Introduction
Thank you for purchasing an Ion Technologies
sewage pump. Take the time to read the instructions
carefully before using this appliance. We strongly
recommend that you keep this instruction manual in a
safe place for future reference.
Check the nameplate for your pump's specification,
refer to the table list.
Be careful not to exceed the given specifications in
the use of your pump.
Each pump is individually factory tested to ensure
proper
performance.
instructions will eliminate potential operating problems
assuring years of trouble-free service.
Most accidents can be avoided by using common
sense.
Model
HP
SE40
4/10
SE60
6/10
www.ionprotects.com
Closely
following
these
0'
5'
110
105
165
148
OPERATION MANUAL
Dated: 02/13/2025
Document Name: SE40-SE60_OM
IMPORTANT: Ion Technologies is not responsible
for losses, injury or death resulting from failure to
observe these safety precautions, misuse, abuse
or misapplication of pumps or equipment.
Marks & Meanings
CAUTION: Keep the pump equipment out of
the reach of children! Warns that the failure to
follow the directions given could cause serious risk to
individuals or objects.
WARNING: This sign warns the operator that
the failure to follow an instruction may damage
the pump and/or the system.
Safety Warnings
CAUTION: Read these safety warnings first
before installing, servicing, or operating any
pump.
Before Installation
This manual contains important information for the safe
use of this product. Read this manual completely and
follow the instructions carefully. Reasonable care and
safe methods relating to the installation and operation
of this product should be practiced. Check local codes
and requirements before installation.
WARNING: Risk of Electrical Shock or
Electrocution. May result in serious injury or
death or fire hazard. Installer must disconnect all
electrical sources prior to installation, handling or
servicing. Only qualified personnel may install this
system. NFPA 70/National Electric Code (NEC) or
GPM @ Total Feet of Head
10'
95
125
Page 1 of 12
15'
20'
70
40
97
67
Maxium
Head
26
27

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ion Technologies SE40

  • Page 1 Introduction Safety Warnings Thank you for purchasing an Ion Technologies CAUTION: Read these safety warnings first sewage pump. Take the time to read the instructions before installing, servicing, or operating any carefully before using this appliance.
  • Page 2 Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 2 of 12 local codes must be followed. System must be properly CAUTION: All returned products must be grounded according to NEC. Do not lift pump by power cleaned, sanitized, or decontaminated prior cord.
  • Page 3 Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 3 of 12 Performance WARNING: Make sure lifting handles are securely fastened each time before lifting. CAUTION: Do not lift, carry or hang pump by the electrical cables. Damage to the electrical cables can cause shock, burns or death.
  • Page 4: Specifications

    Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 4 of 12 Important 1 Phase Models Model Number: MFG Date: Prior to installation, record Model Amps: Volts: Number, MFG Date, Amps, Phase: Voltage, Phase and HP, from pump nameplate for future reference.
  • Page 5: Pump Installation

    Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 5 of 12 Specifications (continued) Pump Installation Description: These important instructions must be followed for satisfactory performance of your pump. Before To pump domestic, commercial and light industrial...
  • Page 6: Pump Servicing

    Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 6 of 12 be closer than 2 inches from bottom of sump. See Discharge Piping Figure 1, Page 5. Install discharge piping or hose assembly to the pump.
  • Page 7: Troubleshooting

    Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 7 of 12 Thermal Protection The normally closed (N/C) over temperature sensor is embedded in the motor windings and will detect excessive heat in the event an overload condition occurs.
  • Page 8 Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 8 of 12 3. Pump is air-locked. Start and stop several 1. Inlet in pump base may be clogged. Remove times by plugging and unplugging cord. Check pump and clean out openings.
  • Page 9: Exploded View

    Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 9 of 12 Exploded View www.ionprotects.com...
  • Page 10: Exploded View Description

    Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 10 of 12 Exploded View Description Number Quantity Part Number Description 091SW4001 VOLUTE 091SW4002 O-RING 091SW4003 IMPELLER (SE40 Series) 091SW7503 IMPELLER (SE75 Series) 091SW4004 SHAFT SEAL...
  • Page 11 Ion Technologies SE40-SE60 OPERATION MANUAL Dated: 02/13/2025 Submersible Sewage Pump Document Name: SE40-SE60_OM Page 11 of 12 Notes www.ionprotects.com...
  • Page 12 Coverage and Term. Metropolitan Industries, Inc. (“Metropolitan”) warrants to the original purchaser (the “Buyer”) of each Ion Technologies product (the “product”), that any part thereof which proves to be defective in material or workmanship within one (1) year from date of manufacture, will be replaced at no charge with a new or remanufactured part, F.O.B.

This manual is also suitable for:

Se60Se60i

Table of Contents