Isolite LPDC2 Series Installation And Operating Instruction

Die-cast aluminum exit sign

Advertisement

INSTALLATION AND OPERATING INSTRUCTION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including
the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. Install in accordance with all national and local electrical codes.
2. Disconnect power at circuit breaker or fuse before installing or servicing the unit.
3. DO NOT mount in hazardous locations, near gas or near electric heaters.
4. DO NOT let power cords contact hot surfaces.
5. Equipment should be mounted in locations and at heights where it will not be readily subject
to tampering by unauthorized personnel.
6. DO NOT use accessory equipment not recommended by the manufacturer. The use of such
equipment may cause unsafe condition and will void the unit's warranty.
7. DO NOT use this equipment for other than it's intended purpose.
8. All servicing should be performed by qualified personnel only.
9. Allow battery to charge for 24 hours before first use.
10. For indoor use only, unless WL (Wet Location) option is selected.
LPDC2 FAMILY
DIE-CAST ALUMINUM EXIT SIGN
SAVE THESE INSTRUCTIONS
31 Waterloo Ave • Berwyn, PA • 19312 U.S.A
Telephone: (610) 647-8200 • Email: support@isolite.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LPDC2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Isolite LPDC2 Series

  • Page 1 9. Allow battery to charge for 24 hours before first use. 10. For indoor use only, unless WL (Wet Location) option is selected. SAVE THESE INSTRUCTIONS 31 Waterloo Ave • Berwyn, PA • 19312 U.S.A Telephone: (610) 647-8200 • Email: support@isolite.com...
  • Page 2: Installation Preparation

    INSTALLATION OF FIXTURE TO SPIDER PLATE Attach power plug to power receptacle and push back into the fixture. Fasten fixture to spider plate with supplied countersunk screws. 2 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 3 APART. REPEAT ON ALL SIDES BEFORE PULLING APART. FIGURE 4: Removing the Directional Indicators (Chevrons) To remove the directional indicators (chevrons, remove light guide assembly and diffusers and set aside. Support front cover and knocked out desired indicators. (2X) DIRECTIONAL INDICATORS (CHEVRONS) ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 4 INTERNAL OR EXTERNAL TO WALL NOT SUPPLIED WITH EXIT SIGN SPIDER PLATE MOUNTING REAR COVER, SNAP MOUNT MAIN FIXTURE RUN DIFFUSER (2X) 8-32 SCREWS SUPPLIED WITH J-BOX FRONT/REAR COVER W/ LEGEND, SNAP MOUNT CONTINUE TO NEXT PAGE 4 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 5 INNER LEGEND (TRAP) W/ KO CHEVRONS OUTER GASKET (2X) PLUGS (2X) PLUG ASSEMBLY O-RINGS PC COVER, (2X) PLUG ASSEMBLY WASHERS SCREW MOUNT (2X) PLUG ASSEMBLY SCREWS (2X) 8-32 SCREWS SUPPLIED WITH J-BOX (8X) PC COVER SCREWS ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 6 J-BOX CAN BE MOUNTED EITHER INTERNAL OR EXTERNAL TO WALL. STANDARD 4” J-BOX NOT SUPPLIED WITH EXIT SIGN SPIDER PLATE (2X) 8-32 SCREWS SUPPLIED WITH J-BOX CANOPY (2X) CANOPY SCREWS MAIN FIXTURE RING CANOPY CONDUIT NUT 6 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 7 FACES; CHANGE ACCORDINGLY PER USE CASE. STANDARD 4” J-BOX NOT SUPPLIED WITH EXIT SIGN SPIDER PLATE (2X) 8-32 SCREWS SUPPLIED WITH J-BOX CANOPY GASKET CANOPY CANOPY O-RING (2X) CANOPY SCREWS MAIN FIXTURE RING CANOPY CONDUIT NUT ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 8 NOT SUPPLIED WITH EXIT SIGN CHANGE ACCORDINGLY PER USE CASE. J-BOX CAN BE MOUNTED EITHER INTERNAL OR EXTERNAL TO WALL. SPIDER PLATE (2X) 8-32 SCREWS SUPPLIED WITH J-BOX CANOPY (2X) CANOPY SCREWS MAIN FIXTURE RING CANOPY CONDUIT NUT 8 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 9 NOT SUPPLIED WITH EXIT SIGN DEPENDENT ON NUMBER OF FACES; CHANGE ACCORDINGLY PER USE CASE. SPIDER PLATE (2X) 8-32 SCREWS SUPPLIED WITH J-BOX CANOPY GASKET CANOPY CANOPY O-RING (2X) CANOPY SCREWS MAIN FIXTURE RING CANOPY CONDUIT NUT ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 10 7. Secure the canopy to the spider plate by twisting it until it is tight. Ensure that the wires are not visible when observing the sign from the front face. 8. Snap the front panel into place to complete the assembly process. 10 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 11 STANDARD 4” J-BOX NOT SUPPLIED WITH EXIT SIGN SPIDER PLATE (2X) PENDANT SADDLE SCREWS (2X) 8-32 SCREWS SUPPLIED WITH J-BOX PENDANT CANOPY (2X) PENDANT CANOPY SCREWS PENDANT STEM PENDANT SADDLE PENDANT COUPLING MAIN FIXTURE RING CANOPY CONDUIT NUT ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 12 NOTE: REFER TO OUTDOOR SINGLE/DOUBLE FACE ASSEMBLY INSTRUCTIONS FOR FRONT/ REAR PANEL CONFIGURATION (NOT SHOWN) REPLACE STANCHION MOUNTING ADAPTER WITH CONDUIT ENTRY BUSHING (NOT SHOWN) FOR CONDUIT ENTRY USE CASES FRONT/REAR PANEL MUST BE REINSTALLED IN INVERTED ORIENTATION 12 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 13 LEDs for 5 minutes to check the lamp load and battery. The test will be performed only if the battery is fully charged. If not, the test will automatically reschedule. Charger function is monitored continuously. ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 14: Status Indicators

    Transfer System Failure Factory Service (ON / Pause) Red Three Blinks Charger Failure Factory Service (ON / Pause) Red Five Blinks Lamp Failure Check Remote Connection / Factory Service (ON / Pause) CONTINUE TO NEXT PAGE 14 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 15: Battery Replacement

    To install remote lamp (3.6V, 3W max - not shown), the option connector is installed similarly in the master sign as shown in (Figure 13). Terminate remote lamp leads to the option connector in mating pins labeled “Remote Lamp”. Remote Lamp max mounting height to be 11 feet or the equivalent. ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 16: Troubleshooting

    To reset the lamp failure status, remove the unit from the wall, disconnect the battery, wait 30 seconds, reconnect the battery, reinstall the unit onto the mounting plate. The lamp current calculation will be performed on the next function test. 16 ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 17 INTENTIONALLY LEFT BLANK ISOLITE    WWW.ISOLITE.COM REV-1  20250227...
  • Page 18 SAVE THESE INSTRUCTIONS 31 Waterloo Ave • Berwyn, PA • 19312 U.S.A Telephone: (610) 647-8200 • Email: support@isolite.com...

This manual is also suitable for:

Lpdc2 sdEm lpdc2