Thank you for purchasing this PG interface card "OPC-PG3ID." Installing this card to your FRENIC-series enables to
provide motor control according to feedback signal from encoder (12V/15V/24V complementary or open-collector type).
Connect this PG interface card to the C-port on control board of FRENIC-series. Do not connect it to any other
port.
1. Acceptance inspection
(1) A PG interface card and two screws (M3 × 8) are
contained in the package.
(2) The PG interface card is not damaged during
transportation--no defective devices, dents or warps.
(3) The model name "OPC-PG3ID" is printed on the front of
the PG interface card as shown in Figure 1.1. (The "PG"
on the front is a short name, as shown in Figure 1.1.)
If you suspect the product is not working properly or if
you have any questions about your product, contact the
shop where you bought the product or your local Fuji
branch office.
2. Installation Procedure
Before starting installation and wiring, turn OFF the power and wait at least five minutes for inverters with a capacity of 22
kW or below, or at least ten minutes for inverters with a capacity of 30 kW or above. Make sure that the LED monitor and
charging lamp are turned OFF. Further, make sure, using a multimeter or a similar instrument, that the DC link bus voltage
between the terminals P(+) and N(-) has dropped to the safe level (+25 VDC or below).
Otherwise, electric shock could occur.
(1) Perform wiring on the PG interface card.
Refer to Section 4. "
TERM1 is the removable terminal. Use it with below precautions.
- Remove and connect the removable terminal after PG interface card is removed from inverter.
- Remove the removable terminal from the PG interface card by the tool (e.g. the straight slot screwdriver).
Otherwise, injuries could occur.
Failure may occur the PG interface card
(2) Remove the front cover from the inverter and expose the control printed circuit board (control PCB). The PG
interface card can be connected to the C-port only.
To remove the front cover, refer to the FRENIC-series Instruction Manual. For inverters with a capacity of 30 kW
or above, open also the keypad enclosure.
(3) Insert connector CN1 on the back of the PG interface card into the C-port on the inverter's control PCB. Then tighten
the two screws that come with the card.
Check that the positioning cutout is fitted on the tab and connector CN1 is fully inserted. Do not connect the PG
interface card to the ports other than C-port. Doing so may damage the card.
(4) If necessary, Please set change of the divided output with disconnection detection.
Refer to Section 8 "Setting."
Put the front cover back into place.
(5)
To put back the front cover, refer to the FRENIC-series Instruction Manual. For inverters with a capacity of 30
kW or above, close also the keypad enclosure.
PG Interface Card "OPC-PG3ID"
"
Wiring
Model name
Figure 1.1 Product Appearance.
Straight slot screwdriver
- 1 -
Instruction Manual
CN1
Terminal block TERM1
Option card
TERM1