WebPAM User Manual
If any bad sectors are found, they are listed here. WebPAM informs you by popup
and email messages when a bad sector error is logged (see page 38).
After 10 bad sectors have been discovered on a physical drive, WebPAM issues
a warning to replace the drive.
After 20 bad sectors have been discovered:
•
On fault-tolerant (RAID 1, 5 or 10) logical drives, the FastTrak controller will
set down the physical drive (take it offline) and the logical drive will go
critical.
Replace the physical drive and rebuild your logical drive.
•
On non-fault-tolerant (RAID 0) logical drives, the physical drive remains
online.
Backup your data, replace the physical drive, create a new logical drive and
copy your data to it.
See "Logical Drive Rebuild" on page 71 and "Logical Drive Critical / Offline" on
page 79.
See the FastTrak User Manual and SuperSwap User Manual for more
information about replacing a physical drive.
Locate a Physical Drive
When it becomes necessary to access a physical drive installed in a SuperSwap
enclosure, this function will help you identify the physical drive you want. To
locate a physical drive:
1.
Click on the Physical Drive View
2.
Click on the Physical Drive
3.
Click on the Locate Drive tab in Management View.
icon in Tree View.
icon.
60