Huawei Health Huawei Health Huawei Health...
Page 2
If you have any questions about this device, please call the customer service hotline. For details, visit https://consumer.huawei.com/en/support/hotline/. Warnings This device has not been validated for use on newborn babies or those who are pregnant.
Page 3
Consult with your physician before using this device if you are undergoing intravascular interven- • tion or treatment, or if you have an arteriovenous (A-V) shunt, as doing so may temporarily restrict blood flow and cause injury. Ensure that this device is not restricting blood flow by observing the arm when taking blood pres- •...
Page 4
This device comes with a non-removable battery. Do not try to replace or fix the battery within its • service life, as doing so may damage this device and/or cause injury. Do not use any accessories, transducers, or cables other than the ones specified or provided •...
Page 5
eclampsia, or kidney disease. Any of these conditions may affect the accuracy of blood pressure measurements. Moving or trembling during a blood pressure measurement may affect the accuracy of the mea- • surement. This device has been carefully tested. It can reach the required level of accuracy for blood pres- •...
After Bluetooth is disconnected, blood pressure measurements continue to work as normal, but the software version fails to update and data cannot be synced. 1.6 Performance Indicators Wrist Ambulatory Blood Pressure Monitor Name Models LCA-B10/LCA-B11...
Page 7
Software Component Release Version Bluetooth 4.0 or later Bluetooth Frequency range: 2.4 GHz (2402-2480 MHz) Wireless communication Modulation: GFSK, pi/4-DQPSK, pi/8-DPSK Effective radiated power: < 20 dBm Type of Protection Against Electric Internal power supply Shock Applied Parts Airbag and bottom cover (Classification type: Type BF) Level of Protection Against IP68 (The device provides the level of protection specified by the IP68 Penetration by Harmful Liquids or...
1.7 Structural Diagram and Packing List Up button Down button Strap (including the airbag) Notes: • The air vent is located where the device body and the strap meet. • Press the Down button to start a blood pressure measurement and press the Up button to stop it. Packing list: •...
1.9 Set Up Your Device 1. Use your phone to scan the QR code, or search for "Huawei Health" in AppGallery or on consumer.huawei.com to download the Huawei Health app.
Page 11
1.10 Measuring Your Wrist Circumference and Wearing the Device 1. Measure your wrist's circumference at about the width of two fingers away from the bottom of your palm. 2. Pull the tail of the measuring tool through the buckle on the head until it touches the arm to avoid being too tight, and record the number shown by the arrow.
2. Measuring Your Blood Pressure 2.1 Principles This device measures blood pressure via the oscillometric method. As the wrist strap (airbag) pressure increases, the pressure sensor in the device strap monitors and analyzes the pressure oscillations and automatically calculates your systolic and diastolic blood pressure and your pulse rate. 2.2 Your Surroundings Network Bluetooth 4.0 or later...
physiological conditions. To ensure the accuracy of your measurements, please make sure of the following: • Avoid eating, drinking alcohol, smoking, and exercising for at least 30 minutes before measuring your blood pressure. • Rest for 5 minutes before a blood pressure measurement and keep your body relaxed throughout the measurement.
Page 14
1. Enter the app list, select the Blood pressure app, and start a measurement. The device will then start to inflate automatically and it will display the pressure data on the screen in real time. You can also press the Down button to immediately start a blood pressure measurement.
Page 15
3. Once a measurement is complete, the device will automatically deflate and display the measurement result. ABPM XXX/XX XXXXXX XXXXXX Note: Measurement indicators include the 24-hour average value, daytime average value, nighttime average value, maximum value, minimum value, median, standard deviation, number of measurements, blood pres- sure load, coefficient of variation, nocturnal blood pressure dipping, and morning blood pressure surge.
Page 16
2.9 Measurement Irregularities and Solutions Fault Type Solution Measurement timeout If the fault persists after several attempts, contact an authorized Huawei service center. Inflation outside the If the fault persists after several attempts, contact an authorized Huawei service center. rated range...
• details, and other information related to the repairable parts of the device to the maintenance personnel designated by Huawei. If you have any questions about repairs or spare parts, contact an authorized Huawei service center. 3.1 Storing Your Device Store the device in a clean and safe place.
temperatures, dampness, dust, salt, chemicals, or corrosive gases. Avoid strong impacts, direct collisions, and exposure to sunlight or rain. • Storage and transportation conditions: Temperature: –20°C to +55°C Humidity: 10% RH to 95% RH (non-condensing) Atmospheric pressure: 80 kPa to 105 kPa Do not store the device in the following environments: Environments with water, high temperatures, dampness, direct sunlight, dust, or salt.
Page 19
Precautions When cleaning the device body and the strap (including the airbag), take care to ensure that no • liquid gets into the device. Do not immerse the watch body or strap (including the airbag) in water, and do not dry them by •...
Page 20
4. Symbols and Figures Figures and Symbols Description Type BF Applied Part Caution Indicates that the product is dust-proof and water-resistant. Indicates that the product is capable of being recycled. Short-distance radio technology, Bluetooth certification mark. Indicates that this device is endorsed by the Forest Stewardship Council, a non- profit NGO, which is committed to promoting sustainable forest management.
Page 21
Authorized representative in the European Union Manufacturer The temperature range that the device can safely tolerate The humidity range that the device can safely tolerate The atmospheric pressure range that the device can safely tolerate Serial number Model number Unique device identifier Date of manufacture How to wear the device properly Remove the packaging and dispose of it in the appropriate recycling bin...
August 2024. 5. Declaration of Electromagnetic Compatibility This device complies with the IEC 60601-1-2:2014/AMD1:2020 Electromagnetic Compatibility (EMC) standard. For details, please visit https://consumer.huawei.com/en/. Basic Performance At any point within the standard measurement range (temperature: 5°C to 40°C; relative humid- •...
Page 23
® The Bluetooth of such marks by Huawei Technologies Co., Ltd. is under license. Huawei Device Co., Ltd. is an affiliate of Huawei Technologies Co., Ltd. Other trademarks, product, service and company names mentioned may be the property of their respective owners.
Page 24
• To prevent possible hearing damage, do not listen at high volume levels for long periods. • Ideal operating temperatures are 5°C to 40°C. • Avoid placing metal objects on the surface of the wireless charging cradle, as they could cause the equipment to heat up and malfunction.
Page 25
Improper battery use may lead to fire, explosion, or other hazards. • Do not attempt to replace the battery yourself — you may damage the battery, which could cause overheating, fire, and injury. The built-in battery in your device should be serviced by Huawei or an authorised service provider.
Page 26
UK regulatory conformance Hereby, Huawei Device Co., Ltd. declares that this device LCA-B10/LCA-B11 is in compliance with the relevant statutory instruments in the UK. The full text of the declaration of conformity is available at the following internet address: https://consumer.huawei.com/certification.
Page 27
Limbs SAR: 0.08 W/kg EU regulatory conformance Hereby, Huawei Device Co., Ltd. declares that this device, LCA-B10/LCA-B11, is in compliance with the RED Directive 2014/53/EU, RoHS Directive 2011/65/EU, and MDR Regulation 2017/745/EU. The full text of the EU declaration of conformity, and most recent information about accessories & software are available at https://consumer.huawei.com/certification.
être affectée. Si vous avez des questions à propos de cet appareil, veuillez appeler le service clients. Pour plus d'informations, consultez le site https://consumer.huawei.com/en/support/hotline/. Avertissements • Cet appareil n'a pas été validé pour une utilisation sur des nouveau-nés ou des femmes enceintes.
Page 29
temporairement la circulation sanguine et causer des blessures. • Assurez-vous que l'appareil n'entrave pas la circulation sanguine en observant le bras lors de la prise de la tension artérielle. • Ne mesurez pas la tension artérielle trop souvent, car des ecchymoses peuvent survenir si le flux sanguin est entravé.