag 20.0% When the SVC mode of the PM is on, the larger the...
  • Page 131: D05.4X: Pm Hf Injection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: ON d05.38 Min ECO V/F SVC FVC PMV/F PMSVC PMFVC 50.0% (0x6526) Excitation Set the lower limit of energy-saving excitation. (0.0%~80.0%) 0.010s d05.39 ECO Filter V/F SVC FVC PMV/F PMSVC PMFVC (0.000s~6.000s...
  • Page 132 4 Parameter and Function Code Description AC600 Series AC Drive Manual Limit Regenerativ V/F SVC FVC PMV/F PMSVC PMFVC d05.66 6.00% e Torque Set the frequency range limited by torque when at low (0x6542) (0.00%~30.00%) Limit speed. Frequency Estimated V/F SVC FVC PMV/F PMSVC PMFVC d05.70...
  • Page 133: D06: Motor 3 V/F Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.28 d06: Motor 3 V/F Control d06.0x: V/F Control Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC Select the type of V/F curve according to different load characteristics.
  • Page 134: D06.2X: Vf-Split Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x660D) (User-define Set the F2 (user-defined frequency). (0.00Hz~Max. d Frequency) frequency) V/F SVC FVC PMV/F PMSVC PMFVC d06.14 55.0% (User-define STOP (0x660E) Set the V3 (user-defined voltage). (0.0%~100.0%) d Voltage) 25.00Hz...
  • Page 135: D06.3X: V/F Eco Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC d06.24 Voltage 10.00s Set the voltage acceleration time under V/F-SPLIT (0x6618) ACC Time (0.00s~100.00s) control. V/F SVC FVC PMV/F PMSVC PMFVC d06.25 Voltage 10.00s...
  • Page 136: D06.5X: V/F Pm Flux Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Anti-oscilla d06.46 V/F SVC FVC PMV/F PMSVC PMFVC tion Start (0x662E) Set the anti-oscillation start frequency. (0%~F4.79%) Frequency d06.5x: V/F PM Flux Control Code Default Name Content Property (Address) (Range) d06.50...
  • Page 137 4 Parameter and Function Code Description AC600 Series AC Drive Manual Frequency D-Axis Proportiona V/F SVC FVC PMV/F PMSVC PMFVC d06.71 120.0% l Gain Shift Set the OFF frequency for D-axis proportional gain (0x6647) (0%~6553.5%) shifting. Frequency HF D-Axis V/F SVC FVC PMV/F PMSVC PMFVC d06.72...
  • Page 138: D07: Motor 4 Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.29 d07: Motor 4 Parameters d07.0x: Basic Parameters and Auto-tuning Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC d07.00 Set the motor type. Type...
  • Page 139: D07.2X: Pm Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x670E) Inductance Set the stator inductance for asynchronous motors. (1mH~65535mH) Per-unit V/F SVC FVC PMV/F PMSVC PMFVC d07.15 Up to model Stator READ (0x670F) Set the per-unit stator resistance.
  • Page 140: D07.4X~D07.5X: Pm D/Q-Axis Inductance Saturation Coefficient

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d07.4x~d07.5x: PM D/Q-Axis Inductance Saturation Coefficient Code Default Name Content Property (Address) (Range) D-Axis Inductance V/F SVC FVC PMV/F PMSVC PMFVC d07.40 100.0% Saturation Set the D-axis inductance saturation coefficient 0 for (0x6728) (0.1%~2000.0%)
  • Page 141: D07.6X~D07.7X: Tuning Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x6733) Inductance Set the Q-axis inductance saturation coefficient 1 for (0.1%~2000.0%) Saturation permanent magnet synchronous motors. Coefficient Q-Axis V/F SVC FVC PMV/F PMSVC PMFVC Inductance Set the Q-axis inductance saturation coefficient 2 for d07.52...
  • Page 142 4 Parameter and Function Code Description AC600 Series AC Drive Manual 3: Auto-tuning during operation d07.63 Resistor V/F SVC FVC PMV/F PMSVC PMFVC (0x673F) Tuning Rate Set the resistor tuning rate. (0~1000) d07.64 Resistor V/F SVC FVC PMV/F PMSVC PMFVC 0.00%...
  • Page 143: D08: Motor 4 Vector Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.30 d08: Motor 4 Vector Control d08.0x: ASR Control Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC d08.00 Rigidity Set the rigidity level, the higher the level, the better...
  • Page 144: D08.2X: Torque Optimization

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Generating d08.16 V/F SVC FVC PMV/F PMSVC PMFVC 250.0% Torque (0x6810) Set the torque limit in power generation mode. (0.0%~400.0%) Limit V/F SVC FVC PMV/F PMSVC PMFVC Set the regenerative torque limit at low speed.
  • Page 145: D08.3X: Flux Optimization

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d08.29 V/F SVC FVC PMV/F PMSVC PMFVC 0.0% Flux Range (0x681D) Set the flux range. (0.0%~150.0%) d08.3x: Flux Optimization Code Default Name Content Property (Address) (Range) Field-weak V/F SVC FVC PMV/F PMSVC PMFVC ening d08.30...
  • Page 146: D08.4X: Pm Hf Injection

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d08.4x: PM HF Injection Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC When the SVC mode of the PM is on, please select 0 d08.40...
  • Page 147: D09: Motor 4 V/F Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Limit Frequency Estimated V/F SVC FVC PMV/F PMSVC PMFVC d08.70 1.000 SVC Gain (0x6846) Set the estimated open loop gain 1. (0.000~8.000) Estimated V/F SVC FVC PMV/F PMSVC PMFVC d08.71...
  • Page 148: D09.1X: User-Defined V/F Curve

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Frequency will be cut off when the output frequency exceeds this value. Slip V/F SVC FVC PMV/F PMSVC PMFVC d09.03 0.0% Compensati (0x6903) Set the slip compensation gain. (0.0%~200.0%)
  • Page 149: D09.2X: Vf-Split Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Frequency) V/F SVC FVC PMV/F PMSVC PMFVC d09.18 100.0% (User-defin STOP (0x6912) Set the V5 (user-defined voltage). (0.0%~100.0%) ed Voltage) 50.00Hz d09.19 (User-defin V/F SVC FVC PMV/F PMSVC PMFVC (0.00Hz~Max.
  • Page 150: D09.3X: V/F Eco Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d09.27 Voltage V/F SVC FVC PMV/F PMSVC PMFVC 0.00V (0x691B) Value Set the voltage value under V/F-SPLIT control. (0.00V~600.00V) d09.3x: V/F ECO Control Code Default Name Content Property (Address)
  • Page 151: D09.6X: V/F Pm Current Control

    4 Parameter and Function Code Description AC600 Series AC Drive Manual d09.52 Integral V/F SVC FVC PMV/F PMSVC PMFVC 1000 (0x6934) Gain Set the flux control integral gain. (0~9999) d09.53 Controller V/F SVC FVC PMV/F PMSVC PMFVC 5.0% (0x6935) Frequency Set the flux controller frequency.
  • Page 152: E00: Io Extension Input

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Filter filter. Bandwidth Q-Axis V/F SVC FVC PMV/F PMSVC PMFVC d09.74 Current 11.000Hz Set the bandwidth of the Q-axis current low-pass (0x694A) Filter (0Hz~65.535Hz) filter. Bandwidth D-Axis V/F SVC FVC PMV/F PMSVC PMFVC d09.75...
  • Page 153: E00.1X~3X: Extension Di Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual E00.1x~3x: Extension DI Terminal Code Default Name Content Property (Address) (Range) E00.10 V/F SVC FVC PMV/F PMSVC PMFVC X7 Function STOP (0x700A) See the function of terminal X. (0~95) E00.11...
  • Page 154: E00.4X~5X: Extension Ai Terminal

    4 Parameter and Function Code Description AC600 Series AC Drive Manual E00.4x~5x: Extension AI Terminal Code Default Name Content Property (Address) (Range) V/F SVC FVC PMV/F PMSVC PMFVC E00.40 AI3 Type 0: Voltage 0.00V~10.00V (0x7028) (0~1) 1: Current 0.00mA~20.00mA V/F SVC FVC PMV/F PMSVC PMFVC...
  • Page 155 4 Parameter and Function Code Description AC600 Series AC Drive Manual V/F SVC FVC PMV/F PMSVC PMFVC 0: OFF 1: Report alarm and free stop 0x0000 E00.56 Temp. Alarm 2: Report alarm and continue operation (0x0000~ (0x7038) Mode 0x2222) Ones-bit: Temp.1 mode Tens-bit: Temp.2 mode...
  • Page 156: E01: Io Extension Output

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 4.33 E01: IO Extension Output E01.0x~1x: Extension DO Terminal Code Default Name Content Property (Address) (Range) E01.00 V/F SVC FVC PMV/F PMSVC PMFVC Y2 Terminal (0x7100) See the functions of terminal Y.
  • Page 157: E02: Encoder 1 Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual E01.32 V/F SVC FVC PMV/F PMSVC PMFVC 100.0% AO3 Gain (0x7120) Set the gain value of the analog output. (0.0%~300.0%) V/F SVC FVC PMV/F PMSVC PMFVC 0.0% E01.33 AO3 Bias Set the AO3 bias.
  • Page 158: E02.2X: Resolver Encoder 1

    4 Parameter and Function Code Description AC600 Series AC Drive Manual E02.12 V/F SVC FVC PMV/F PMSVC PMFVC 1024 Line No. (0x720C) Set the number of lines for ABZ encoder. (0~16384) E02.13 Ratio V/F SVC FVC PMV/F PMSVC PMFVC (0x720D) Numerator Set the encoder ratio numerator.
  • Page 159: E03.1X: Abz Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: ON Tens-bit: PG configuration 0: Filter ON 1: Filter OFF 3: Z-pulse accumulated error 4: Pulse clear E03.03 Encoder V/F SVC FVC PMV/F PMSVC PMFVC (0x7303) Break Check Detect for encoder break.
  • Page 160: E04: Extension 1 Common Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: Endat 2: SSI E03.31 V/F SVC FVC PMV/F PMSVC PMFVC 20.48 Line No. STOP (0x731F) Set the line number of the sine/cosine encoder. (0.50~168.34) 4.36 E04: Extension 1 Common Parameters...
  • Page 161 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x741A) Output Set the address 7 for Ex1 process data output. (0~65535) Address 7 Ex1 Data V/F SVC FVC PMV/F PMSVC PMFVC E04.27 Output STOP (0x741B) Set the address 8 for Ex1 process data output.
  • Page 162 4 Parameter and Function Code Description AC600 Series AC Drive Manual Base Address Ex1 Data V/F SVC FVC PMV/F PMSVC PMFVC E04.46 Output 11 STOP (0x742E) Set the base address for Ex1 process data output 11. (0~65535) Base Address Ex1 Data V/F SVC FVC PMV/F PMSVC PMFVC E04.47...
  • Page 163: E05: Extension 2 Common Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Ex1 Data E04.65 V/F SVC FVC PMV/F PMSVC PMFVC Input 14 STOP (0x7441) Set the base address for Ex1 process data input 14. (0~65535) Base Address Ex1 Data E04.66...
  • Page 164 4 Parameter and Function Code Description AC600 Series AC Drive Manual Ex2 Data E05.24 V/F SVC FVC PMV/F PMSVC PMFVC Output (0x7518) Set the address 5 for Ex2 process data output. (0~65535) Address 5 Ex2 Data E05.25 V/F SVC FVC PMV/F PMSVC PMFVC...
  • Page 165 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x752B) Output 8 Set the base address for Ex2 process data output 8. (0~65535) Base Address Ex2 Data V/F SVC FVC PMV/F PMSVC PMFVC E05.44 Output 9 STOP (0x752C) Set the base address for Ex2 process data output 9.
  • Page 166: E06: Can/Dp Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Address Ex2 Data V/F SVC FVC PMV/F PMSVC PMFVC E05.63 Input 12 STOP (0x753F) Set the base address for Ex2 process data input 12. (0~65535) Base Address Ex2 Data V/F SVC FVC PMV/F PMSVC PMFVC E05.64...
  • Page 167: E07: Ethecat Extension

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x7626) CAN_ID Set via MAC address e-f. (384~1407) E06.39 RPDO3 V/F SVC FVC PMV/F PMSVC PMFVC STOP (0x7627) Mode Define the client 2 access timeout. (0~255) V/F SVC FVC PMV/F PMSVC PMFVC E06.40...
  • Page 168 4 Parameter and Function Code Description AC600 Series AC Drive Manual (Address) (Range) E07.00 Module V/F SVC FVC PMV/F PMSVC PMFVC (0x7700) Online Status Set the module online status. (0~65535) E07.01 Slave Station V/F SVC FVC PMV/F PMSVC PMFVC (0x7701) Name Set the EtherCAT slave station name.
  • Page 169: E08: Plc Extension Parameter

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Timeout E07.60 DHCP Enable the DHCP. (0x773C) (0~65535) V/F SVC FVC PMV/F PMSVC PMFVC E07.61 IP Address a (0x773D) Set the IP address a. (0~65535) V/F SVC FVC PMV/F PMSVC PMFVC E07.62...
  • Page 170 4 Parameter and Function Code Description AC600 Series AC Drive Manual Detection 1: ON Receive 10.00s V/F SVC FVC PMV/F PMSVC PMFVC E10.04 Timeout (0.00s~ (0x7A04) Set the receive timeout judgment time. Judgment 100.00s) ADC Data 0x0000 V/F SVC FVC PMV/F PMSVC PMFVC E10.06...
  • Page 171: L00: Free Function Block

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 2ms Data 0x0000 E10.24 V/F SVC FVC PMV/F PMSVC PMFVC Custom (0x0000~ (0x7A18) Set the 2ms data custom channel 14. Channel 14 0x4F99) 2ms Data 0x0000 E10.25 V/F SVC FVC PMV/F PMSVC PMFVC...
  • Page 172: L00.2X: Module 3

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x800A) Function Refer to the details in Free Module Function. (0~38) V/F SVC FVC PMV/F PMSVC PMFVC 0: Invalid L00.11 Input 1 1: Constant (0x800B) Type (0~3) 2: Address No.
  • Page 173: L00.4X: Module 5

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Input 2 V/F SVC FVC PMV/F PMSVC PMFVC L00.26 Bit(Bit Bitwise operations are valid for address parameter (0x801A) operation (0~99) inputs. valid) V/F SVC FVC PMV/F PMSVC PMFVC 0: Invalid L00.27...
  • Page 174 4 Parameter and Function Code Description AC600 Series AC Drive Manual L00.40 Module 5 V/F SVC FVC PMV/F PMSVC PMFVC (0x8028) Function Refer to the details in Free Module Function. (0~38) V/F SVC FVC PMV/F PMSVC PMFVC 0: Invalid L00.41...
  • Page 175: L00.6X: Module 7

    4 Parameter and Function Code Description AC600 Series AC Drive Manual L00.5x: Module 6 Code Default Name Content Property (Address) (Range) L00.50 Module 6 V/F SVC FVC PMV/F PMSVC PMFVC (0x8032) Function Refer to the details in Free Module Function.
  • Page 176 4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: Constant 2: Address No. 3: Bitwise operation of address parameters L00.65 Input 2 V/F SVC FVC PMV/F PMSVC PMFVC (0x8041) ID/Value Set the constant value for input. (0~65535)
  • Page 177: L00.9X: Module 10

    4 Parameter and Function Code Description AC600 Series AC Drive Manual valid) L00.8x: Module 9 Code Default Name Content Property (Address) (Range) L00.80 Module 9 V/F SVC FVC PMV/F PMSVC PMFVC (0x8050) Function Refer to the details in Free Module Function.
  • Page 178: U00: Bit Connector 1

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x805E) Type 0: Invalid (0~3) 1: Constant 2: Address No. 3: Bitwise operation of address parameters L00.95 Input 2 V/F SVC FVC PMV/F PMSVC PMFVC (0x805F) ID/Value Set the constant value for input.
  • Page 179 4 Parameter and Function Code Description AC600 Series AC Drive Manual U00.15 X5 Final Status X5 status after delay processing (0xA00F) U00.16 X5 Final Status Inversion Inverted X5 status after delay processing (0xA010) U00.17 X6 Physical Status X6 original status before processing (0xA011) U00.18...
  • Page 180 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0xA037) U00.56 Y1 Output Status Monitor the output state of Y1 (0xA038) U00.57 Y1 Output Status Inversion Monitor the inverted output state of Y1 (0xA039) U00.58 Y2 Output Status...
  • Page 181: U01.Xx: Bit Connector 2 (Function Status Indicator)

    4 Parameter and Function Code Description AC600 Series AC Drive Manual U00.88 XY2 Original Status Monitor the XY2 original status (0xA058) U00.89 XY2 Final/Output Status Monitor the XY2 final/output status (0xA059) U00.90 XY2 Final/Output Status Monitor the inverted XY2 final/output status...
  • Page 182 4 Parameter and Function Code Description AC600 Series AC Drive Manual U01.20 Meter Length Arrival (0xA114) U01.21 Timing Arrival (0xA115) U01.22 Counter Maximum Arrival (0xA116) U01.23 Counter Setting Arrival (0xA117) U01.24 Dynamic Braking (0xA118) U01.25 PG Feedback Break (0xA119) U01.26...
  • Page 183: U03.Xx: Word Connector 1 (Typical Frequency/Voltage)

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0xA132) U01.51 REV Disable (0xA133) U01.52 Start DC Brake (0xA134) U01.54 Under Torque Control (0xA136) U01.55 Under Position Control (0xA137) U01.56 Jogging First (0xA138) U01.57 Undervoltage Suppressing (0xA139) U01.58...
  • Page 184 4 Parameter and Function Code Description AC600 Series AC Drive Manual U03.19 Source A Output (0xA313) U03.20 Source B Output (0xA314) U03.21 Frequency Source (0xA315) U03.30 Voltage Reference (Motor 0.1V (0xA31E) Rated Line Voltage Vn) U03.31 Bus Voltage Feedback, 1ms 0.1V...
  • Page 185: U04.Xx: Word Connector 2 (Internal Parameter Word 1)

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0xA33E) U03.63 Fault Current 0.1A (0xA33F) U03.64 U-Phase Current Sampling (0xA340) U03.65 V-Phase Current Sampling (0xA341) U03.66 W-Phase Current Sampling (0xA342) U03.67 U-Phase Current RMS 0.1% (0xA343) U03.68 V-Phase Current RMS 0.1%...
  • Page 186: U05.Xx: Word Connector 3 (Internal Parameter Word 2)

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0xA408) U04.09 AI2 Value Indicates the AI2 value. (0xA409) U04.10 AO1 Value Indicates the AO1 value. (0xA40A) U04.11 AO2 Value Indicates the AO2 value. (0xA40B) U04.12 Fault 1 Indicates the current fault subcode.
  • Page 187 4 Parameter and Function Code Description AC600 Series AC Drive Manual U05.20 0x3014 Control Word Read the data of address 0x3014 (0xA514) U05.21 0x3015 Control Word Read the data of address 0x3015 (0xA515) U05.22 0x3016 Control Word Read the data of address 0x3016 (0xA516) U05.23...
  • Page 188: U07.Xx: Dual Word Connector

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0xA530) U05.49 0x3111 Control Word Read the data of address 0x3111 (0xA531) U05.50 0x3112 Control Word Read the data of address 0x3112 (0xA532) U05.51 0x3113 Control Word Read the data of address 0x3113 (0xA533) U05.52...
  • Page 189 4 Parameter and Function Code Description AC600 Series AC Drive Manual U07.02 Module 1: Monitoring Monitor the input 2 of free module 1 (0xA702) Input 2 U07.04 Module 1: Monitoring Monitor the input 3 of free module 1 (0xA704) Input 3 U07.06...
  • Page 190: C0X: Monitoring Parameters

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0xA73A) Input 3 U07.60 Module 1: Monitoring Monitor the output 1 of free module (0xA73C) Output U07.62 Module 2: Monitoring Monitor the output 2 of free module (0xA73E) Output U07.64...
  • Page 191 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x210C) C00.13 Module Temp. 2 0.1℃ Display the drive internal temperature 2. (0x210D) The status of the terminal X is indicated by 1 (ON) and 0 (OFF). C00.14 Terminal X Status...
  • Page 192: C01.Xx: Error Record 1

    4 Parameter and Function Code Description AC600 Series AC Drive Manual C00.45 Current Alarm 2 Display the diagnostic information of drive (0x212D) Info current alarm 2. C00.46 Current Alarm 3 Display the diagnostic information of drive (0x212E) Info current alarm 3.
  • Page 193 4 Parameter and Function Code Description AC600 Series AC Drive Manual Tens-bit: Operation status 0: Stop 1: Stable running 2: Accelerating 3: Decelerating Hundreds-bit: Overvoltage and overcurrent 0: Normal 1: Overvoltage 2: Overcurrent 3: Overvoltage and overcurrent Thousands-bit: Reserved The status of the terminal X is displayed by 1 (ON) and 0 (OFF).
  • Page 194 4 Parameter and Function Code Description AC600 Series AC Drive Manual Ones-bit: Operation direction 0: Forward 1: Reverse Tens-bit: Operation status 0: Stop 1: Stable running C01.25 Previous 1 Error Drive 2: Accelerating 0x0000 (0x2219) Status 3: Decelerating Hundreds-bit: Overvoltage and overcurrent...
  • Page 195 4 Parameter and Function Code Description AC600 Series AC Drive Manual 2: Overcurrent 3: Overvoltage and overcurrent Thousands-bit: Reserved Ones-bit: Operation direction 0: Forward 1: Reverse Tens-bit: Operation status 0: Stop 1: Stable running C01.41 Previous 2 Error Drive 2: Accelerating...
  • Page 196 4 Parameter and Function Code Description AC600 Series AC Drive Manual Hundreds-bit: Overvoltage and overcurrent 0: Normal 1: Overvoltage 2: Overcurrent 3: Overvoltage and overcurrent Thousands-bit: Reserved Ones-bit: Operation direction 0: Forward 1: Reverse Tens-bit: Operation status 0: Stop 1: Stable running C01.57...
  • Page 197 4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: Stable running 2: Accelerating 3: Decelerating Hundreds-bit: Overvoltage and overcurrent 0: Normal 1: Overvoltage 2: Overcurrent 3: Overvoltage and overcurrent Thousands-bit: Reserved Ones-bit: Operation direction 0: Forward 1: Reverse...
  • Page 198: C02.Xx: Error Record 2

    4 Parameter and Function Code Description AC600 Series AC Drive Manual 1: Reverse Tens-bit: Operation status 0: Stop 1: Stable running 2: Accelerating 3: Decelerating Hundreds-bit: Overvoltage and overcurrent 0: Normal 1: Overvoltage 2: Overcurrent 3: Overvoltage and overcurrent Thousands-bit: Reserved...
  • Page 199 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x2305) Voltage C02.06 Previous 6 Error Module Display the temperature 1 of the drive inner 0.1℃ (0x2306) Temp.1 module during error. C02.07 Previous 6 Error Module Display the temperature 2 of the drive inner 0.1℃...
  • Page 200 4 Parameter and Function Code Description AC600 Series AC Drive Manual C02.20 Previous 7 Error Output 0.1A Display the output current during error. (0x2314) Current C02.21 Previous 7 Error Bus 0.1V Display the bus voltage during error. (0x2315) Voltage C02.22...
  • Page 201 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x2322) Frequency 0.1Hz C02.35 Previous 8 Error Output 0.1V Display the output voltage during error. (0x2323) Voltage C02.36 Previous 8 Error Output 0.1A Display the output current during error.
  • Page 202 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x2331) digital form, and check the corresponding solutions in the error diagnosis section. C02.50 Previous 9 Error Output 0.01Hz/ Display the output frequency during error. (0x2332) Frequency 0.1Hz C02.51 Previous 9 Error Output 0.1V...
  • Page 203 4 Parameter and Function Code Description AC600 Series AC Drive Manual C02.64 Previous 10 Error Code Display the current error in code. (0x2340) Display the error code and error sub-code in C02.65 Previous 10 Errcode Info digital form, and check the corresponding (0x2341) solutions in the error diagnosis section.
  • Page 204 4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x234E) Power-ON (h) of the drive in hours. C02.79 Previous 10 Error Total Display the previous 10 error total power-on time (0x234F) Power-ON (min) of the drive in minutes.
  • Page 205: C03.Xx: Operation Monitoring

    4 Parameter and Function Code Description AC600 Series AC Drive Manual C02.93 Previous 11 Error State Display the previous 11 error state flow of the (0x235D) Flow drive. C02.94 Previous 11 Error Total Display the previous 11 error total power-on time...
  • Page 206: C04.Xx: System Monitoring

    4 Parameter and Function Code Description AC600 Series AC Drive Manual C03.28 AB-Pulse Count (0x241C) C03.29 Drive Command Display the status of drive command. (0x241D) C03.30 Terminal Command Display the status of terminal X command. (0x241E) C03.31 Source Command Obtain the command from command source.
  • Page 207 4 Parameter and Function Code Description AC600 Series AC Drive Manual C04.10 Software Upgrader ID (0x250A) C04.11 Drive Version Drive module version (0x250B) C04.12 Drive Sub-version Drive module sub-version (0x250C) C04.13 Funcode Version Funcode Version No. (0x250D) C04.14 Keypad Version External keypad version No.
  • Page 208: C11.Xx: Io Communication Monitoring

    4 Parameter and Function Code Description AC600 Series AC Drive Manual C11.xx: IO Communication Monitoring Code Min. Name Content (Address) Precision C11.00 X Terminal Status Monitor the status of terminal X (0x2C00) C11.01 Y Terminal Status Monitor the status of terminal Y (0x2C01) C11.02...
  • Page 209 4 Parameter and Function Code Description AC600 Series AC Drive Manual C12.04 Ex1 Process Input Data 3 Monitor the original Ex1 process input data 3 (0x2D04) (Original) C12.05 Ex1 Process Input Data 4 Monitor the original Ex1 process input data 4...
  • Page 210: Terminal I/O Function

    4 Parameter and Function Code Description AC600 Series AC Drive Manual (0x2D20) (Original) C12.33 Ex2 Process Input Data 16 Monitor the original Ex2 process input data 16 (0x2D21) (Original) C12.34 PN Extension MAC0 0x0000 Monitor the PN extension MAC0 (0x2D22) C12.35...
  • Page 211 4 Parameter and Function Code Description AC600 Series AC Drive Manual Wobble Frequency Reserved Reserved Reset Jog Frequency Limit as Combined Frequency Keypad Keys Torque Mode Frequency Source to Source A Display Self-test Frequency Combined Frequency Measurement, 63~87 Reserved Source to Source B...
  • Page 212: Free Module Function

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Load Alarm 2 (Report External Error Stop FWD Disable error and alarm) Drive Low Voltage Drive in Alarm REV Disable 0x3018 Control AC Drive Ready DC Braking Output Output...
  • Page 213: Error And Alarm Codes

    4 Parameter and Function Code Description AC600 Series AC Drive Manual Divide Pulse to Level Arithmetic Square Logic Delay Root Differential Pulse Generator Compare Ramp Limit Transfer Max. Reserved Absolute Min. Reserved Avg. Reserved Subtract Filter Reserved 4.47 Error and Alarm Codes Note: The numbers in brackets in the code column are error codes and alarm codes.
  • Page 214 4 Parameter and Function Code Description AC600 Series AC Drive Manual Overvoltage E. ou2 (10) Error E. CP1 (96) Comparator 1 error Error during deceleration Overvoltage E. ou3 (11) Error E. CP2 (97) Comparator 2 error Error during constant speed Undervoltage E.
  • Page 215 4 Parameter and Function Code Description AC600 Series AC Drive Manual E. EF (33) External error Error A. SPD (134) Overspeed Alarm Communicatio E. CE (34) Error A. GPS1 (135) GPS lock Alarm n error Large U-phase E. HAL1 (35) Error A.
  • Page 216 4 Parameter and Function Code Description AC600 Series AC Drive Manual Initial angle E. iAE1 (71) Error A. FrA (157) Material fracture Alarm tuning failure 1 Initial angle E. iAE2 (72) Error A. OH4 (158) Motor overheat Alarm tuning failure 2...
  • Page 217: Maintenance

    5 Maintenance AC600 Series AC Drive Manual 5 Maintenance 5.1 Inspection The drives consist of semiconductor devices, passive electronic devices, and motion devices, all of which have a service life, and even under normal operating conditions, some of the devices may change in characteristics or fail if their service life is exceeded.
  • Page 218 5 Maintenance AC600 Series AC Drive Manual Item Content Solution Confirm whether the relevant cabinet Check the environment to see if there is any dirt or doors can be closed tightly; dust. Clean dirt or dust and improve the operating environment.
  • Page 219: Maintenance

    2. Primary troubleshooting will be carried out by your company, but the service can be provided by VEICHI or service network for a fee at your request. If the cause of malfunction is found to be on VEICHI, the service will be free of charge according to mutual negotiation.
  • Page 220: Sto Function

    6 STO Function AC600 Series AC Drive Manual 6 STO Function 6.1 Standards Safety Standards  Table 6-1 Safety Standards Item Standards EN/ISO 13849-1: 2015 EN/IEC 61508: 2010, Parts 1-7 Function safety EN/IEC 62061: 2021 EN/IEC 61800-5-2: 2017 EN/IEC 61326-3-1: 2017 Safety Performance ...
  • Page 221: Electrical Specifications And Connection

    High level Normal operation of the drive STO1 Low level Trigger STO function High level Normal operation of the drive STO2 Low level Trigger STO function Wiring Description  Single drive  Figure 6-1 AC600 Series Drive STO Terminal Connection...
  • Page 222 AC600 Series AC Drive Manual Parallel drives  Figure 6-2 Parallel AC600 Series Drives STO Terminal Connection The AC600 series drives support up to 2 parallel extensions. Configure the STO terminals on all drives and see the wiring diagram provided above. EMC requirements ...
  • Page 223: Commissioning And O&M Requirements

    6 STO Function AC600 Series AC Drive Manual 6.3 Commissioning and O&M Requirements 6.3.1 Basic Requirements Technicians shall be trained on safety system design and commission requirements and principles.  Operating and maintenance staff shall be trained on safety system design and operation requirements and ...
  • Page 224: Safety Function Monitoring

    6 STO Function AC600 Series AC Drive Manual Ensure the keypad still displays "STO fault/trigger, safe torque off," STO status cannot be restored Start the drive and ensure that the motor remains stopped Reset the safety switch, setting STO1 and STO2 to high level, and manually clear the STO...
  • Page 225: Safety Function Troubleshooting

    Before resetting STO, ensure the AC drive is returned to normal operation. Only the safety switch-triggered STO can be reset; for other errors, contact VEICHI support directly. When the safety switch triggers STO, the AC drive stops. To resume normal operation, manually reset the STO via the keypad and follow these steps: Reset the safety switch to reconnect the STO dual channels to the 24V supply.
  • Page 226: Safety Measures

    6 STO Function AC600 Series AC Drive Manual 6.5.1 Safety Measures When using this function, please read and follow these key precautions: The STO function is not an alternative for the emergency stop. It cannot disconnect power or de-energize the ...
  • Page 227: Fbd Function

    7 FBD Function AC600 Series AC Drive Manual 7 FBD Function 7.1 Free Programming This section introduces the free module functionality in FBD visual programming for the lower machine, designed to support user secondary development tailored to specific practical scenarios. We offer 10 free modules, each equipped with 38 application functions, featuring 3 inputs, 1 output, and 1 module status.
  • Page 228: Connector

    7 FBD Function AC600 Series AC Drive Manual 7.2 Connector To facilitate secondary development based on the existing functionality of the drive, the system incorporates a set of free modules and connector parameters. Connectors orderly arrange system parameters through specific parameter function codes (U group) and provide corresponding addresses for external access, including the inputs and outputs of free modules.
  • Page 229: Appendix I: Modbus Communication Protocol

    Appendix I: Modbus Communication Protocol AC600 Series AC Drive Manual Appendix I: Modbus Communication Protocol Communication frame structure The communication data format is as follows: Composition of bytes:Start bit, 8 data bits, parity bit and stop bit. Start bit Bit1...
  • Page 230 Appendix I: Modbus Communication Protocol AC600 Series AC Drive Manual V/F-SPLIT 0.0% Frequency conversion-specific power 0x300A Voltage (0.0%~100.0%) supply application parameters. 0x300B Tension Tension-specific unit application parameters (0~Max. tension) 0x300C Roll Diameter (0.0~Max. roll Tension-specific unit application parameters diameter) 20.0...
  • Page 231 Appendix I: Modbus Communication Protocol AC600 Series AC Drive Manual Info (0~65535) current error 3. Current Alarm 1 READ Display the diagnostic information of drive 0x3024 Info (0~65535) current alarm 1. Current Alarm 2 READ Display the diagnostic information of drive...
  • Page 232: Appendix Ii: Terminal Wiring Methods

    Appendix II: Terminal Wiring Methods AC600 Series AC Drive Manual Appendix II: Terminal Wiring Methods 0: Two-wire Control 1 Operation and direction are set at the same time. Two-wire mode is most commonly used in this mode. The factory default is that the X1(FWD operation) and X2(REV operation) terminal control the motor to run forward and reverse.
  • Page 233 Appendix II: Terminal Wiring Methods AC600 Series AC Drive Manual 3: Three-wire Control 2 The three-wire control terminal (Xi) of this mode is designated for stopping. The operation command is generated by X1 (FWD operation) or X2 (REV operation), with both terminals governing the direction of operation.
  • Page 234: Version Change Log

    Version Change Log AC600 Series AC Drive Manual Version Change Log Date Version Content 2024.12 V1.0 First version issued...
  • Page 235 SUZHOU VEICHI ELECTRIC Co.,Ltd. Address:No.1000 Songjia road,Wuzhong Economic and Technological Development Zone,Suzhou Phone:+86-512-6617 1988 Official Website Facebook:https://www.facebook.com/veichiglobal/ Whatsapp:+86-138 2881 8903 Version: V1.0 E-mail:overseas@veichi.com Web:https://www.veichi.com/ Suzhou Veichi Electric Co.,Ltd.all rights reserved,subject to change without notice.