Ion Technologies SEH50M-11 Operation Manual

Heavy duty high head sewage pumps

Advertisement

Quick Links

SEH50-SEH100-SEH200
Heavy Duty High Head Sewage Pumps
Introduction
Thank you for purchasing an Ion Technologies heavy
duty high head sewage pump. Take the time to read
the instructions carefully before using this appliance.
We strongly recommend that you keep this instruction
manual in a safe place for future reference.
Check the nameplate for your pump's specification,
refer to the table list.
Be careful not to exceed the given specifications in
the use of your pump.
Each pump is individually factory tested to ensure
proper
performance.
instructions will eliminate potential operating problems
assuring years of trouble-free service.
Most accidents can be avoided by using common
sense.
IMPORTANT: Ion Technologies is not responsible
for losses, injury or death resulting from failure to
observe these safety precautions, misuse, abuse
or misapplication of pumps or equipment.
www.ionproducts.net
Closely
following
these
OPERATION MANUAL
Dated: 03/22/2018
Document Name: SEH50-SEH100-SEH200_OM
Marks & Meanings
CAUTION: Keep the pump equipment out of
the reach of children! Warns that the failure to
follow the directions given could cause serious risk to
individuals or objects.
WARNING: This sign warns the operator that
the failure to follow an instruction may damage
the pump and/or the system.

Safety Warnings

CAUTION: Read these safety warnings first
before installing, servicing, or operating any
pump.
Before Installation
This manual contains important information for the safe
use of this product. Read this manual completely and
follow the instructions carefully. Reasonable care and
safe methods relating to the installation and operation
of this product should be practiced. Check local codes
and requirements before installation.
WARNING: Risk of Electrical Shock or
Electrocution. May result in serious injury or
death or fire hazard. Installer must disconnect all
electrical sources prior to installation, handling or
servicing. Only qualified personnel may install this
system. NFPA 70/National Electric Code (NEC) or
local codes must be followed. System must be properly
grounded according to NEC. Do not lift pump by power
cord.
WARNING: Risk of Fire or Explosion. Do not
smoke or use open flames in or around this
system. This system is not intended for use in
hazardous locations per NFPA 70 National Electric
Code. Do not pump flammable liquids. Consult factory
for optional equipment rated for hazardous location
use.
CAUTION:
amputation or severe lacerations can
result. Keep clear of suction and discharge
openings. DO NOT insert fingers into pump
with power connected. Risk of serious cutting or
Page 1 of 12
Rotating
machinery,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SEH50M-11 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ion Technologies SEH50M-11

  • Page 1: Safety Warnings

    Introduction of this product should be practiced. Check local codes and requirements before installation. Thank you for purchasing an Ion Technologies heavy duty high head sewage pump. Take the time to read WARNING: Risk of Electrical Shock or the instructions carefully before using this appliance.
  • Page 2 SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 2 of 12 amputation exists. Disconnect all power sources prior CAUTION: Rotating machinery, to servicing pump. Pump may start without warning. amputation or severe lacerations can result.
  • Page 3: Pump Installation

    SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 3 of 12 Performance CAUTION: These pumps are NOT to be installed locations classified hazardous in accordance with the National Electric Code, ANSI/NFPA 70. WARNING: Do not introduce into any sewer, SEH200 either directly, or through a kitchen waste disposal unit or toilet: Seafood Shells, Aquarium...
  • Page 4: Specifications

    Also record the voltage and current readings at startup. Amps L2-3: Volts L2-3: Amps L3-3: Volts L3-3: Specifications Nema Start Cord O.D. Model Volt Cord Size Cord Type Code Inches SEH50M-11 115/1 3450 12.0 16/3 0.43 SEH50M-21 230/1 3450 16/3 0.43 SEH50M-03 208/3 3450 16/4 0.46...
  • Page 5 SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 5 of 12 Specifications (continued) WARNING: Servicing should be performed only by an authorized service center. Description: Always disconnect the pump from power source To pump domestic, commercial and light industrial before handling or making any adjustments.
  • Page 6: Pre-Operation

    SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 6 of 12 Submergence Turn circuit breaker off before plugging or unplugging The pump should always be operated in the the switch and/or pump. submerged condition. The minimum sump liquid level It is recommended that the level control float should should never be less than above the pump’s motor, be set to insure that the liquid in the sump never...
  • Page 7: Troubleshooting

    SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 7 of 12 Troubleshooting motor to run slow, resulting in motor overload. Clear impeller. Pump does not run and/or just hums. Fuse blows or circuit breaker trips when pump 1.
  • Page 8: Exploded View Description

    SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 8 of 12 Exploded View Description Number Part Number Quantity Description 091SWH501 VOLUTE 091SWH502 IMPELLER 1/2 HP 091SWH102 IMPELLER 1.0 HP 091SWH202 IMPELLER 2.0 HP 091EP5003 SHAFT SEAL 091EP5003...
  • Page 9: Exploded View

    SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 9 of 12 Exploded View www.ionproducts.net...
  • Page 10 SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 10 of 12 Notes www.ionproducts.net...
  • Page 11 SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 11 of 12 Notes www.ionproducts.net...
  • Page 12 SEH50-SEH100-SEH200 OPERATION MANUAL Dated: 03/22/2018 Heavy Duty High Head Sewage Pumps Document Name: SEH50-SEH100-SEH200_OM Page 12 of 12 3 Year Residential Warranty Coverage and Term. Metropolitan Industries, Inc. (“Metropolitan”) warrants to the original purchaser (the “Buyer”) of each Ion® product (the “product”), that any part thereof which proves to be defective in material or workmanship within three (3) years from date of manufacture, will be replaced at no charge with a new or remanufactured part, F.O.B.

Table of Contents