Table 1-6. System Messages (continued)
Message
The amount of system
memory has changed
The file being copied
is too large for the
destination drive.
Time-of-day not set —
please run SETUP
program
Timer chip counter 2
failed
28
About Your System
Causes
Memory has been
added or removed, or a
memory module may
be faulty.
The file that you are
trying to copy is too
large to fit on the disk.
The time or date stored
in the System Setup
program does not
match the system
clock.
A chip on the system
board might be
malfunctioning.
Corrective Actions
If memory has been
added or removed, this
message is informative
and can be ignored. If
memory has not been
added or removed, check
the SEL to determine if
single-bit or multi-bit
errors were detected and
replace the faulty
memory module. See
"Troubleshooting
System Memory" on
page 114.
Try increasing disk space
on the destination drive
by deleting unnecessary
files.
Enter the System Setup
program and correct the
Date and Time options.
See "Using the System
Setup Program" on
page 31. If the problem
persists, see
"Troubleshooting the
System Battery" on
page 111.
Run the system
diagnostics. See
"Running the System
Diagnostics" on
page 127.