POST Error Codes
Collecting System Event Log for Investigation
Error Messages are logged in the System Event Log (SEL). The SEL can be
accessed through system BIOS and the BMC setup for investigation. You can
also access SEL by browsing to the IP address of the BMC.
Code
Log in BMC Cause
0000h
Yes
0003h
Yes
0004h
Yes
0005h
Yes
000Bh
Yes
Timer Count Read/Write Error
CMOS Battery Error
CMOS Diagnostic Status Error
CMOS Checksum Error
CMOS Memory Size Error
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
See "Troubleshooting the
System Battery" on
page 118.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page 143.
About Your System
23
Need help?
Do you have a question about the PowerEdge C6100 and is the answer not in the manual?