Compaq DL590 - HP ProLiant - 1 GB RAM Technology Brief page 9

Proliant dl590/64 server technology
Hide thumbs Also See for DL590 - HP ProLiant - 1 GB RAM:
Table of Contents

Advertisement

TC020702TB
T
B
ECHNOLOGY
RIEF
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
Figure 7: The ProLiant DL590/64 server uses a distributed power system.
. .
. .
. .
For each system power module plugged into the system, a corresponding primary power supply
. .
. .
must also be plugged in. This one-to-one relationship is required because each system power
. .
module depends on the fans in the corresponding primary power supply for cooling, and the
. .
. .
redundancy helps maintain availability.
. .
. .
The primary power supplies and their associated system power modules are N+1 redundant and
. .
. .
load balancing. When using high-line power, two of the primary power supplies can provide up to
. .
2500 watts of power—more than the 2 kilowatts required by a fully loaded ProLiant DL590/64
. .
. .
server. The third power supply provides redundancy in a fully configured system.
. .
. .
A lightly loaded ProLiant 590/64 server may operate satisfactorily using low-line power; however,
. .
if low-line power is used, redundancy of the power supplies may be sacrificed and the server
. .
. .
power demand may exceed the total amount of power available. Compaq strongly recommends
. .
using high-line power to operate ProLiant DL590/64 servers when possible.
. .
. .
. .
All of the power supplies and system power modules in the ProLiant DL590/64 server are hot
. .
pluggable, so a failed power supply in a redundant configuration can be replaced while the server
. .
. .
is up and running. Easy-to-use light-emitting diodes (LEDs) and levers simplify the identification
. .
and replacement of a failed power supply.
. .
. .
The ProLiant DL590/64 server has a built-in AC transfer switch that provides AC line redundancy.
. .
. .
This feature allows the server to operate from either of two independent AC power sources. If a
. .
second AC power source is present and connected, the server will automatically switch to the
. .
. .
second AC source if the primary source fails. The server will automatically switch back to the
. .
primary source as soon as it returns to its specified limits of operation. The AC line redundancy
. .
. .
feature only functions with use of high-line power.
. .
. .
. .
Cooling
. .
. .
The high-performance Itanium processors, massive amounts of memory, and other components in
. .
. .
the ProLiant 590/64 server require unprecedented levels of power. As a result of this large power
. .
draw, heat generation is a critical issue that required careful consideration of server cooling and
. .
. .
airflow.
. .
. .