Page 9
- Deliver this manual to the end user of this product. Keep this manual in a safe place until this product is discarded. - This manual does not contain the description of function codes or troubleshooting information. Read through this manual in conjunction with the FRENIC-VG User's Manual. Fuji Electric Co., Ltd. INR-SI47-1661-JE - 1 -...
Preface Thank you for purchasing our DeviceNet interface card "OPC-VG1-DEV." This card is used to control the FRENIC-VG from a DeviceNet master (e.g., PLCs of various manufacturers) via DeviceNet. This card has the following features. - Compatible with the FRENIC5000VG7 series - Compliant with the DeviceNet Specifications Volume 1 Release 3.12 and Volume 3 Release 1.12 (Passed conformance test revision CT24) - Supporting the inverter common format, AC Drive Profile...
Page 11
Installation and wiring • Before starting installation and wiring, turn OFF the power and wait at least five minutes for inverters of 22 kW or below, or at least ten minutes for those of 30 kW or above. Make sure that the LED monitor and charging lamp are turned OFF.
Disposal • Treat the interface card as an industrial waste when disposing of it. Otherwise injuries could occur. Others • Never modify the interface card. Doing so could cause an electric shock or injuries. Chaper 1 BEFORE USE 1.1 Acceptance Inspection •...
1.3 Precautions for Use 1.3.1 Temporary storage Table 1.3-1 Storage and Transport Environments Item Specifications Storage temperature -25 to +70˚C Places not subjected to abrupt temperature changes or condensation (Note 1) or freezing. Relative humidity 5 to 95% (Note 2) The interface card must not be exposed to dust, direct sunlight, corrosive or flammable Atmosphere gases, oil mist, vapor, water drops or vibration.
Chaper 2 INSTALLING THE INTERFACE CARD 2.1 Removing the Front Cover • Incorrect handling in installation/removal jobs could result in a broken produce. • Before installing or removing the interface card, shut down the input power to the inverter and make sure that the charging lamp is turned OFF.
DeviceNet interface card. Please feel free to send your comments regarding any errors or omissions you may have found, or any suggestions you may have for generally improving the manual. In no event will Fuji Electric Co., Ltd. be liable for any direct or indirect damages resulting from the application of the information in this manual.
Need help?
Do you have a question about the DeviceNet OPC-VG1-DEV and is the answer not in the manual?
Questions and answers