Ipmi Configuration - Dell PowerEdge C6100 Hardware Owner's Manual

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge C6100:
Table of Contents

Advertisement

Option
Redirection After BIOS POST
(Always default)
Terminal Type
(VT100 default)
VT-UTF8 Combo Key
Support (Enabled default)
Terminal Display Mode
(Normal mode default)
NOTE:
When Flow Control is set to Software, the Hyper Terminal on remote side is
discontinued by pressing <Ctrl><S>. But the <Ctrl><S> is also the Setup Key Stroke
for setting onboard NIC PXE Option ROM Configuration. Therefore, we suggest
users change <Ctrl><S> to <Ctrl><B> in PXE OPROM Configuration in order to avoid
that the Hyper Terminal on remote side is discontinued when pressing <Ctrl><S>.

IPMI Configuration

Option
Status Of BMC
BMC Firmware Revision
View BMC System
Event Log
Description
Selects the settings for the redirection. This item
disappears when Remote Access is disabled:
• Disabled: turns off the redirection after POST.
• Boot Loader: redirection is active during POST and
boot loader.
• Always: redirection is always active. (Some
operating systems may not work if set to Always)
Selects the target terminal type. This item disappears
when Remote Access is disabled.
Enables or disables VT-UTF8 combination key
support for ANSI/VT100 terminals. This item
disappears when Remote Access is disabled.
Selects Terminal Display Mode.
Options:
• Normal Mode
• Recorder Mode
Description
Displays BMC status.
Displays BMC Firmware Revision.
Selecting this option and pressing Enter, displays:
Total Number Of Entries, SEL Entry Number,
SEL Record ID, SEL Record Type,
Event Time Stamp, Generator ID, Event Message
Format Version, Event Sensor Type, Event Sensor
Number, Event Dir Type, and Event Data.
Using the System Setup Program
49