ILX Lightwave LDC-3926 User Manual

Laser diode controller mainframe
Table of Contents

Advertisement

Quick Links

BUY – SELL – REPAIR – CALIBRATE
sales@simbol.ca
1-866-396-6248
Simbol Test Systems
is the one-stop shop for all your fiber optic test equipment and measurement
needs. As we are exclusively focused on e-commerce and international distribution of photonic
products since 2000, our customers rely on the
thousands of used and refurbished popular test equipment. They know they can get repair,
customization and calibration services from our laboratory for their own fiber optic instruments
from all renowned brand manufacturers.
If you wish to buy an ILX Laser Controller or control module or would consider another brand, visit
our catalog
here
to see our current stock with actual photos.
ILX LDC-3916, LDC-3908, LDC-3926 and all modules. Trust
the Simbol Test Systems expertise
With more than 20 years of expertise in repair of OSA, Tunable Lasers, Wavemeters, Laser
drivers and controllers, and many more, the quality of our services is renowned amongst the
service centers community and highly appreciated by our partners and customers. We developed
custom software allowing fast testing of Laser controllers racks and modules. Each module is
tested with a butterfly laser attached to it to ensure all its control functions are per specifications.
Each shelf is tested with a full load of modules. That is the only way to know a shelf can be used
at 100%. Don't settle for a two-page summary assessment to trust that your Laser Diode
Controller shelf or any Laser Control module is operating properly; our report contains the
complete table of all results, confirming it has really been tested. A report from other labs with
less data reflects a not completely calibrated unit. So be careful of other sellers saying their
equipment is "tested good", "powered on, self-tested", "pulled from a working environment". When
you choose AssetRelay, you can be confident that we actually test everything we sell so you know
it will work when it gets to your workplace.
Simbol Test Systems ILX Laser Controller modules and racks tests
The ILX LDC-3916, LDC-3908 and LDC-3926 mainframes sold by AssetRelay or Serviced by
Simbol Test Systems will go through a series of tests to ensure it meets or exceeds
manufacturer's published specifications. The equipment is shipped with a comprehensive
calibration/test report showing all performed and passed test. A dated calibration sticker is affixed
on the machine.
ILX LDC-3916, LDC-3908, LDC-3926 tests on report:
- Module Communication
- Front Panel Test
- Temperature Control
- Laser Power Control
Traceability: Instrumentation used during this calibration is traceable to N.I.S.T (National Institute
of Standards and Technology) or C.N.R.C. (Canadian National Research Council).
AssetRelay
catalog to find our stock listings of
- Interlock Test
- Full Load Test
- GPIB Interface Test

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDC-3926 and is the answer not in the manual?

Questions and answers

Summary of Contents for ILX Lightwave LDC-3926

  • Page 1 Simbol Test Systems ILX Laser Controller modules and racks tests The ILX LDC-3916, LDC-3908 and LDC-3926 mainframes sold by AssetRelay or Serviced by Simbol Test Systems will go through a series of tests to ensure it meets or exceeds manufacturer’s published specifications.
  • Page 2 User’s Guide Laser Diode Controller Mainframe LDC-3908 · · · 1-800-459-9459 · · ILX Lightwave Corporation P. O. Box 6310 Bozeman, MT, U.S.A. 59771 U.S. & Canada International Inquiries: 406-556-2481 Fax 406-586-9405 E-mail: support@ilxlightwave.com www.ilxlightwave.com 70031302__06_05...
  • Page 4: Table Of Contents

    Table of Contents List of Figures........... . v List of Tables.
  • Page 5 Table of Contents Maintenance ........... . . 5 Fuse Replacement .
  • Page 6 Table of Contents Chapter 3 Operating in Remote Control GPIB Configuration ..........19 Reading the GPIB Address .
  • Page 7 Table of Contents LDC-3908...
  • Page 8: List Of Figures

    List of Figures Figure 1.1 LDC-3908 Controller Front View ......4 Figure 1.2 LDC-3908 Controller Rear View ......5 Figure 2.1 Display Controls Menu .
  • Page 9 List of Figures LDC-3908...
  • Page 10: List Of Tables

    List of Tables Table 1.1 LDC-3908 Fuse Replacement ......6 Table 1.2 General LDC-3908 Specifications ......6 Table 3.1 Substitute Parameter Names .
  • Page 11 List of Tables viii LDC-3908...
  • Page 12: Safety And Warranty Information

    • Prolonged storage under adverse conditions • Failure to perform intended measurements or functions If necessary, return the instrument to ILX Lightwave, or authorized local ILX Lightwave distributor, for service or repair to ensure that safety features are maintained (see the contact information on page xii).
  • Page 13: Safety Symbols

    Technical specifications including electrical ratings and weight are included within the manual. See the Table of Contents to locate the specifications and other product information. The following classifications are standard across all ILX Lightwave products: • Indoor use only • Ordinary Protection: This product is NOT protected against the harmful ingress of moisture.
  • Page 14: Warranty

    Returning an Instrument If an instrument is to be shipped to ILX Lightwave for repair or service, be sure to: Obtain a Return Authorization number (RA) from ILX Customer Service. Attach a tag to the instrument identifying the owner and indicating the required service or repair.
  • Page 15: Comments, Suggestions, And Problems

    WA R R A N T Y Comments, Suggestions, and Problems To ensure that you get the most out of your ILX Lightwave product, we ask that you direct any product operation or service related questions or comments to ILX Lightwave Customer Support.
  • Page 16: Introduction And Specifications

    If any of the following symptoms exist, or are even suspected, remove the LDC-3916330 Series Module from service. Do not use the LDC-3926 until safe operation can be verified by trained service personnel.
  • Page 17: Initial Inspection

    I N T R O D U C T I O N A N D S P E C I F I C A T I O N S C H A P T E R Initial Inspection Initial Inspection When you receive your LDC-3908 Controller, verify that the following items were shipped with the instrument: •...
  • Page 18: Gpib Connector

    I N T R O D U C T I O N A N D S P E C I F I C A T I O N S C H A P T E R Front and Back Panels GPIB Connector The GPIB interface connector is located on the rear panel, directly to the left of the power input module.
  • Page 19: Figure 1.1 Ldc-3908 Controller Front View

    I N T R O D U C T I O N A N D S P E C I F I C A T I O N S C H A P T E R Front and Back Panels yourself with your new controller.
  • Page 20: Maintenance

    I N T R O D U C T I O N A N D S P E C I F I C A T I O N S C H A P T E R Maintenance Channel 1 GPIB Connector Modulation Input 15 Pin TEC Connector Channel 8...
  • Page 21: Table 1.1 Ldc-3908 Fuse Replacement

    I N T R O D U C T I O N A N D S P E C I F I C A T I O N S C H A P T E R Maintenance the fuse drawer and replace the fuse(s) with the appropriate type. Use only the fuses indicated below.
  • Page 22: Ldc-3908 Front Panel Controls

    C H A P T E R PERATIONS This chapter introduces you to the operation of the LDC-3908 eight-channel laser diode controller. It offers instructions for connecting your laser to the current source and temperature controller modules and describes powering up the instrument. The chapter also provides a description of the front panel controls, including both display and adjust controls.
  • Page 23: Hard Keys

    O P E R A T I O N S C H A P T E R LDC-3908 Front Panel Controls Hard Keys The menu structure is initiated using one of the primary Menu Control keys. These keys provide direct access to the Main and Channel menus as well as movement within the screens used most often for instrument control.
  • Page 24: Adjust Knob

    O P E R A T I O N S C H A P T E R Applying Power to the Laser Diode Controller Adjust Knob When the cursor in a menu is positioned on a parameter which can be adjusted, the Adjust Knob can be used to increase or decrease the parameter values.
  • Page 25: Using The Ldc-3908 Menu Structure

    Status Screen. Power down the instrument and check to see if the modules are correctly seated and fastened to the mainframe. If you continue to experience power up problems, power down the instrument and contact an ILX Lightwave Customer Service Representative.
  • Page 26: System Configuration

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure on, the display will indicate measured laser output current, LD forward voltage, measured temperature, thermoelectric module current, and sensor resistance. Figure 2.5 Channel Menu System Configuration The System Config.
  • Page 27: Display Configuration

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure Pressing the Up Arrow returns you to the Sys. Config. menu. Chapter 3 in both the Mainframe and Module manuals provides complete information on remote control operation.
  • Page 28: Calibration

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure function). Use the Adjust Knob or Adjust INC/DEC keys to change from off to on, or on to off. You must press Adjust Enter after making the desired selection in this menu to execute the change.
  • Page 29: All Channel Menu

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure To save a configuration: Select Sav/Rec from the System Configuration menu to access the Save/Recall Config. menu. Select the desired bin number using the Adjust Knob or the Adjust Up/Down Arrow keys. Press the Save soft key to save the configuration.
  • Page 30: Setting All Las

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure C with a temperature limit of 40o C and a gain of 30 in the 100 uA sensor range (for measuring temperatures between 10×...
  • Page 31: All Tec

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure 40oC. Next set the mode to T for constant temperature mode by scrolling down to the Mode field and setting it as described above.
  • Page 32: Mainframe Errors

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure measured temperature, if either of the outputs is active (LAS/TEC), and any errors respective to a channel. The up arrow soft key returns you to the Main menu. Figure 2.15 Status Menu Mainframe Errors Pressing the MF Errors soft key while in the Status menu displays the Mainframe Errors page.
  • Page 33: Status

    O P E R A T I O N S C H A P T E R Using the LDC-3908 Menu Structure Summary Menu Pressing the Summary soft key while in the Status menu displays the Summary page. Next to each channel number are the words LAS and TEC (if you have 3916370 Series Modules installed).
  • Page 34: Operating In Remote Control

    C H A P T E R PERATING IN EMOTE ONTROL Everything you learned to do from the front panel can also be done remotely and in some cases with more flexibility. For instance, in remote mode you have access to commands for functions not found on the front panel.
  • Page 35: Rs-232 Configuration

    O P E R A T I N G I N R E M O T E C O N T R O L C H A P T E R Remote Communication RS-232 Configuration Before you can operate the LDC-3908 over RS-232, you need to know its baud rate. The instrument's baud rate setting must match the baud rate used by the serial RS-232 interface, which is typically a serial Comm port on your PC.
  • Page 36: Gpib Versus Rs-232 Communication

    O P E R A T I N G I N R E M O T E C O N T R O L C H A P T E R LDC-3908 Laser Diode Controller Command Set GPIB Versus RS-232 Communication The LDC-3908 should not be run remotely via GPIB and RS-232 at the same time.
  • Page 37: Ieee 488.2 Common Commands

    "0" is returned. The *TST? query returns "1" if all LDC-3926 modules that were working at power-up (or at the time of the last *TST? query) have responded to the LDC-3908 mainframe within the past 15 seconds. If any modules fail to respond to the mainframe, *TST? returns "0", and those modules are no longer...
  • Page 38: Ldc-3908 Mainframe Specific Commands

    O P E R A T I N G I N R E M O T E C O N T R O L C H A P T E R Status Reporting A list of all of the IEEE 488.2 Common Commands supported by the LDC-3908 follows. *CAL? *CLS *ESE...
  • Page 39: Operation Complete Definition

    O P E R A T I N G I N R E M O T E C O N T R O L C H A P T E R Status Reporting Figure 3.1 on page 24 shows the status reporting scheme of the LDC-3908 Laser Diode Controller. Operation Complete Definition Bit 0 of the Standard Event Status register contains the status of the Operation Complete flag.
  • Page 40: Error Messages

    O P E R A T I N G I N R E M O T E C O N T R O L C H A P T E R Error Messages Error Messages In the event of a hardware error condition, error messages will be displayed on the channel menu screens.
  • Page 41 O P E R A T I N G I N R E M O T E C O N T R O L C H A P T E R Error Messages Table 3.3 LDC-3908 Mainframe Error Message Codes Error Code Explanation E 711...
  • Page 42: Table 4.1 Ldc-3908 Mainframe Device-Dependent Commands

    C H A P T E R OMMAND EFERENCE This chapter is a guide to all of the mainframe device-dependent commands for the LDC-3908 Laser Diode Controller. The chapter is divided into two parts. The first contains an overview of the remote commands used by the LDC-3908, as shown below in Table 4.1.
  • Page 43: Command Reference

    C O M M A N D R E F E R E N C E C H A P T E R Table 4.1 LDC-3908 Mainframe Device-Dependent Commands NAME PARAMETERS FUNCTION TERM Adds a carriage return to the device terminator. TERM? NONE Returns the status of the TERM command.
  • Page 44: Ldc-3908 Mainframe Command Reference

    C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference LDC-3908 Mainframe Command Reference This section presents the mainframe device-dependent commands for both local and remote operation of the LDC-3908 Laser Diode Controller, listed in alphabetical order.
  • Page 45 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference ALLCOND? RONT ANEL EMOTE The ALLCOND? query returns the status summary of enabled conditions from each channel of the LDC-3908 Laser Diode Controller.
  • Page 46 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference ALLEVE? RONT ANEL EMOTE The ALLEVE? query returns the status summary of enabled events from each channel of the LDC- 3908 Laser Diode Controller.
  • Page 47 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference BEEP? RONT ANEL EMOTE The BEEP? query returns the enable status of the LDC-3908 Laser Diode Controller's beeper. Parameters None.
  • Page 48 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference CHECKSUM? RONT ANEL EMOTE The CHECKSUM? query returns an integer value which is the summation of all pertinent parameters of the present configuration.
  • Page 49 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference MENU RONT ANEL EMOTE The MENU command causes the front panel display to switch to the specified menu. Parameters An <nrf value>...
  • Page 50 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference MODIDN? RONT ANEL EMOTE The MODIDN? query returns the module's model name and serial number. Parameters None.
  • Page 51 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference RADix? RONT ANEL EMOTE The RADix? query allows the programmer to determine which radix type for status, condition, and event query response data is currently selected.
  • Page 52 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference TERM RONT ANEL EMOTE The TERM command allows the programmer to change the default (IEEE488.2 standard) terminator to include the carriage return.
  • Page 53 C O M M A N D R E F E R E N C E C H A P T E R LDC-3908 Mainframe Command Reference LDC-3908...
  • Page 54: Functions And Features

    C H A P T E R UNCTIONS AND EATURES This chapter introduces you to the following LDC-3908 functions: 1) Save and Recall feature; 2) external modulation of laser current. Saving and Recalling from the Front Panel For applications where you may need to alternate between particular instrument configurations, the LDC-3908 Controller offers a unique Save and Recall feature.
  • Page 55: Modulating The Controller Laser Current Sources

    FU N C T I O N S A N D FE A T U R E S C H A P T E R Modulating the Controller Laser Current Sources Modulating the Controller Laser Current Sources The LDC-3908 Laser Diode Controller allows a modulated signal to be superimposed on the Laser current of any or all current source modules.
  • Page 56: Index

    NDEX keypad 8 customer service contact information xii AC power 2, 9 adjust controls 8 adjust knob 9 all channel menu 14 default all LAS menu 15 GPIB address 19 all TEC menu 15 settings 14 ANSI/IEEE standard 488.2 6 definition operation complete 24 device-dependent commands 27...
  • Page 57 I N D E X humidity 6 condition 23 event 23 remote communication 20 RS-232 IEEE standard 488.2 6, 22 connectors 6 INC/DEC keys 9 RS-232 communication 21 RS-232 configuration 20 RS-232 connector 2 keypad 8 keys hard 8 save and recall 39 INC/DEC 9 save and recall menu 13 soft 8...

This manual is also suitable for:

Ldc-3908Ldc-3916

Table of Contents