INSTRUCTIONS FOR USE
PRESSURE REDUCERS
With connectors
For Argon Plasma Coagulation
WA94041A
WA94042A
WA94043A
WA94044A
WA94045A
WA94046A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WA94041A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Olympus WA94041A

  • Page 1 INSTRUCTIONS FOR USE PRESSURE REDUCERS With connectors For Argon Plasma Coagulation WA94041A WA94042A WA94043A WA94044A WA94045A WA94046A...
  • Page 3: Table Of Contents

    Contents 1 General information ..............5 1.1 User instructions ..............5 1.2 Signal words ................5 1.3 Conventions throughout this document ........5 1.4 Manufacturer ................6 1.5 Reporting serious incidents ............ 6 2 Safety information ..............7 2.1 Intended use ................7 2.2 General warnings and cautions ..........
  • Page 5: General Information

    • If the required instructions for use are missing, immediately contact an Olympus representative. • Keep the instructions for use in a safe, accessible location. 1.2 Signal words The following signal words are used throughout this document.
  • Page 6: Manufacturer

    Elements in the graphical user interface can be: - buttons - menu items - dialog elements 1.4 Manufacturer Olympus Winter & Ibe GmbH Kuehnstr. 61 22045 Hamburg Germany 1.5 Reporting serious incidents If a serious incident occurs with the device, report it to the...
  • Page 7: Safety Information

    Safety information 2 Safety information 2.1 Intended use The pressure reducers are accessories and must only be used in conjunction with the compatible argon plasma coagulation unit APU-300. • Observe the instructions for use of the compatible argon plasma coagulation unit APU-300 (WA90004W, WA90004J, WA90004C) regarding: - Intended use - Contraindications...
  • Page 8 • Before use, inspect the pressure reducer for damage. Especially inspect the following: - The O-ring in the gas cylinder coupling screw (only for WA94041A, WA94042A, WA94045A). - The gas hose. • Do not use a damaged pressure reducer.
  • Page 9 Compatible pressure reducer Using an incompatible pressure reducer can result in injury to the user and the medical personnel. • Only use a compatible Olympus pressure reducer as mentioned in the chapter “Product description” on page 11. NOTICE No lubricants...
  • Page 10 Safety information NOTICE Supply pressure of an argon gas cylinder A supply pressure of the argon gas cylinder that exceeds 250 bar (3625 psi), as displayed on the pressure gauge of the pressure reducer, can damage the pressure reducer. • Make sure that the supply pressure does not exceed 250 bar (3625 psi).
  • Page 11: Product Description

    3 Product description 3.1 Scope of delivery • Before use, check that all items listed below are available. • Contact an Olympus representative or an authorized service center if any items are missing or damaged. - Pressure reducer with pressure sensor cable...
  • Page 12 Product description Symbol Explanation Symbol Explanation Follow instructions for use Fragile, handle with care Indicates the range of humidity CE marking indicating that the to which the medical device can device is in conformity with the be safely exposed applicable requirements set out in applicable European Union harmonisation legislation.
  • Page 13: Nomenclature

    3) Relief valve 4) Pressure gauge 5) Nut 6) Gas cylinder coupling screw (region specific) 7) O-ring (only for WA94041A, WA94042A, WA94045A) 8) Non-adjustable pressure regulating part 9) Pressure sensor cable 10) Retaining ring 11) Pressure sensor plug for APU-300 side...
  • Page 14: Region Specific Coupling Screws

    Depending on the country or region where the pressure reducer is used it distinguishes by the design of the gas cylinder coupling screw including the nut. 3.4.1 For southern and central Europe (not Italy) – WA94041A Figure 3.2 Pressure reducer with connector according to DIN 477-6 3.4.2 For northern Europe –...
  • Page 15 Product description 3.4.3 For the USA and the Americas – WA94043A Figure 3.4 Pressure reducer with connector according to CGA 580 3.4.4 For the UK and others – WA94044A Figure 3.5 Pressure reducer with connector according to BS 341-3...
  • Page 16 Product description 3.4.5 For Japan – WA94045A Figure 3.6 Pressure reducer with connector according to JIS B8246 3.4.6 For France – WA94046A Figure 3.7 Pressure reducer with connector according to ISO 5145 No. 4...
  • Page 17: Warranty

    Product description 3.5 Warranty Any warranty claims towards Olympus are forfeited if the user or unauthorized persons attempt repair or modification of the product. No warranty is provided for any damage due to misuse of the product.
  • Page 18: Installation And Deinstallation

    • Check all markings on the product for clear visibility. • Check the O-ring inside the gas cylinder coupling screw for damage (only for WA94041A, WA94042A, WA94045A). 4.2 Mounting the pressure reducer 1. Remove the protective cover from the argon gas cylinder.
  • Page 19: Dismounting The Pressure Reducer

    Installation and deinstallation 4.3 Dismounting the pressure reducer 1. Make sure that the cylinder valve is completely closed. 2. Make sure that the gas hose and the pressure sensor are disconnected from the APU-300. 3. Make sure that the remaining gas in the pressure reducer has been released completely.
  • Page 20: Annual Safety Check

    Details of the annual safety check are described in the maintenance manual for the APU-300. • Contact the local Olympus representative to make sure to have the latest version of the maintenance manual available. Alternatively, the pressure reducers can be sent to an authorized service center where the annual safety check is done.
  • Page 21: Repair, Shipment And Disposal

    6 Repair, shipment and disposal 6.1 Repair There is no repair service. • Do not send the product to Olympus for repair. • Do not attempt to repair or modify the product. 6.2 Shipment When sending products to an authorized service center note the following.
  • Page 22: Compatible Equipment

    Compatible equipment 7 Compatible equipment The pressure reducers are accessories and must only be used in conjunction with the compatible argon plasma coagulation unit APU-300. • Observe the instructions for use of the APU-300 regarding the compatible equipment.
  • Page 23: Technical Data

    Outlet pressure Operating pressure P2 ..........4 bar/58 psi Gas type ............Argon 4.8 (99.998%) Connection standard for cylinder outlet/pressure reducer inlet WA94041A ..............DIN 477-6 WA94042A ..............DIN 477-10 WA94043A ..............CGA 580 WA94044A ..............BS 341-3 WA94045A ..............JIS B 8246 WA94046A ............
  • Page 24 Technical data Storage conditions Temperature ........–25 to 60 °C (–13 to 140 °F) Relative humidity ............10 to 85% Transport conditions Temperature ........–25 to 60 °C (–13 to 140 °F) Relative humidity ............10 to 85%...
  • Page 28 W7514450_03 2019-05-21 © Copyright 2019 Olympus Winter & Ibe GmbH...

This manual is also suitable for:

Wa94042aWa94043aWa94044aWa94045aWa94046a

Table of Contents