Hitachi RPIZ-0.8FSN1Q Operation, Installation, And Maintenance Manual
Hitachi RPIZ-0.8FSN1Q Operation, Installation, And Maintenance Manual

Hitachi RPIZ-0.8FSN1Q Operation, Installation, And Maintenance Manual

Inverter -driven multi-split system heat pump air conditioner

Advertisement

Type
Low-Height
In-the-Ceiling
Type
Model
RPIZ-0.8FSN1Q(/P)
RPIZ-1.0FSN1Q(/P)
RPIZ-1.3FSN1Q(/P)
RPIZ-1.5FSN1Q(/P)
RPIZ-1.8FSN1Q(/P)
RPIZ-2.0FSN1Q(/P)
RPIZ-2.3FSN1Q(/P)
RPIZ-2.5FSN1Q(/P)
P00677Q
ORIGINAL INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RPIZ-0.8FSN1Q and is the answer not in the manual?

Questions and answers

Summary of Contents for Hitachi RPIZ-0.8FSN1Q

  • Page 1 Type Model RPIZ-0.8FSN1Q(/P) RPIZ-1.0FSN1Q(/P) RPIZ-1.3FSN1Q(/P) Low-Height RPIZ-1.5FSN1Q(/P) In-the-Ceiling RPIZ-1.8FSN1Q(/P) Type RPIZ-2.0FSN1Q(/P) RPIZ-2.3FSN1Q(/P) RPIZ-2.5FSN1Q(/P) P00677Q ORIGINAL INSTRUCTIONS...
  • Page 2 HITACHI HITACHI HITACHI...
  • Page 3: Important Notice

    To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. HITACHI's HITACHI's...
  • Page 4 Section2 Installation & Maintenance Manual...
  • Page 5 The appliance is not to be used by children or person with reduced physical, sensory or mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised that they do not play with the appliance.
  • Page 6 3.Unit Drawing & Function Key Definition Model:0.8 1.5 Model:1.8 2.5 Part Name Part Name Refrigerant Liquid Pipe Connection Fan Motor Float Switch Heat Exchanger Drain Pan Distributor Air Outlet Air Inlet Strainer Micro-Computer Control Expansion Valve Drain Discharge Mechanism Electrical Control Box Shift Joint ( 1 .
  • Page 7: Before Operation

    4. Before Operation   Regarding the instructions of Wired Remote Control Switch or Wireless Remote Control Switch, read the operation manual attached to the control switch.
  • Page 8: Troubleshooting

    7. Troubleshooting...
  • Page 9 R410A...
  • Page 12 for Suspension Bolt (unit:mm) Model 0.8~1.5 1.8~2.5...
  • Page 14 (unit:mm) (Units without drain pump) Refrigerant Liquid Refrigerant Gas Pipe Connection Pipe Connection Drain Pipe Connection field- (Units with drain pump) Refrigerant Gas Refrigerant Liquid Drain Pipe Pipe Connection Pipe Connection Connection Optional Optional Optional unit:mm(in.) Model 0.8~1.5 1.8~2 2.3~2.5 Flaring Dimension Perform the flaring work as shown below.
  • Page 15 Drain Pump(optional) (unit:mm) Standard...
  • Page 16 ± 6%...
  • Page 17 Electrical Box Cover Air Outlet Air lnlet Remove the fixing screws for electrical box cover PCB2 PCB1 Cord Clamp 220-240V~ /50Hz 220V~ /60Hz 0.8~2.5...
  • Page 18 Use an ELB (Electric Leakage Breaker).If not Use an ELB (Electric Leakage Breaker).If not used ,it will cause an electric shock or a fire. used ,it will cause an electric shock or a fire. Run through the cables using conduit tube, Run through the cables using conduit tube, and Completely seal the end of conduit tube and Completely seal the end of conduit tube...
  • Page 19 Ex.) Set at No.5 Cycle Set by inserting Setting DSW5 Slotted screwdriver Position into the groove Set All Pins OFF Before shipment. DSW5 and RSW2 are set to "0". RSW2 Max.64 cycles are available to set when all the equipment to be connected are corresponding to H-LINK.
  • Page 21 P00677Q 2015.11...

Table of Contents